Meteorology · Agriculture · Technical guides

Soil moisture in research: how to choose, install and calibrate the sensor

A teaching guide to soil moisture for researchers: volumetric versus gravimetric content, available water in mm, the dielectric principle and the Topp equation, TDR versus capacitance sensors, calibration in clay-rich tropical soils, installation without air gaps, SDI-12 integration with the weather station and a checklist.

By HenSistemas · · 14 min read

Handheld TDR sensor reader showing soil water content, temperature, permittivity and conductivity

Of all the variables a research station can record, soil moisture is the one that brings weather data closest to the plant. Rainfall tells you how much fell and evapotranspiration tells you how much the atmosphere demands, but it is the water content of the profile that shows how much was left for the roots. That is why it appears in irrigation management trials, water balance and recharge studies, the validation of crop models and satellite products, the ecophysiology of native species and the monitoring of slopes and catchments.

It is also the variable where the choice of sensor and, above all, the way it is installed weigh most on the result. This guide explains, step by step, what exactly is measured, how the main measuring principles work, why the clay-rich soils of Brazil and other tropical regions call for special attention to calibration, and how to plan installation and quality control so that the series has scientific value.

What is measured: water content, not "percent moisture"

There are two classic ways of expressing soil water:

  • Gravimetric water content (θg): mass of water divided by mass of dry soil, in g/g. It is what you get by weighing a sample before and after drying in an oven at 105 °C.
  • Volumetric water content (θv or VWC): volume of water divided by the total soil volume, in m³/m³ (or in %, which here means percentage points of volume). It is what electronic sensors estimate and what goes into water depth calculations.

The two are linked by bulk density: θv = θg × (ρb / ρw), where ρb is the dry bulk density of the soil and ρw the density of water. A soil with θg of 0.25 g/g and a bulk density of 1.2 g/cm³ has a θv of 0.30 m³/m³.

The advantage of volumetric content is that it converts directly into a depth of water. Every 0.01 m³/m³ in a 10 cm layer equals 1 mm of water. So if a soil's field capacity is 0.32 m³/m³ and its permanent wilting point is 0.18 m³/m³, available water is 0.14 m³/m³, or 140 mm per metre of soil; in a 20 cm root zone that is 28 mm. Calculations like this are how you decide when and how much to irrigate and how you close a water balance.

Content is not potential

A point that often confuses newcomers: water content tells you how much water is in the soil; matric potential (measured by tensiometers or granular matrix sensors) tells you how tightly it is held. The same θv can mean readily available water in a sandy soil and almost inaccessible water in a clay. The bridge between the two is the soil water retention curve, which should be determined in the laboratory for the soil of the experiment. In physiology or water stress work, consider measuring both quantities.

How sensors measure: the dielectric principle

Most modern sensors rely on relative dielectric permittivity (ε, or Ka). Liquid water has a permittivity close to 80; soil minerals between 3 and 5; air, 1. Because water dominates the signal, measuring the apparent permittivity of the soil is an indirect but very sensitive way of estimating water content.

The most widely used relationship is the empirical Topp equation, published in 1980:

θv = −0.053 + 0.0292·Ka − 0.00055·Ka² + 0.0000043·Ka³

For a soil with a measured permittivity of 17.3, for example, the equation gives θv ≈ 0.31 m³/m³, or 31%. It was fitted for medium-textured mineral soils and works well up to about 50% VWC; outside those conditions, manufacturers apply their own corrections.

TDR: the travel time of a pulse

In time domain reflectometry (TDR), the sensor sends a very fast electrical pulse along metal rods and measures how long it takes to travel out and back. The more water, the slower the propagation. Because permittivity is calculated from a time rather than from a voltage or current, the reading is little affected by the soil's electrical conductivity, that is, by salinity and fertiliser. This is the main advantage of true TDR. The technique once required an expensive bench instrument; today there are complete TDR sensors integrated into the probe itself, with a digital output to the data logger.

Capacitance and FDR: frequency and charge

Capacitance and frequency domain reflectometry (FDR) sensors form a capacitor with the soil and measure a change in frequency or charge. They are cheaper, use little power and allow compact designs such as profile probes inside access tubes. On the other hand, they tend to be more sensitive to electrical conductivity, temperature and soil contact, and the volume they measure is usually smaller and concentrated near the sensor surface. With a soil-specific calibration, they deliver excellent data for many purposes.

Resistance sensors

Gypsum blocks and simple resistance sensors measure the electrical resistance between two electrodes. They are useful as management indicators, but their response depends heavily on salinity and temperature and they are not well suited to quantitative research measurements.

Why calibration matters so much in tropical soils

The Topp equation and factory curves were developed largely with temperate soils. The Oxisols (Latossolos) and Ultisols (Argissolos) that cover much of Brazil are highly weathered, rich in clay and iron and aluminium oxides, with strong micro-aggregation. Several research studies in Brazil report deviations from generic curves in these soils, especially in very clayey textures, which reinforces the recommendation to calibrate in the soil of the experiment.

Even a high-quality TDR states an accuracy of about ±1 percentage point in coarse and medium-textured soils and ±2.5 points in fine-textured soils. For comparing treatments, that difference is usually small; for closing a water balance or estimating an irrigation depth, it already matters. The rule of thumb: the sensor gives excellent precision (repeatability and resolution), and calibration in your soil ensures accuracy.

A simple gravimetric calibration

  1. Install the sensor in representative soil or in a volume of soil packed to field bulk density.
  2. Over a drying cycle (or in batches at different moisture levels), record the sensor reading and collect undisturbed samples next to it with a volumetric ring of known volume.
  3. Weigh the wet samples, dry them in an oven at 105 °C to constant mass (usually 24 to 48 hours) and weigh them again.
  4. Calculate reference θv = (wet mass − dry mass) / ring volume, taking water density as 1 g/cm³.
  5. Fit a regression between the sensor reading (or raw permittivity, if the sensor provides it) and reference θv. Use at least 6 to 10 points from dry soil to near saturation.

Sensors that report permittivity in addition to VWC make this much easier, because calibration can be done directly on the physical quantity being measured.

Sampling volume, depth and replication

Each sensor "sees" a limited volume of soil around its rods, from a few millilitres to a few hundred millilitres. The larger the volume, the smaller the effect of a stone, a root or a macropore. Even so, the spatial variability of soil moisture is large: two identical sensors a few metres apart can differ by several percentage points.

Some guidance for experimental design:

  • Depths: follow the crop's root zone. For annual crops, combinations such as 10, 20, 40 and 60 cm are common; for perennials and forests, the profile may need to go beyond 1 m.
  • Replication: whenever possible, use more than one sensor per treatment or per depth. In water balance studies, the mean of several points is more robust than a single, very well calibrated point.
  • Position relative to the plant: in row crops, orchards and drip irrigation, the distance to the plant and to the emitter changes the reading completely. Record that position in the metadata.

How to install without spoiling the measurement

Most soil moisture errors are born at installation, not in the sensor.

  • Full contact: air pockets between the rods and the soil make the sensor read lower than the true value. Insert the rods into undisturbed soil, with a guide that keeps them parallel, and never wiggle the sensor once it is in.
  • Horizontal installation in a trench: dig a small trench to the desired depth, push the sensor horizontally into the sidewall with the rods in a horizontal plane, and backfill in layers, returning the soil in its original order and repacking it close to field density.
  • Preferential flow: do not let the cable or the trench become a channel that carries water faster to the sensor. Route the cable with a horizontal run before it rises, and protect it with conduit against rodents and machinery.
  • Stones and gravel: if a rod meets resistance, move to another spot rather than forcing it.
  • Settling time: in clay soils, the first days or weeks after installation, and the first rains, can show the backfilled soil settling. Take that period into account when analysing the data.
  • Cracking soils: in swelling clays, cracks that open on drying can pull the soil away from the rods and cause sudden drops in the reading.

Fixed, portable or wireless: which setup to choose

There is no single right sensor; there is the right setup for the research question.

  • Fixed sensor connected to a data logger: for continuous series at fixed points, such as weather stations, irrigation plots and water balance studies. A 15- or 30-minute interval is usually enough; after heavy rain or irrigation, shorter intervals reveal the wetting front.
  • Portable meter: for spatial variability, grid surveys, mapping management zones, greenhouse pots and sports fields. One person can take hundreds of georeferenced readings a day.
  • Profile probe: to follow several depths in a single tube, with a less destructive installation.
  • Wireless network: for many points in greenhouses, nurseries and block experiments, where running cables to a central logger would be impractical.

Electrical conductivity and soil temperature

Many moisture sensors also measure the soil's bulk electrical conductivity (EC) and temperature. Bulk EC responds to salinity, fertiliser and moisture itself, and is useful in fertigation and salinisation studies. Some instruments estimate pore water EC with models such as Hilhorst's; that value depends on assumptions about soil type and should be treated as an order-of-magnitude estimate, not a laboratory measurement. Soil temperature, in turn, feeds studies of germination, microbial activity and soil heat flux.

Integration with the weather station

When soil moisture is logged at the same station that measures rainfall, radiation, wind, air temperature and humidity, the data tell a complete story: water input, atmospheric demand estimated by the FAO-56 method and the response of the profile. To get there:

  • Prefer sensors with a digital output such as SDI-12, a three-wire serial protocol (power, ground and data) in which several sensors share the same cable, each with its own address. This simplifies wiring and avoids the accuracy loss of analogue outputs over long cables.
  • Check power consumption: sensors that wake up, read in a fraction of a second and go back to sleep allow operation on a battery and a small solar panel.
  • Synchronise clocks and use the same logging interval as the other variables, or a multiple of it.

Quality control of the series

A few simple checks prevent wrong conclusions:

  • Response to rain: after significant rain, the shallow sensor should respond before the deep one. If it does not, investigate contact or preferential flow.
  • Saturation ceiling: a sensor stuck for days at the same high value may be in a waterlogged layer, or in a pocket of water created by the trench itself.
  • Jumps and sudden drops: may indicate lightning, cable damage, rodents or soil cracking.
  • Consistency with the water balance: the sum of storage changes in the profile should be compatible with rainfall, irrigation and evapotranspiration over the period.
  • Metadata: record the installation date, actual depth, position, soil texture and bulk density, and any intervention. Without them, the series loses much of its value for publication.

An example from the catalogue

Acclima's TDR soil moisture sensor with SDI-12 interface (ref. TDR-315H on the product page) illustrates what we have discussed. It is a complete time domain reflectometer built into the probe, with three 15 cm stainless steel rods and a 10 m cable. It measures volumetric water content from 0 to 100%, permittivity from 1 to 80, bulk EC from 0 to 5000 µS/cm and temperature from −40 to +60 °C, and also estimates pore water EC with the Hilhorst model.

According to the manufacturer's data sheet, VWC accuracy is ±1 percentage point in coarse and medium-textured soils and ±2.5 points in fine-textured soils, with stability better than 1 point up to 4000 µS/cm bulk EC; temperature accuracy is ±0.25 °C. A reading takes about 0.25 s, the supply range is 3.5 to 15 V and idle current is below 10 µA, which suits battery operation. The form factor is designed for horizontal installation in a trench sidewall, with a guide that keeps the rods parallel.

For research, two details stand out. First, the sensor reports permittivity alongside VWC, which makes a specific calibration for Oxisols and other clay soils easier. Second, because the calculation comes from the pulse travel time, the moisture reading is little affected by changing salinity in fertigation experiments.

Related products

For the full picture, see also our guides How to choose a weather station, Tipping bucket rain gauge in research and Data logger: how to choose the right one.

Checklist before requesting a quote

  1. What is the research question: irrigation management, water balance, water stress, model or satellite validation? It defines the required accuracy, the number of points and the logging interval.
  2. Do you need continuous series at fixed points, spatial surveys, or both?
  3. What are the soil's texture and mineralogy? In very clayey soils, plan the gravimetric calibration from the start and prefer sensors that report permittivity.
  4. Which depths represent the root zone, and how many replicates does the budget allow?
  5. Is there significant salinity or fertigation? If so, prioritise TDR technology and EC measurement.
  6. Does the data logger read the chosen output (SDI-12, RS485 Modbus, analogue or wireless), and is there enough power on site?
  7. Who will handle installation, cable maintenance and metadata?

Answering these questions before the quote avoids discovering, after a whole season, that the sensor sat in an air pocket or that the factory curve underestimated the water in your Oxisol. If you would like help matching your research protocol to the catalogue, talk to the HenSistemas team.

Instruments for this application

Back to the blog