Greenhouse microclimate in research: how to measure temperature, humidity and vapour pressure deficit (VPD) and compare it with the weather station
A teaching guide to measuring and documenting greenhouse and plastic-tunnel microclimate to research standards: why a weather station shield fails in still air (convection vs aspirated shield), how to read the sensor datasheet (0.4 °C; 4–6% RH; τ63% of 1 min), computing VPD with FAO-56 through worked examples (same dew point, three times the VPD; a sensor 2 °C too warm inflates VPD by 30%), installation at canopy height, gradient mapping for block designs, inside vs outside comparison with the weather station (transmittance, ΔT, ΔVPD), QC, maintenance and Brazilian studies from UFPel and ESALQ/USP.

Almost every agronomy, horticulture, plant pathology or plant biology department at a Brazilian public university has at least one greenhouse (glasshouse, plastic tunnel or screenhouse) where thesis experiments are run. And almost every examining committee has read the sentence “plants were grown in a greenhouse” — without a single temperature, humidity or radiation figure that would let another group reproduce the trial. A protected environment is not a controlled environment: it is a microclimate of its own, with gradients, peaks and humid nights that change plant physiology and disease incidence.
This guide is for professors, graduate students and technicians who want to measure and document greenhouse microclimate to research standards. We have already covered air temperature and humidity at the weather station and PAR and DLI. The angle here is different: what changes when the sensor sits under the plastic cover, how to compute and interpret the vapour pressure deficit (VPD), how to map gradients and how to compare the inside with the outdoor weather station.
Why a greenhouse needs its own measurements
Three physical differences separate protected cultivation from the open field:
- Little wind. With side walls and curtains closed, air speed near the plants drops sharply. That reduces heat and vapour exchange between leaf and air — and also the natural cooling of any sensor exposed to the sun.
- Altered radiation. The cover reflects and absorbs part of the solar radiation. In a plastic greenhouse on the UFPel campus (southern Brazil), Beckmann et al. (2006) measured a mean transmittance of 76% of global radiation over a tomato cycle; under 70% shading screens, Holcman & Sentelhas (2012), at ESALQ/USP, measured transmittances from 56.3% (no screen, polyethylene film only) down to 10.4% (black screen).
- Humidity builds up. Plant transpiration, substrate evaporation and irrigation release vapour into a small, poorly ventilated volume. At night, relative humidity easily climbs close to saturation.
The result is that the campus weather station does not describe the environment inside the greenhouse — not temperature, not humidity, not radiation. Holcman & Sentelhas (2012) installed an automatic micrometeorological station in each treatment for exactly this reason: under the blue screen, mean temperature was 1.3 °C above outside, with the largest humidity difference relative to outdoors.
The problem of a sensor in the sun with no wind
Every air thermometer actually measures the temperature of its own sensing element. In the sun it absorbs radiation and can only shed that heat to the air by convection. Outdoors, wind does that job; that is why weather station multi-plate shields are designed for wind-assisted ventilation. Inside a greenhouse, with almost still air, those same shields ventilate poorly and the sensor heats up.
There are three classic options:
- Aspirated shield (a fan forcing air over the sensor): this is the reference — the WMO Guide (WMO-No. 8) treats artificial ventilation as the most effective way to reduce radiation error — but it needs continuous mains power and fan maintenance.
- Shaded sensor (installed under the bench or between plants): solves heating, but measures a point that may not represent the canopy.
- Passive shield designed for still air, which uses its own heating to create airflow.
That third category is where the wireless temperature and humidity sensor with convection radiation shield for greenhouses (ref. EIC-TDSPT009, Aranet) fits. The vertical tube, about 66 cm long, works as a chimney: warmed air rises inside the tube and draws fresh air in from below, past the sensor. The manufacturer’s technical documentation explains the logic and also the limit: the chimney effect works well in a greenhouse, but outdoors the wind disrupts the chimney, and there wind-ventilated outdoor shields perform better. The teaching point: each shield for its own environment — do not use the greenhouse sensor as an outdoor reference, nor a weather station shield as a greenhouse sensor without comparing it first.
What the datasheet says — and how to read each number
From the product page on the website (consistent with the manufacturer’s datasheet for part number TDSPT009):
| Item | Specification | How to read it in research |
|---|---|---|
| Temperature range | −40 to 60 °C | Comfortably covers summer peaks under plastic. |
| Temperature accuracy | 0.4 °C (−10 to 60 °C) | Sensor error. Radiation error is handled by the shield. |
| RH range | 0 to 100% | — |
| RH accuracy | 4% RH (0–80% at 30 °C); 6% RH (80–95% at 30 °C) | The error grows precisely in the humid range, the most important one for disease and condensation. |
| Response time τ63% | 1 minute in still air (0 m/s) | Fast enough to capture curtain opening and misting events. |
| Recommended range for best accuracy | 20–80% RH (non-condensing) and 5–60 °C | Long periods above 80% may shift the reading, with slow recovery. |
| Transmission | 1, 2, 5 or 10 min (depending on base station firmware) | Shorter interval = more detail and less battery. |
| Radio range | up to 3 km line of sight | Inside metal structures and dense vegetation the real range is shorter: test it. |
| Power | 1 AA battery (alkaline or lithium) | No cable, no mains power. |
| Protection | IP68 | Withstands misting and washing. |
| Dimensions / weight | Ø 80 × 660 mm; about 230 g | Hung by a string. |
| Compatibility | Aranet base stations only (PRO or MINI) | The sensor does not log on its own: a base station is required. |
Two points deserve emphasis:
- RH accuracy degrades above 80%. In a greenhouse, the hours that matter most to a plant pathologist are nights above 90%. In that range, treat absolute RH with caution and prefer relative indicators (hours above a threshold, compared between treatments measured by the same intercalibrated sensor model).
- Battery life depends on the interval. The product page mentions “up to 7 years” in its summary and, in the table, up to 5 years with alkaline and up to 7 with lithium; the manufacturer’s original datasheet (2019) quotes up to 7 and 10 years respectively. The manufacturer’s newest generation details autonomy per measurement interval — at one reading per minute, life drops to just over a year with alkaline. Put battery changes in the experiment schedule.
VPD: the variable the plant “feels”
Relative humidity alone is misleading. It says how close the air is to saturation at that temperature, but not how strongly the air “pulls” water from the leaf. That driving force is the vapour pressure deficit (VPD):
- saturation vapour pressure (FAO-56, eq. 11): e°(T) = 0.6108 · exp[17.27 T / (T + 237.3)], in kPa;
- actual vapour pressure (FAO-56, eq. 54, for hourly data): eₐ = e°(T) · RH/100;
- VPD = e°(T) − eₐ.
Worked example 1: same absolute humidity, very different VPD
- Afternoon: 30 °C and 60% RH. e° = 4.24 kPa; eₐ = 2.55 kPa; VPD = 1.70 kPa. Dew point ≈ 21.4 °C.
- Morning: 25 °C and 80% RH. e° = 3.17 kPa; eₐ = 2.53 kPa; VPD = 0.63 kPa. Dew point ≈ 21.3 °C.
The air holds practically the same amount of vapour at both times (same dew point), yet afternoon evaporative demand is almost three times higher. It is VPD — not RH — that explains stomatal closure, early-afternoon wilting and differences in transpiration between treatments.
As a management reference, the review by Shamshiri et al. (2018) compiled recommendations for greenhouse tomato and shows that most sources indicate VPD between roughly 0.3 and 1.0 kPa, with values above 1.0 kPa associated with growth effects in some of the studies. Optimal ranges depend on species, stage and radiation: use the literature for your crop.
Worked example 2: how much a heated sensor distorts VPD
Suppose the real air is at 30 °C and 60% RH (VPD = 1.70 kPa), but a poorly shielded sensor heats up 2 °C in the sun. The vapour in the air is unchanged (eₐ = 2.55 kPa), but the sensor “sees” 32 °C and therefore a lower RH (≈ 53.5%). The computed VPD becomes 2.21 kPa — 30% above the true value. A shield error turns into false “water stress”. That is why the shield matters more than the sensor’s nominal accuracy.
Worked example 3: propagating the catalogue error
With the datasheet accuracies (0.4 °C and 4% RH) at 30 °C and 60% RH, VPD uncertainty is dominated by RH: 4% × 4.24 kPa ≈ 0.17 kPa, while 0.4 °C contributes only ≈ 0.04 kPa. Combined, ≈ ±0.17 kPa on 1.70 kPa (about 10%). For comparing treatments this is acceptable if all sensors are intercalibrated against each other before the trial (see QC).
Installation: where and how many sensors
- Canopy height. Install the sensor at the height of the active leaves (or just above the canopy) and raise it as the crop grows. Temperature near the roof can be several degrees higher than at bench level.
- Vertical, hanging. The convection shield relies on vertical airflow; do not lay it down or let it touch walls, metal frames or the plastic film.
- Away from local sources. Keep it away from heaters, fans, foggers, evaporative pads, doors and side walls, which create micro-environments that do not represent the useful area.
- More than one point. A greenhouse is rarely homogeneous: the side near the evaporative pad is cooler and more humid, the exhaust-fan side warmer; ends and sides differ from the centre. In research, use at least two to four points across the experimental area at the start of the project to map the gradient.
- Use the gradient in the design. If mapping shows a consistent temperature or VPD gradient along the structure, lay out blocks perpendicular to it (randomized complete block design). That is the noblest use of microclimate data: making the experiment statistically fairer.
- Radio. Before fixing the points, check each sensor’s signal quality at the base station; metal structures, screens and dense foliage attenuate the signal.
Logging: interval, clock and what to keep
- A 5-minute interval is a good compromise for most trials: it captures curtain opening, misting and the afternoon peak, and aggregates cleanly to hours and days. Use 1 minute only for fast-dynamics studies (misting control, for example), accepting the battery cost.
- Compute VPD and dew point from the raw T and RH of each interval — not from daily means of T and RH, because the relationship is non-linear.
- Log in UTC or declare the time zone. To compare with the outdoor station or with INMET (which publishes in UTC), time zones must match. See the step-by-step in integrated weather station on campus and comparison with INMET.
- Metrics that go into the paper: daily mean, minimum and maximum temperature; mean daytime VPD; hours per day with VPD above/below thresholds relevant to the crop; hours with RH above 90% (an indicator of leaf wetness and disease risk); accumulated degree-days; DLI (with a PAR sensor).
Inside vs outside: comparing with the weather station
Comparing with the outdoor station is not meant to “validate” the inside sensor — the environments are different on purpose. It serves to characterize the effect of the structure:
- Cover transmittance: τ = inside Rs / outside Rs (daily global radiation) or inside PAR / outside PAR. Example: 15 MJ m⁻² inside and 20 MJ m⁻² outside → τ = 0.75, the same order as the 76% measured by Beckmann et al. (2006). A progressive drop in τ over the months points to aged or dirty film — valuable information for managing the structure.
- Thermal elevation: ΔT = inside T − outside T, split into day and night. Clear days with closed curtains show the largest ΔT; at night the difference tends to be small.
- VPD difference: on dry winter days in central-southern Brazil, outdoor VPD can be high while inside, with irrigation and transpiring plants, it stays much lower; with ventilation open, the two converge.
- ET inside the greenhouse: FAO-56 ET₀ computed from outdoor data overestimates the inside demand (less wind and less radiation). If the goal is irrigation management, use data measured inside. See ET₀ with FAO-56.
Quality control (QC)
- Intercalibration before the trial. Place all sensors side by side, at the same shaded and ventilated spot, for 2 to 3 days. Compute each one’s bias relative to the group mean. Repeat at the end of the experiment. Differences between treatments smaller than the spread between sensors are not treatment differences.
- Physical limits. RH above 100%, negative VPD, jumps of several degrees between consecutive readings, or identical values repeated for hours: flag them.
- Condensation. Long periods above 95% RH may temporarily shift the sensor (the product page itself warns of slow recovery). Flag these periods and check that RH “returns” to coherent values on dry days.
- Day/night coherence. At night, without heating, inside temperature tends to stay close to outside; on clear nights, plastic greenhouses can even become colder than outdoors (thermal inversion, from radiative loss through the cover). If the inversion shows up in only one sensor, suspect its position (next to the film or a cold wall) rather than the weather.
- Coherence with management events. Curtain opening, misting and irrigation should show up in the series (T drop, RH rise). Record the date and time of every intervention in the field notebook.
- Annual check. Compare for a few days against a freshly calibrated reference hygrometer or a reference sensor in an aspirated shield.
Maintenance
- Monthly: inspect the shield tube (webs, insects, dust and pesticide residues alter airflow), confirm the sensor is still vertical and at canopy height, check signal and battery at the base station.
- At every crop change: clean the shield, reposition the points and redo a quick gradient mapping if the structure or management has changed.
- Batteries: replace according to the chosen transmission interval; prefer lithium in very hot environments or for short intervals.
- RH sensor: drift is unavoidable; schedule intercalibration and apply correction factors only when a traceable reference is available.
Featured product: wireless temperature and humidity sensor with convection shield for greenhouses
In the Hensistemas catalogue, the wireless temperature and relative humidity sensor for greenhouses (ref. EIC-TDSPT009, Aranet) combines:
- temperature (−40 to 60 °C; 0.4 °C accuracy between −10 and 60 °C) and relative humidity (0 to 100%; 4% RH up to 80%);
- a convection radiation shield in a vertical tube, designed for still-air greenhouses (τ63% of 1 minute at 0 m/s);
- wireless, battery-powered operation, with transmission every 1, 2, 5 or 10 minutes and up to 3 km line-of-sight range;
- IP68 housing;
- compatibility with the Aranet PRO and MINI base stations, which store the data; according to the manufacturer’s documentation, the system also provides dew point and VPD.
For research, the strong point is being able to spread several measurement points across the greenhouse with no cables and no mains power, with a shield suited to a low-wind environment. Points to plan for are the lower RH accuracy above 80%, the need for a base station, battery life depending on the interval and the fact that this shield is not the best choice for outdoor use.
Alternatives and complements from the catalogue
- Aranet PRO base station (ref. TDSBWPA2): receives up to 12, 50 or 100 sensors depending on the version, stores data locally for up to 10 years, sends e-mail alarms (SMS optional) and exports reports.
- Aranet wireless PAR light sensor (ref. TDSKAR01): PPFD and DLI inside the structure, to compute the PAR transmittance of covers and screens.
- Aranet wireless CO₂ and temperature sensor (ref. TDSPC005): 0 to 9999 ppm, ±(30 ppm + 3% of reading), IP67 — useful to record CO₂ depletion in a closed greenhouse and enrichment trials.
- Wireless soil/substrate moisture, electrical conductivity and temperature sensor (ref. EIC-TDSPHE01): closes the balance between atmospheric demand (VPD) and water available in the pot or bed; guide: soil moisture.
- Greenhouse monitoring with Aranet wireless sensors: overview of the line (T/RH, CO₂, PAR, substrate, plant weight and stem micro-variation) to build a complete network.
- Aranet IP68 wireless temperature and humidity sensor (ref. TDSPT801): no radiation shield, suited to spots without direct sun — growth chambers, germination rooms, under benches.
- Davis Vantage Pro2 Plus cabled weather station (ref. 6162C): outdoor reference for temperature, humidity, wind, rain and radiation to compute ΔT, ΔVPD and transmittance.
Checklist before using the data in your thesis
- Is the position (height and location) of each sensor documented and adjusted to crop growth?
- Were the sensors intercalibrated side by side before and after the trial?
- Is the shield suited to the environment (convection inside, wind ventilation outside)?
- Were VPD and dew point computed from each interval’s data, not from daily means?
- Were condensation periods (RH > 95%) flagged?
- Is there an outdoor series (weather station) in the same time zone to characterize transmittance and thermal elevation?
- Was the spatial gradient mapped and taken into account in the design?
- Does the field notebook record curtain, misting and irrigation management and battery changes?
References
- Aranet (SAF Tehnika). T/RH Sensor with Convection Shield — datasheet (TDSPT009), 2019.
- Aranet. T/RH sensors — technical documentation (Aranet Help, PRO series), including a comparison of shields in a greenhouse and outdoors.
- Hensistemas product page: wireless temperature and relative humidity sensor for greenhouses (ref. EIC-TDSPT009).
- Allen, R. G.; Pereira, L. S.; Raes, D.; Smith, M. Crop evapotranspiration — Guidelines for computing crop water requirements. FAO Irrigation and Drainage Paper 56. Rome: FAO, 1998.
- World Meteorological Organization. Guide to Instruments and Methods of Observation (WMO-No. 8), Volume I.
- Beckmann, M. Z.; Duarte, G. R. B.; Paula, V. A.; Mendez, M. E. G.; Peil, R. M. N. Radiação solar em ambiente protegido cultivado com tomateiro nas estações verão-outono do Rio Grande do Sul. Ciência Rural, v. 36, n. 1, p. 86–92, 2006. DOI: 10.1590/S0103-84782006000100013.
- Holcman, E.; Sentelhas, P. C. Microclimate under different shading screens in greenhouses cultivated with bromeliads. Revista Brasileira de Engenharia Agrícola e Ambiental, v. 16, n. 8, p. 858–863, 2012. DOI: 10.1590/S1415-43662012000800007.
- Shamshiri, R. R.; Jones, J. W.; Thorp, K. R.; Ahmad, D.; Che Man, H.; Taheri, S. Review of optimum temperature, humidity, and vapour pressure deficit for microclimate evaluation and control in greenhouse cultivation of tomato: a review. International Agrophysics, v. 32, n. 2, p. 287–302, 2018. DOI: 10.1515/intag-2017-0005.
Instruments for this application

AranetEIC-TDSPT009
Wireless Temp/HR Sensor for greenhouses

AranetTDSBWPA2
Aranet PRO

AranetTDSKAR01
Aranet Wireless PAR Light Sensor

AranetTDSPC005
Aranet CO2 and Temperature Sensor (IP67)

AranetEIC-TDSPHE01
Wireless Soil Moisture, CE and Temp Sensor

AranetAranet-Invernaderos-V3
Greenhouse Monitoring with Aranet Wireless Sensors

Davis Instruments6162C