Animal environment in research: how to measure temperature, humidity and black globe in livestock buildings, calculate THI, BGHI and enthalpy and combine them with the weather station
A didactic guide to measuring the thermal environment in poultry houses, dairy barns and paddocks: why a thermometer alone is not enough, black globe temperature, air velocity, the THI, BGHI, radiant heat load and enthalpy indices (with local pressure), choosing a temperature and humidity logger and propagating its error, standard and alternative globes, installation, intercalibration, salt solutions, ammonia, quality control, a worked example, combining with the weather station and applications in Brazilian research.

Anyone who works with livestock knows that heat is expensive: the cow eats less and produces less milk, the broiler grows less and dies more, the lactating sow reduces feed intake and the piglet is weaned lighter. In much of Brazil, heat stress is the rule for several months of the year, not the exception. That is why animal environment (known in Brazil as ambiência), the study of how the environment inside livestock facilities affects the animal, has become a central topic in animal science, agricultural engineering and veterinary medicine.
The problem is that many animal-environment studies are weak precisely in the part that looks simplest: the measurement. A thermo-hygrometer hanging on the central pillar and read twice a day does not describe the environment the animal feels. Missing are the thermal radiation from the roof and the sun, the air velocity, the variation across space and the outdoor reference that allows you to say whether the building improved or worsened the climate.
This guide explains, in classroom language, how to measure air temperature, humidity, black globe temperature and air velocity inside livestock facilities with data loggers, how to turn these measurements into the most widely used indices (THI, BGHI, radiant heat load and enthalpy), which instrument and installation errors distort these indices the most, and how to combine the indoor series with the weather station to evaluate the facility properly. It is written for lecturers, graduate students and technicians in animal science, veterinary medicine, agricultural engineering and agronomy who are planning an experiment or reviewing data already collected.
If the measurement of air temperature and humidity is not yet clear, start with the guide Air temperature and humidity at the weather station: how to choose the sensor and the radiation shield. Here we apply those principles to poultry houses, dairy barns, pens and paddocks.
Why a thermometer alone is not enough
A homeothermic animal exchanges heat with its environment through four pathways: conduction (with the floor and bedding), convection (with the air flowing over skin or feathers), radiation (with the sun, the sky, the roof, the walls and the ground) and evaporation (sweating and panting). Each pathway depends on a different variable:
- convection depends on air temperature and air velocity;
- radiation depends on the radiant temperature of the surrounding surfaces and on solar radiation;
- evaporation depends on air humidity: the more humid the air, the less heat the animal can lose by sweating or panting.
There is a range of conditions, called the thermoneutral zone, in which the animal keeps its body temperature with minimum energy expenditure. Above it, the animal starts spending energy and changing behavior to lose heat, and production drops. The limits of this zone vary with species, breed, age, production level, acclimatization and body covering. For dairy cows, for example, a frequently cited review (West, 2003, as reported by Herbut et al., 2018) adopts roughly −0.5 to 20 °C, with relative humidity between 60 and 80%, far below the temperatures of a summer afternoon in central Brazil.
The practical consequence: two buildings with the same air temperature can impose very different heat loads, because one has a hot roof and still air while the other has good ventilation and cool shade. This is why animal-environment research uses indices that combine several variables.
The variables that must be measured
Air temperature and humidity
They are the basis of almost every index. From them you calculate the dew point temperature, the mixing ratio (grams of water vapor per kilogram of dry air) and the enthalpy. Inside buildings, humidity is usually higher than outside, because animals, bedding, drinkers and fogging release vapor. Measuring inside and outside allows you to quantify this addition.
Black globe temperature
The black globe thermometer is a thin, hollow sphere painted matte black, with a temperature sensor at its center. The sphere absorbs radiation from all directions and exchanges heat by convection with the air; at equilibrium, the temperature at the center (Tbg) summarizes the combined effect of air temperature, radiation and wind. Brought into agricultural research by Bond and Kelly (1955), the standard globe is 15 cm in diameter and made of copper; ISO 7726 describes the same instrument for human environments. Globe temperature is the variable that "sees" the hot roof and the sun entering from the side.
Air velocity
Needed to calculate the mean radiant temperature from the globe and to evaluate ventilation systems (tunnel ventilation, fans over the stalls, natural ventilation with curtains). In buildings, velocities are usually low and highly variable across space, which calls for attention to the lower limit of the chosen anemometer.
Outdoor solar radiation and wind
They do not enter most indoor indices directly, but they explain the heat load reaching the building, and so they come from the weather station. In pastures and paddocks without shade, solar radiation is the main heat source.
Gases
Ammonia and CO₂ do not enter thermal indices, but they affect the choice of humidity sensor (see below), and CO₂ is a good indicator of the ventilation rate; the guide on CO₂ with an NDIR sensor explains the corrections for this type of sensor.
Thermal comfort indices, one by one
Temperature-humidity index (THI)
THI was born as a "discomfort index" for people (Thom, 1959) and was adapted to animals. There are several forms in the literature. Two of the most widely used are:
THI = (1.8·Tdb + 32) − (0.55 − 0.0055·RH)·(1.8·Tdb − 26) (NRC, 1971 form)
THI = Tdb + 0.36·Tdp + 41.2 (dew-point form, attributed to Yousef, 1985)
where Tdb is the air (dry-bulb) temperature (°C), RH is relative humidity (%) and Tdp is the dew point temperature (°C). The two forms do not give exactly the same number for the same conditions, and some publications use slightly different constants. The rule is simple: report the equation used and do not compare values calculated with different equations.
Thresholds also vary. For dairy cows, the classification attributed to Hahn et al. (2009) uses THI < 74 normal, 75 to 78 alert, 79 to 83 danger and > 84 emergency; several studies adopt 72 as the threshold above which milk production starts to fall, and more recent work points to 68 (review by Herbut et al., 2018). For poultry and pigs, use the ranges proposed for the species and production phase.
THI has an important limitation: it does not see radiation or wind. A cow in the sun and another in the shade, in the same air, have the same THI.
Black globe-humidity index (BGHI)
To fix this limitation, Buffington et al. (1981) replaced air temperature with black globe temperature:
BGHI = Tbg + 0.36·Tdp + 41.5
In the original work, values below 70 did not significantly affect the cows, and above 75 feed intake began to drop (Herbut et al., 2018). BGHI is widely used in Brazil to compare roofing materials, shading and cooling systems, precisely because it responds to radiation.
Radiant heat load (RHL) and mean radiant temperature (MRT)
Globe temperature depends on wind: with more wind, the globe cools and approaches air temperature. To isolate the radiant part, we calculate the mean radiant temperature (MRT), the temperature of a uniform enclosure that would exchange the same radiant heat as the real environment. Esmay's form (1969), widely used in Brazilian animal-environment research, is:
MRT = 100·[2.51·√v·(Tbg − Tdb) + (Tbg/100)⁴]^0.25
with temperatures in kelvin and v in m/s. The radiant heat load is then RHL = σ·MRT⁴, with σ = 5.67 × 10⁻⁸ W m⁻² K⁻⁴. ISO 7726 gives an equivalent equation for a 15 cm globe under forced convection; both come from the same heat balance of the sphere and give very similar values. The key point is that RHL requires air velocity measured at the globe location.
Enthalpy
The enthalpy of moist air (h, in kJ per kg of dry air) adds up the sensible and latent heat contained in the air. From classical psychrometrics:
h = 1.006·Tdb + w·(2501 + 1.86·Tdb), with w = 0.622·e / (P − e)
where w is the mixing ratio (kg of vapor per kg of dry air), e is the partial vapor pressure and P is the local atmospheric pressure. Enthalpy is widely used in Brazilian poultry production, with tables of comfort ranges by bird age. Rodrigues et al. (2011), from ESALQ/USP, showed that equations and tables that ignore atmospheric pressure are not suitable for every region and proposed an equation that includes local pressure. Because pressure falls with altitude, the same temperature-humidity pair has higher enthalpy in Brasília or southern Minas Gerais than on the coast (see the worked example below). This is where the station barometer enters the calculation; the guide on atmospheric pressure at the weather station explains how to measure it.
More comprehensive indices
Some indices explicitly include wind and radiation, such as the adjusted THI of Mader et al. (2006) and the index of thermal stress for cows (ITSC), developed by researchers at UNESP for tropical environments with high solar radiation (Da Silva, Maia and Costa, 2015). They require more variables (including absorbed radiation and vapor pressure), but they show where the field is heading: measuring the complete physical environment, not just temperature and humidity.
A note on workers: WBGT
For people, the legal reference in Brazil is the WBGT (IBUTG in Portuguese) in Annex 3 of the NR-15 regulation, with the methodology of Fundacentro's NHO 06: WBGT = 0.7·Tnwb + 0.3·Tg in environments without direct solar load and WBGT = 0.7·Tnwb + 0.1·Tdb + 0.2·Tg outdoors with solar load. Tnwb is the natural wet-bulb temperature (a thermometer with a wet wick, without forced ventilation), which cannot be obtained directly from a temperature and humidity logger. If the project also evaluates farm workers, plan a separate WBGT meter.
Summary: what each index requires
| Index | Air temperature | Humidity | Black globe | Air velocity | Pressure |
|---|---|---|---|---|---|
| THI | yes | yes | — | — | — |
| BGHI | (for the dew point) | yes | yes | — | — |
| MRT and RHL | yes | — | yes | yes | — |
| Enthalpy | yes | yes | — | — | yes |
How to choose the temperature and humidity logger
For animal-environment work, the most common instrument is the standalone data logger: small, battery-powered, installed at several points in the building and downloaded during visits. The criteria that matter:
- Accuracy in the working range. Check the humidity accuracy between 20 and 80% RH and the temperature accuracy between 5 and 60 °C, and whether the manufacturer states the overall error (sensor plus resolution). Outside this range, especially above 80% RH, the error increases.
- Resolution. A resolution of 0.5 °C or 0.5% RH is enough for hourly means but limits the detection of small differences between treatments; in that case, prefer 0.1 resolutions.
- Memory and interval. Calculate the mission length: memory divided by the number of records per day. With 16 thousand readings per channel and a 10-minute interval (144 per day), memory lasts about 113 days.
- Chemical resistance. Poultry and pig houses have ammonia, dust and high humidity. Capacitive humidity elements can be contaminated by chemical vapors and lose calibration. There are probes designed for these environments, with PTFE encapsulation.
- Display. A display showing current, maximum and minimum values helps you check operation at each visit without connecting a computer.
- Standalone or wireless. Standalone loggers are cheap and robust, but only reveal a failure when downloaded. Wireless sensors, linked to a base station or the cloud, allow alarms and real-time monitoring, useful in long experiments or with animals at risk. The guide on weather station telemetry discusses range, data loss and power.
How sensor accuracy reaches the index
It is worth doing the math before buying. With a logger of typical accuracy ±0.55 °C and ±2.25% RH, under the conditions of this guide's worked example (30.2 °C and 58% RH at 91 kPa), propagating the errors through the equations:
| Index | Effect of ±0.55 °C | Effect of ±2.25% RH | Combined (quadrature) |
|---|---|---|---|
| THI (NRC, 1971) | ±0.8 | ±0.35 | ±0.8 |
| Enthalpy (kJ/kg) | ±2.0 | ±1.8 | ±2.7 |
| Dew point (°C) | ±0.5 | ±0.6 | ±0.8 |
An error of ±0.8 THI units is small compared with bands 4 to 5 units wide, but it is of the same order as the differences many experiments try to detect between treatments. That is why intercalibration between loggers (see below) matters more than the absolute accuracy of each one.
The black globe thermometer in practice
Standard or alternative globe
The 15 cm copper globe is expensive and hard to find. Brazilian research has tested alternatives: Souza et al. (2002), at UFV, compared PVC, aluminum and brass globes with the copper one and concluded that PVC globes of 15.0 and 11.5 cm offered the best cost-benefit ratio; Coelho et al. (2013) tested materials such as PET bottles and lamp globes and recommended correcting the values of the alternative globe before calculating BGHI and RHL. Sampaio et al. (2019) measured in a wind tunnel the thermal inertia of the 15 cm copper globe: about 24 minutes, with a hysteresis of about 28 minutes; smaller spheres respond faster, but cool more with wind.
Practical lessons:
- Use the same type of globe (material and diameter) in all treatments.
- If you use an alternative globe, compare it with a standard globe for a few days and fit a regression.
- Paint it matte black and repaint when it fades or accumulates dust.
- Because of the inertia, do not interpret one-minute values: use 10- to 30-minute means and avoid comparing instants right after abrupt changes (curtain opening, a passing cloud).
The sensor inside the globe
The sensor must sit at the center of the sphere, without touching the wall. A thermocouple connected to a thermocouple logger, an RTD connected to a transmitter, or a miniature button-type temperature logger suspended at the center all work well. Seal the cable entry so that it does not create an air inlet.
Where to install the globe
At the height of the animals' center of mass (roughly the back, for cattle; a few centimeters to a few tens of centimeters above the litter, for poultry), in a representative location, away from walls and point heat sources. If the goal is to compare roofs or shades, the globe must be under the shade the animal uses, and a second globe, in the sun, at the outdoor station, serves as the reference.
Planning and installing the loggers
Where and how many
Buildings are not homogeneous: there are gradients between air inlet and outlet in tunnel-ventilated houses, between the center and the sides, and between the area under the ridge vent and the area near the curtains. A single central point rarely represents the house. A common strategy is to place loggers on a regular grid (for example, three longitudinal lines by four or five cross-sections), which allows variability maps and geostatistical analysis. In experiments with treatments (roof types, shading, ventilation), use replicates and randomize positions, as in any experimental design.
Height and protection
- Height of the zone occupied by the animals, the same at every point.
- Shaded from direct radiation and protected from roof radiation. A dark-cased logger exposed to the sun, or just below a hot fiber-cement roof sheet, measures its own case. Use small ventilated radiation shields (stacked plates), as at a weather station; the guide on urban heat islands with a network of mini loggers discusses the shield effect in detail.
- Away from drinkers, foggers, heaters, lamps, brooders, fan outlets and walls.
- Out of the animals' reach: they peck, bite and rub. Wire-mesh cages or rigid brackets solve this.
- Protected from dust and splashes without blocking the sensor's air inlet; clean the openings at each visit.
Logging interval and clock
Intervals of 5 to 15 minutes are adequate for animal-environment work; the globe, with its inertia, does not justify shorter intervals. Synchronize all clocks on the same day, preferably with the same computer, and record whether time is local or UTC: INMET's automatic stations publish in UTC, and a three-hour error destroys any comparison of the daily cycle. Use the same interval as the station, or a divisor of it, to make the cross-analysis easier.
Air velocity
Measure air velocity next to the globe. Portable vane anemometers are practical for mapping tunnel ventilation, but many only start measuring at 0.3 to 0.5 m/s, which is exactly the range of naturally ventilated buildings. For low velocities, prefer thermal (hot-wire) or ultrasonic anemometers; the guide on wind measurement at the weather station compares the principles. If velocity is measured only in spot campaigns, state clearly in the methods how it was assigned to the continuous series.
Calibration, intercalibration and quality control
Before and after: all together
Before distributing the loggers, place all of them side by side, inside a radiation shield, next to a reference sensor (for example, the weather station's temperature and humidity sensor) for 24 to 48 hours, covering a full daily cycle. Repeat at the end of the experiment. This gives you, for each logger, the deviation from the reference and from the group mean, so you can correct the data or discard units that drifted.
Checking humidity with saturated salt solutions
Saturated salt solutions in a closed container produce known relative humidities that are almost independent of temperature. The classic values from Greenspan (1977), at 25 °C, are about 75.3% for sodium chloride and 32.8% for magnesium chloride. A test of a few hours in each solution, at stable temperature, shows whether the sensor is within specification at both ends of the useful range. It is not a traceable calibration, but it is an excellent check before and after a long campaign.
Ammonia, vapors and reconditioning
Manufacturers of loggers with capacitive sensors warn that the humidity element can be contaminated by chemical vapors and that materials with a strong odor should not be kept near the logger. For sensors exposed to extreme conditions or vapors, one manufacturer describes a reconditioning procedure: baking at 80 °C below 5% RH for 36 hours, followed by re-hydration at 20 to 30 °C above 74% RH for 48 hours, and warns that high levels of pollutants may cause permanent damage. In poultry and pig houses this means: check humidity before and after, compare with the reference and, if there is drift, recondition or replace. For long exposure to ammonia, consider probes with specific protection.
QC rules for the series
- Physical limits: humidity between 0 and 100%; temperature within a plausible range.
- Consistency between points: a logger that departs from the group for hours and then returns probably received sun or water, or was handled.
- Consistency with the station: at night, with the building open and ventilated, the indoor temperature should be close to the outdoor one. Large and constant differences indicate calibration or positioning errors.
- Absolute humidity: the indoor mixing ratio is usually equal to or higher than the outdoor one, because animals add vapor. Systematically lower indoor values suggest a humidity sensor error.
- Condensation: periods at 100% RH for hours, followed by an abrupt rise later, may be water on the sensor rather than real humidity.
- Documentation: record visits, cleaning, battery changes, management (curtain opening, fogging) and events with the animals.
From raw data to indices: step by step
- Apply the intercalibration corrections to each logger.
- Calculate the dew point from Tdb and RH, for example with the Magnus formula using the coefficients of Alduchov and Eskridge (1996): γ = ln(RH/100) + 17.625·T/(243.04 + T) and Tdp = 243.04·γ / (17.625 − γ).
- Calculate the indices for each record, and only then average. The mean THI is not the THI of the means, because the equations are not linear (the same principle applies to the vapor pressure deficit discussed in the guide on greenhouse microclimate).
- Use the measured pressure (or, if missing, the pressure estimated from altitude) in the enthalpy.
- Summarize in a biologically useful way: besides means, count hours per day above the adopted threshold and the duration of critical periods. Dairy studies associate milk losses with the number of hours with high THI on the previous day (Linvill and Pardue, 1992, as reported by Herbut et al., 2018). The night matters too: if THI does not fall below the threshold during the early morning hours, the animal does not recover.
Worked example (illustrative values)
Imagine a covered dairy barn with fans, on an experimental farm at about 900 m altitude. At 3 p.m., the weather station next to it records (illustrative values): air at 31.0 °C, 50% RH, pressure of 91.0 kPa, wind of 2.0 m/s, and a black globe installed in the sun at the station reads 41.0 °C. Inside the barn, at the height of the cows' backs, the logger reads 30.2 °C and 58% RH, the globe in the shade reads 31.5 °C and the anemometer indicates 1.2 m/s.
| Quantity | Outside (station, in the sun) | Inside (barn, in the shade) |
|---|---|---|
| Dew point | 19.4 °C | 21.0 °C |
| Mixing ratio | 15.7 g/kg | 17.5 g/kg |
| THI (NRC, 1971) | 79.6 | 79.8 |
| THI (dew-point form) | 79.2 | 79.0 |
| BGHI | 89.5 | 80.6 |
| MRT | 66.4 °C | 34.6 °C |
| RHL | 754 W/m² | 509 W/m² |
| Enthalpy | 71.5 kJ/kg | 75.1 kJ/kg |
What the table teaches:
- THI hardly changed (79.6 outside and 79.8 inside): the roof slightly reduced the temperature, but humidity increased. Anyone evaluating the barn by THI alone would conclude it is useless.
- BGHI fell by about 9 units and RHL by about 245 W/m²: the main benefit of the roof is cutting radiation, and only the globe sees that.
- The mixing ratio rose by 1.8 g/kg inside the barn: this is the vapor added by the animals and the floor. With fogging, the increase will be larger, and enthalpy shows whether evaporative cooling is really reducing the energy of the air.
- Air velocity weighs on RHL: with the same 31.5 °C globe, but 0.3 m/s instead of 1.2 m/s, the calculated MRT drops from 34.6 to 33.1 °C. Without the wind measurement, RHL is undetermined.
- Pressure weighs on enthalpy: the same indoor conditions (30.2 °C and 58% RH) would give 70.5 kJ/kg at sea level (101.3 kPa) and 75.1 kJ/kg at 91 kPa. A difference of 4.7 kJ/kg is enough to change the classification in comfort tables. Use tables and equations consistent with local pressure.
- The two THI forms differ by up to 0.8 units for the same data, the same order as the sensor error. One more reason to report the equation.
Combining with the weather station
Without an outdoor reference, it is impossible to know whether the indoor environment is good or bad for that day. The weather station provides this reference, and the most useful combinations are:
- Indoor − outdoor difference. Calculate, for each interval, the difference in temperature, mixing ratio, THI and BGHI. It is the most direct way to measure the thermal efficiency of the building and to compare roofs, curtains, ventilation and fogging, because it removes the effect of a hotter or cooler day.
- Thermal lag. Heavy roofs and walls delay the indoor temperature peak relative to the outdoor one. Cross-correlation between the series shows this lag and indicates until what time of night the stored heat keeps affecting the animals.
- Solar radiation and wind. Solar radiation measured by the pyranometer explains roof temperature and indoor BGHI; outdoor wind explains natural ventilation. Regressions of the indoor environment against these variables allow predicting building performance on days that were not measured.
- Atmospheric pressure. Essential for enthalpy and for converting relative humidity into mixing ratio.
- A globe in the sun at the station. A black globe at the station (installed at the same height as the indoor globe, over grass) creates the outdoor radiant reference needed to compare natural tree shade, shade cloth and roofs in pasture-based and silvopastoral systems.
- Long series and forecasting. The station allows you to calculate outdoor THI and BGHI over years and relate them to farm production data; temperature and humidity forecasts allow anticipating critical days and triggering management.
- Common quality control. The same QC criteria used at the station apply to the indoor network. The guide on integrated weather stations and quality control provides the procedure, and the guide on how to choose a data logger helps standardize intervals and formats.
Applications in Brazilian research
- Broiler and layer production. Comparison of conventional and climate-controlled houses, tunnel ventilation, fogging and evaporative cooling; maps of temperature, humidity and enthalpy along the house; relationships with performance, mortality and egg quality.
- Dairy cattle. Evaluation of free-stall, compost barn, pasture shade and sprinkler and fan systems; THI and BGHI related to milk yield, rectal temperature and behavior.
- Beef cattle and integrated systems. Natural shade in silvopastoral and integrated crop-livestock-forest systems, with black globes under the trees and in open pasture.
- Pig production. Farrowing (the conflict between sow and piglet comfort), nursery and finishing; ammonia and high humidity call for resistant sensors and frequent checks.
- Small ruminants in the semi-arid region. Intense solar radiation and low humidity make the black globe and RHL more informative than THI.
- Teaching. A small set of loggers, a globe and an anemometer allows practical classes in rural buildings and bioclimatology with real data from the university farm.
Catalog example: temperature and humidity logger with display
In the HenSistemas catalog, the temperature and humidity data logger with USB and display (ref. EL-USB-2-LCD, EasyLog line by Lascar Electronics, United Kingdom) is a standalone temperature and relative humidity logger, with dew point calculated in the software. According to the product page and the manufacturer's datasheet (issue 04/2024):
- Ranges: −35 to +80 °C and 0 to 100% RH.
- Accuracy (overall error): 0.55 °C typical between 5 and 60 °C; 2.25% RH typical between 20 and 80% RH. The calculated dew point has a typical accuracy of 1.7 °C.
- Resolution: 0.5 °C and 0.5% RH.
- Long-term stability: less than 0.02 °C and 0.25% RH per year.
- Memory: 16,382 temperature and 16,382 humidity readings; interval selectable from 10 seconds to 12 hours.
- Display: cycles between the current reading and the maximum and minimum logged values, for temperature and humidity, with a button.
- Battery: 3.6 V lithium (½ AA), lasting up to 2 years at 25 °C with one-minute logging; the manufacturer recommends replacing it annually or before logging critical data.
- Protection: IP67 with the cap fitted, according to the manufacturer; dimensions of 126 × 25 × 22 mm.
- Software: EasyLog, free, to set up, download, graph and export the data.
Points that connect with this guide:
- Humidity accuracy applies between 20 and 80% RH. With fogging or at night, humidity exceeds 80%; treat those periods with caution and check the sensor with a salt solution.
- The 0.5 °C and 0.5% RH resolution is fine for means and hours above thresholds; for differences of a few tenths between treatments, use means of several loggers and intercalibration.
- The manufacturer warns about contamination of the humidity sensor by chemical vapors and describes the reconditioning mentioned above; with heavy ammonia, check before and after and consider dedicated probes.
- The case is dark: in the sun or under hot roofs, use a radiation shield.
- Memory lasts about 113 days at a 10-minute interval (57 days at 5 minutes), which covers a broiler flock or a summer.
The product page is consistent with the manufacturer's datasheet in the main specifications; it does not mention the protection rating, the dew point accuracy or the warning about chemical contamination, which are in the manufacturer's documentation. The HenSistemas team confirms the availability of a calibration certificate in the quotation.
Related products
- Ammonia-resistant wireless temperature and humidity probe: PTFE probe for aggressive environments such as poultry and pig farms; transmits to a base station, with real-time alarms.
- Wi-Fi temperature and humidity logger: periodically sends data over the Wi-Fi network to the cloud, useful when the building has network coverage and the experiment requires alerts.
- Button-type miniature temperature and humidity logger: small and inexpensive, it allows dense grids of points; needs protection from splashes.
- Button-type miniature temperature logger: can be suspended at the center of a black globe to record globe temperature.
- Thermocouple temperature logger: an alternative for the globe, with the thermocouple at the center of the sphere and the logger outside.
- Portable thermo-anemometer: vane anemometer for mapping air velocity in ventilated houses; mind the 0.4 m/s lower limit.
- Wireless CO₂ and temperature sensor: CO₂ is a practical indicator of the building's ventilation rate.
- Relative humidity and temperature sensor with SDI-12 output: weather-station sensor for the outdoor reference.
Checklist before installing (and before publishing)
- Which indices does the question require, and are all the necessary variables (including globe, wind and pressure) planned?
- Were the loggers intercalibrated side by side with a reference before and after the experiment?
- Was humidity checked with salt solutions, especially in environments with ammonia?
- Do the points cover the variability of the building, with replicates and randomized positions?
- Are all sensors at the height of the animal-occupied zone, protected from sun, hot roofs, water and animals?
- Is the globe the same in all treatments, and are the globe type and correction used described?
- Was air velocity measured next to the globe, with an anemometer suited to the range?
- Are the clocks synchronized and is the time zone (local or UTC) documented?
- Does the weather station record temperature, humidity, pressure, radiation and wind at the same interval?
- Does the text report the equations used, the pressure adopted for enthalpy, the thresholds and how data above 80% RH were handled?
References
- Alduchov, O. A.; Eskridge, R. E. Improved Magnus form approximation of saturation vapor pressure. Journal of Applied Meteorology, v. 35, p. 601–609, 1996.
- Baêta, F. C.; Souza, C. F. Ambiência em edificações rurais: conforto animal. 2nd ed. Viçosa: Editora UFV, 2010.
- Bond, T. E.; Kelly, C. F. The globe thermometer in agricultural research. Agricultural Engineering, v. 36, p. 251–255, 1955.
- Buffington, D. E.; Collazo-Arocho, A.; Canton, G. H.; Pitt, D.; Thatcher, W. W.; Collier, R. J. Black globe-humidity index (BGHI) as comfort equation for dairy cows. Transactions of the ASAE, v. 24, n. 3, p. 711–714, 1981. DOI: 10.13031/2013.34325.
- Coelho, R. B.; Paula, M. O.; Ramirez, M. A.; Caetano, S. P.; Vieira, D. F. D. Nota técnica: estudo de materiais alternativos empregados na confecção do termômetro de globo negro utilizado para cálculo de ITGU e CTR. Engenharia na Agricultura, Viçosa, v. 21, n. 6, p. 597–604, 2013.
- Da Silva, R. G.; Maia, A. S. C.; Costa, L. L. M. Index of thermal stress for cows (ITSC) under high solar radiation in tropical environments. International Journal of Biometeorology, v. 59, n. 5, p. 551–559, 2015. DOI: 10.1007/s00484-014-0868-7.
- Esmay, M. L. Principles of animal environment. Westport: AVI Publishing, 1969.
- Fundacentro. NHO 06 — Avaliação da exposição ocupacional ao calor. São Paulo: Fundacentro.
- Greenspan, L. Humidity fixed points of binary saturated aqueous solutions. Journal of Research of the National Bureau of Standards, v. 81A, n. 1, p. 89–96, 1977.
- Herbut, P.; Angrecka, S.; Walczak, J. Environmental parameters to assessing of heat stress in dairy cattle — a review. International Journal of Biometeorology, v. 62, p. 2089–2097, 2018. DOI: 10.1007/s00484-018-1629-9.
- ISO 7726. Ergonomics of the thermal environment — Instruments for measuring physical quantities. Geneva: ISO.
- Lascar Electronics. EL-USB-2-LCD — Temperature, humidity and dew point data logger with LCD screen (datasheet, issue 04/2024).
- Brazilian Ministry of Labor. NR-15, Annex 3 — Heat (wording of Ordinance SEPRT No. 1,359/2019).
- National Research Council. A guide to environmental research on animals. Washington: National Academy of Sciences, 1971.
- Rodrigues, V. C.; Silva, I. J. O.; Vieira, F. M. C.; Nascimento, S. T. A correct enthalpy relationship as thermal comfort index for livestock. International Journal of Biometeorology, v. 55, n. 3, p. 455–459, 2011. DOI: 10.1007/s00484-010-0344-y.
- Sampaio, C. A. P.; Terezo, R. F.; Vassem Júnior, I.; Silva, L. M. C.; Borges, L. K. Hysteresis and thermal inertia of spheres of alternative materials for black globe thermometers. Engenharia Agrícola, v. 39, n. 5, p. 567–572, 2019. DOI: 10.1590/1809-4430-eng.agric.v39n5p567-572/2019.
- Souza, C. F.; Tinôco, I. F. F.; Baêta, F. C.; Ferreira, W. P. M.; Silva, R. S. Avaliação de materiais alternativos para confecção do termômetro de globo. Ciência e Agrotecnologia, Lavras, v. 26, n. 1, p. 157–164, 2002.
- Thom, E. C. The discomfort index. Weatherwise, v. 12, p. 57–59, 1959.
- HenSistemas product page: temperature and humidity data logger with USB and display.
Instruments for this application

Lascar ElectronicsEL-USB-2-LCD
EasyLog EL-USB-2-LCD Temp & RH Data Logger with USB and Display

Lascar ElectronicsEL-WiFi-TH
EasyLog EL-WiFi-TH WiFi Temperature & Humidity Data Logger

Maxim IntegratedDS1923-F5
DS1923-F5 Hygrochron Temperature/Humidity Logger

Maxim IntegratedDS1922L
DS1922L Thermochron iButton Temperature Data Logger, -40°C to +85°C

Lascar ElectronicsEL-USB-TC
EasyLog EL-USB-TC Thermocouple Temperature Data Logger with USB

AranetTDSPC005