Meteorology · Agriculture · Technical guides

Tipping bucket rain gauges in research: how to measure rainfall and intensity you can trust

A teaching guide to tipping bucket rain gauges: resolution and intensity, typical errors per the WMO, siting per WMO and ANA, field checks and selection criteria for agricultural, hydrological and environmental research.

By HenSistemas · · 9 min read

Tipping bucket rain gauge installed in the field with a data logger on the mast

Rainfall looks like the simplest variable in a weather station: you just add up millimetres. In practice it is one of the hardest to measure well. Wind deflects drops, some water evaporates before it is counted, leaves clog the funnel and, in heavy storms, the sensor's own mechanism can no longer keep up with the water. For anyone working on water balance, irrigation, soil erosion or small-catchment hydrology, these details decide whether a data series is publishable or not.

This guide explains, in plain teaching language, how a tipping bucket rain gauge works, which errors it has, how to install it according to the World Meteorological Organization (WMO) and Brazil's National Water and Sanitation Agency (ANA), and what to check on the datasheet before buying.

How a tipping bucket rain gauge works

Water caught by a ring of known area runs down a funnel into a small seesaw with two compartments. When one compartment holds the amount of water it was calibrated for, its centre of mass passes the pivot, the bucket tips, empties that side and brings the other side into position. Each tip moves a magnet past a reed contact and produces an electrical pulse. The data logger counts pulses and multiplies them by the resolution (millimetres of rain per tip).

The arithmetic linking volume and millimetres is simple: 1 mm of rain equals 1 g of water per 10 cm² of collecting area. On a 400 cm² collector, 1 mm is therefore 40 mL; with a 0.2 mm resolution, each tip represents 8 mL of water. Keep this relationship in mind: it is the basis of the field check described below.

Because it produces a clean digital pulse, the tipping bucket became the standard rain sensor for automatic weather stations. In the automatic station network of INMET, Brazil's national weather service, for example, the rain gauge sits outside the main mast but inside the station's grassed enclosure.

Resolution and intensity: what changes in your analysis

Resolution sets the smallest increment recorded. The WMO recommends that, for detailed records, each tip should not exceed 0.2 mm. This has a consequence that is often forgotten: with 0.2 mm per pulse, intensity calculated over 1-minute windows can only change in steps of 12 mm/h. If your study depends on intensity rather than just daily totals, logging interval and resolution must be chosen together.

That applies to anyone studying rainfall erosivity (indices such as EI30 depend on the maximum 30-minute intensity), surface runoff, drainage design or crop response to extreme events. For these uses, the logger should ideally record the time of every pulse, not just a count per interval.

The errors every researcher should know

The WMO instruments guide (WMO-No. 8, precipitation chapter) lists the typical errors of rain gauges and, in particular, those of tipping buckets:

  • Loss during tipping in heavy rain. The bucket takes a finite time to tip; meanwhile water keeps entering the compartment that is already full. The result is underestimated rainfall at high intensities (the effect becomes appreciable above roughly 100 mm/h). Without correction, a tipping bucket tends to underestimate heavy rain and overestimate very light rain.
  • Wind. Wind-field deformation above the gauge orifice typically causes a 2% to 10% loss for liquid rain. It is the main systematic error and depends strongly on the site.
  • Wetting and evaporation. Some water stays on the funnel and bucket walls, and some evaporates — important in hot regions and in light rain.
  • Levelling and friction. A gauge that is not level unbalances the bucket and shifts the calibration.
  • Drizzle and event timing. Because recording is discrete, light drizzle may take a long time to fill a bucket, and the exact start and end time of rain become uncertain.

The good news is that the systematic part of these errors can be corrected. The WMO considers software correction (an intensity-dependent correction curve applied in the logger or in post-processing) the most effective method for mechanical errors. One piece of advice from the same guide applies to any protocol: always keep the raw data, so you can reprocess it if the correction is revised.

Installation: where and how to place the gauge

WMO guidance and ANA's rain gauge station manual agree on the main points:

  1. Distance from obstacles. Trees, buildings and even fences should stand at a distance of at least twice their height above the gauge rim (the WMO prefers four times). ANA adds that this distance should never be less than once the obstacle's height.
  2. Standard height. In ANA's rain gauge network, the gauge rim is installed 1.5 m above the ground so records are comparable. The higher the collector, the stronger the wind and the lower the catch efficiency.
  3. Terrain and rooftops. Avoid hilltops, slopes, hollows and building roofs. Very open, windy sites also reduce catch.
  4. Local interference. Keep the collector away from splashes from puddles and roads, drips from trees and wires and, at stations with a solar panel, from the panel's shading or run-off.
  5. Perfect level. The base must be level; many models include a bubble level and adjustable feet for this.
  6. Access. The gauge must be easy to reach for routine filter cleaning.

If the automatic gauge is installed next to a manual (conventional) gauge, comparing the two is an excellent quality-control tool — the WMO recommends this comparison as good practice to derive local correction factors.

Maintenance and field checks

The minimum routine includes:

  • Cleaning the filter, funnel and bucket, removing leaves, insects, dust, sand and bird droppings. Use a non-aggressive detergent.
  • Checking the level at every visit.
  • Checking calibration. Slowly pour a known volume of water and compare it with the expected number of pulses. On a 400 cm² collector with 0.2 mm resolution, 400 mL equals 10 mm, i.e. 50 tips. Pour slowly, because the inflow rate affects the result. This check does not replace dynamic laboratory calibration (passing water at several flow rates and adjusting the mechanism), but it catches gross deviations.
  • Checking the logger clock and file dates.

The WMO also recommends replacing the tipping mechanism with a freshly calibrated unit once a year. Where birds are common, a ring of bird spikes reduces dirt and interference at the collector rim.

Selection criteria: what to look for on the datasheet

  • Collecting area. 400 cm² is the same area as the conventional gauge used in ANA's network, which makes comparison easier; 200 cm² gives a more compact instrument.
  • Resolution per tip. 0.1 mm, 0.2 mm or 0.5 mm. Finer resolution favours light rain; coarser resolution tolerates higher intensities.
  • Stated accuracy per intensity range and availability of a correction curve.
  • Maximum rainfall rate, relevant for intense convective storms.
  • Output type: dry contact (pulse), 4–20 mA or 0–10 V analog, or SDI-12 digital. Check that your logger has a counter input or an SDI-12 port.
  • Construction: corrosion-resistant materials, protection rating, removable filter and a bird-spike option.
  • A compatible logger that records the time of each pulse, if your study involves intensity.

An example from the catalogue

In the HenSistemas catalogue, the 400 cm² tipping bucket rain gauge (ref. HD2013, by Delta OHM) meets several of these criteria. According to the manufacturer's manual, it is built from corrosion-resistant materials, offers a resolution of 0.1, 0.2 or 0.5 mm per tip (specified when ordering) and an IP64 protection rating. For the 0.2 mm version, stated accuracy is better than 1% up to 30 mm/h and better than 4% up to 100 mm/h; when the intensity-dependent correction curves are applied, the error is typically below ±2% between 0 and 200 mm/h. The maximum rainfall rate is 600 mm/h (0.2 mm version) or 1,000 mm/h (0.5 mm version).

The standard output is a normally closed contact that opens at each tip; optional outputs include 4–20 mA or 0–10 V analog and SDI-12 digital, with a backup battery that keeps the count through short power outages. The removable filter in the funnel makes cleaning easy, and a bird-spike ring can be fitted on request. The manufacturer provides for ground installation or a 500 mm raised mount; other heights, such as the 1.5 m standard used by ANA, should be requested with the quote.

Related products

For the bigger picture of the station, see also the guides How to choose a weather station and Data logger: how to choose the right one.

Checklist before requesting a quote

  1. Does the study need only rainfall totals, or also intensity (erosivity, drainage, extreme events)?
  2. Which resolution suits both the lightest and the heaviest rain at your site?
  3. Does the logger have a counter or SDI-12 input, and does it record the time of each pulse?
  4. Does the site meet the obstacle-distance rule and allow the rim to be installed at 1.5 m?
  5. Who will clean the gauge and run the known-volume check, and how often?
  6. Will there be a manual gauge alongside for comparison?

Answering these questions before the quote avoids the most common frustration in field research: finding out, months later, that the rainfall series cannot support the planned analysis. If you would like help matching your research protocol to the catalogue, talk to the HenSistemas team.