Meteorology · Agriculture · Technical guides
Silicon-cell pyranometer at the weather station: when it is enough, where the errors come from and how to calibrate it against a thermopile
A didactic guide to silicon photodiode pyranometers at research stations: how they work, why calibration holds for clear skies, spectral error under clouds and in reflected light, cosine response, temperature, dirt on the acrylic diffuser and drift, what ISO 9060:2018 says (Class C, not spectrally flat), when the sensor is enough, field cross-calibration against a thermopile with a clear-sky filter and worked example, the FAO-56 Rso envelope, integration to MJ/m²·day, effect on ET₀, dense low-cost networks and Brazilian references.

In many Brazilian research stations, the solar radiation sensor is not a thermopile under a glass dome but a small aluminium cylinder with a white diffuser on top: a silicon-cell pyranometer, also called a photodiode pyranometer. It sits on compact stations at experimental farms, in irrigation-scheduling networks, in extension projects and in the low-cost prototypes built in agricultural engineering labs. It is inexpensive, responds in less than a millisecond, and has no dome to fog up and no desiccant to replace. Precisely because it is so practical, it often enters the methods section of a thesis with a single sentence: "global radiation was measured with a pyranometer".
The question this guide aims to help answer is a different one: for my research, is a silicon pyranometer good enough? The answer depends on understanding where this sensor's errors come from, how they add up (or cancel out) over the day, and what can be done in the field to control them, especially cross-calibration against a thermopile pyranometer. It is written for lecturers, graduate students and technicians in agrometeorology, agricultural engineering, hydrology, ecology and solar energy who are about to buy, inherit or validate this type of sensor.
If you have not read it yet, the guide Pyranometers in weather stations: how to measure solar radiation to research standards covers the thermopile, the ISO 9060:2018 classification, installation and maintenance in general. Here the focus is exclusively on the silicon sensor.
How a silicon-cell pyranometer works
The sensing element is a silicon photodiode: a semiconductor junction that generates an electric current proportional to the number of photons absorbed. That current flows through a resistor (the shunt) and becomes a voltage of a few hundred millivolts in full sun. In front of the photodiode sits a cast acrylic diffuser, which scatters the light so that the sensor responds to radiation coming from the whole hemisphere, not only from above. The assembly is potted solid in resin inside an anodized aluminium body, with no internal air space.
The fundamental difference from the thermopile lies in the physical principle:
- The thermopile absorbs practically all shortwave radiation (about 0.3 to 3 µm) on a black surface and measures the resulting heating. It "weighs" the energy of all wavelengths almost equally.
- The silicon photodiode responds only to part of the solar spectrum and, within it, unevenly. For the sensors discussed in this article, the spectral range stated by the manufacturer is 360 to 1120 nm, defined as the wavelengths at which the response falls to 10% of maximum.
The manual for the Apogee Instruments SP series, one of the most complete references on this type of sensor, states that the range of roughly 350 to 1100 nm contains approximately 80% of total shortwave radiation. The remaining 20%, mainly in the near infrared beyond 1100 nm, is not "seen" by silicon. So how can a sensor that sees only 80% of the spectrum report global radiation in W/m²?
Calibration bridges the gap, but only for one spectrum
The answer is calibration. The manufacturer compares the silicon sensor with reference pyranometers under a known spectrum and sets a factor (in W/m² per mV) that converts the signal into equivalent total radiation. In the Apogee series, for example, the manual describes calibration against the mean of four transfer-standard sensors under metal-halide lamps; those transfer standards are calibrated outdoors under clear skies against ISO-classified reference pyranometers traceable to the World Radiometric Reference (WRR) in Davos. The procedure simulates clear-sky conditions at a solar zenith angle of about 45°.
The practical consequence is the central idea of this guide: a silicon pyranometer is "right" when the spectrum of the light reaching it resembles the spectrum it was calibrated under. When the spectrum changes (clouds, very low sun, light filtered by a canopy, light reflected by soil or vegetation), the calibration factor is no longer exact. This is called spectral error, and it does not appear on any data sheet as a single number.
Where the errors come from
It is worth separating the error sources, because each has a typical signature in the data and a different way of being controlled.
1. Spectral error: cloudy skies, diffuse and reflected light
Under clouds, the radiation reaching the ground is almost entirely diffuse and has a spectral composition different from clear-sky sunlight. The Apogee manual includes a table of estimated spectral errors for its silicon sensors, calculated relative to clear-sky sunlight:
| Radiation source | Estimated spectral error |
|---|---|
| Sun, clear sky | 0.0% |
| Sun, cloudy sky | 9.6% |
| Reflected from grass | 14.6% |
| Reflected from deciduous canopy | 16.0% |
| Reflected from agricultural soil | −12.1% |
| Reflected from water | 6.6% |
| Reflected from snow | 13.7% |
Three lessons come from this table:
- On cloudy days the error can reach the order of 10%, far above the calibration uncertainty. In daily totals for humid regions with many overcast days, this matters.
- A silicon sensor is not suitable for measuring reflected radiation (albedo), because the spectrum reflected by vegetation and soil is very different from sunlight and the error even changes sign depending on the surface. For albedo, use a spectrally flat thermopile, as discussed in the guide Albedo in research.
- Below a canopy the error also grows, because leaves absorb visible light and transmit near infrared. For light under canopies and in greenhouses, the quantity of interest is usually PAR, measured with a quantum sensor, as explained in our guide on photosynthetically active radiation.
The work of King and Myers (1997), at Sandia National Laboratories, is the classic reference on the subject: they showed that, without correction, a photodiode pyranometer's reading can differ from true broadband irradiance by more than 10%, identified the systematic factors that vary over the day (solar spectrum, angle of incidence and temperature) and proposed calibration and correction procedures to compensate for them. In Spain, Raïch, González and Calbó (2007) compared silicon sensors with a high-class thermopile for a year, using 1-minute data, and reached a similar conclusion: angular, spectral and temperature corrections improve agreement, but behaviour under clouds remains the weak point.
2. Cosine response and low sun
An ideal pyranometer responds to the cosine of the zenith angle: the same direct irradiance, arriving at a slant, should produce a signal proportional to cos(θz). The acrylic diffuser is designed for this but is not perfect. For the series discussed here, the manufacturer states an error of ±5% at a 75° zenith angle; the Apogee manual details roughly ±2% at 45° and ±5% at 75°, based on measurements made during outdoor radiometer calibrations at NREL (the US National Renewable Energy Laboratory).
Note that when the sun is low the spectrum also changes (more air mass, redder light), so the directional error measured in the field already includes part of the spectral error. In practice:
- The relative error is large early in the morning and late in the afternoon, but irradiance at those times is small and its weight in the daily total is modest.
- In southern Brazil's winter, the noon sun is much lower. In Porto Alegre (about 30° S), at the June solstice, the noon zenith angle exceeds 50°; still far from 75°, but the sensor spends more time in the range where the error grows.
- For studies using 1- to 10-minute data, such as irradiance ramps or photovoltaic modelling, cosine error must be included explicitly in the uncertainty budget.
3. Temperature
Photodiode sensitivity varies with temperature. For the series discussed here, the manufacturer states a coefficient of 0.04 ± 0.04% per °C. That looks small, and usually is: a 25 °C difference between the calibration temperature and a sensor heated by the noon sun in the Cerrado amounts to roughly 1%. Still, it is a systematic error, always in the same direction on hot days, and it should be mentioned. Those who need more accuracy can measure the sensor body temperature and correct for it, as Raïch and colleagues did.
One point in favour of silicon: the photodiode does not have the thermal offset of thermopiles (slightly negative values at night and signal dips when the dome cools). At night, a silicon sensor reads practically zero.
4. Dirt, dew and the acrylic diffuser
The dome-shaped diffuser and rounded body help dew and rain run off, which is why the manufacturer speaks of "self-cleaning". Even so, the Apogee manual notes that moisture or debris on the diffuser is a common cause of low readings: dust during dry spells, salt from evaporating sprinkler water or sea spray, bird droppings. The recommendations are simple:
- remove dust and organic deposits with water or window cleaner and a soft cloth or cotton swab;
- dissolve salt deposits with vinegar;
- never use abrasive materials or cleaners, which scratch the acrylic and permanently change its transmission and directional response.
Where dew or frost is frequent, there are versions with an internal heater that keeps the body a few degrees above air temperature and reduces water on the diffuser. Under centre pivots, watch the sensor's position relative to the water jet: salt deposits from irrigation water are a classic cause of slow drift. The guide on PV module soiling discusses how to quantify soiling losses; the same reasoning applies to the diffuser.
5. Drift and ageing
The manufacturer states long-term drift of less than 2% per year, and the Apogee manual recommends recalibration every two years, allowing longer intervals depending on the study's tolerance. In a five-year series with no checks, this can amount to several percent of spurious trend, enough to contaminate studies of radiation or evapotranspiration trends. That is why the field verification discussed below is not optional.
Summary: a simple uncertainty budget
For a typical agrometeorological station with a clean, level sensor, a qualitative budget looks like this:
| Source | Order of magnitude | Behaviour |
|---|---|---|
| Factory calibration | < 3% to ±5% (depending on source) | systematic, constant |
| Spectral (clouds) | up to ~10% on overcast days | depends on sky type |
| Cosine | ±2% at 45°; ±5% at 75° | depends on time of day and season |
| Temperature | ~1% on hot days | systematic, seasonal |
| Dirt | 0 to several % | grows between cleanings |
| Drift | < 2% per year | grows over time |
The good news is that the systematic errors (calibration, drift, part of the temperature effect) can be measured and corrected by cross-calibration. Sky-dependent errors (spectral and part of cosine) can be reduced but not eliminated, and that is where the choice between silicon and thermopile is made.
What ISO 9060:2018 says about silicon sensors
ISO 9060:2018 classifies pyranometers into classes A, B and C, which replaced the former names "secondary standard", "first class" and "second class". The standard is explicit on two points that matter here:
- Classification is based solely on measurement specifications, not on manufacturing technology. A photodiode sensor can therefore, in principle, be classified.
- Besides the classes, the standard created two additional qualifiers: "fast response", for sensors with a 95% response time below 0.5 s, and "spectrally flat", for sensors whose spectral selectivity (the percentage deviation of spectral responsivity from its mean between 0.35 and 1.5 µm) is below 3%. The standard itself notes that, for photodiodes, responsivity may be zero over part of that range, and spectral selectivity may reach 100% or more.
The result is that a good silicon pyranometer can be fast-response Class C, but never spectrally flat. That is how Apogee classifies its SP series sensors, and NovaLynx's data sheet for the equivalent series also states Class C under ISO 9060:2018. The Apogee manual adds that silicon specifications compare favourably with the WMO moderate and good quality categories, but that, because of their limited spectral sensitivity, they do not meet the spectral specification required for WMO certification.
One sentence from the standard is worth quoting in class: the class is an accuracy ranking for well-maintained instruments, and a lower-class sensor can be more appropriate in some cases. The example given by ISO itself is the measurement of highly variable irradiance (such as over-irradiance events caused by cloud edges), where fast response can outweigh a lower class. In Brazil, the Fotovoltaica/UFSC group studied precisely the performance of different radiometers during over-irradiance events in Florianópolis (Martins, Mantelli and Rüther, 2022).
When a silicon pyranometer is enough (and when it is not)
With this picture, we can propose a decision rule. A silicon sensor is usually enough when:
- the variable of interest is incoming global radiation on a horizontal or tilted surface under open sky;
- the main use is irrigation scheduling, daily ET₀, crop growth models or teaching, where a daily uncertainty of a few percent is acceptable;
- you need many measurement points (dense network, transects, terrain gradients, multi-plot experiments) and the budget cannot cover a thermopile at each;
- the application calls for fast response: cloud variability over seconds, ramp tracking at PV plants;
- the sensor will be field-calibrated against a reference thermopile and checked periodically.
A silicon sensor is not enough, and a thermopile should be chosen, when:
- radiation is the main variable in a study of energy balance, turbulent fluxes or radiation climatology;
- you will measure reflected radiation, albedo or below-canopy radiation;
- the series will be used for long-term trend studies or compared with reference networks;
- you need to separate diffuse and direct rigorously, as discussed in the guide Diffuse radiation, direct radiation and sunshine duration; with a shadow ring the sensor sees only the sky, whose spectrum differs from the sun's, and silicon's spectral error comes back;
- the paper will go to a journal that requires a spectrally flat classification or documented traceability to a Class A or B instrument.
Many groups adopt the most efficient middle ground: one reference thermopile at the main station and several silicon sensors calibrated against it across the network or the plots.
Field cross-calibration against a thermopile
Cross-calibration means installing the silicon sensor side by side with a freshly calibrated thermopile pyranometer (preferably Class A or B) and computing a correction factor. The idea is the same as in ISO 9847, which covers calibration of field pyranometers by comparison with a reference pyranometer. Below is a practical procedure.
Set-up
- Install both sensors in the same plane, a few decimetres apart, both level, with a clear horizon and no mutual shading. The connector should point south in the Southern Hemisphere, as recommended for the thermopile.
- Connect both to the same data logger, with the same scan rate (for example 1 s or 10 s) and 1- to 10-minute averages. The logger needs adequate resolution: for a self-powered sensor at 0.2 mV per W/m², a resolution of 0.2 mV equals 1 W/m². The guide on the programmable data logger covers input range, differential mode and the 60 Hz filter.
- Clean both sensors at the start and log every cleaning.
- On the silicon sensor, use the manufacturer's nominal factor and also store the raw signal in mV so you can recompute later.
Duration and season
Manufacturers recommend clear skies and high sun; the Oklahoma Mesonet, for example, used 1 to 2 weeks of side-by-side comparison with a thermopile on high-sun days before moving to a lamp-based calibration bench. In Brazil, the study by Sánchez-Benítez and colleagues (2022), published in the journal IRRIGA, evaluated 16 low-cost photodiode pyranometers over 414 days and estimated that 32 days of comparison were needed to calibrate with 99.7% confidence. In practice, three to six weeks covering clear and cloudy days is a good compromise. In central Brazil, the dry season (May to September) offers many clear days; on the coast and in the Amazon you may need to wait longer.
Clear-sky filter
To estimate the calibration factor without mixing in cloud spectral error, use only clear-sky, high-sun intervals. A simple set of criteria, which you should describe in your methods:
- zenith angle below 60° (or 70° in southern Brazil's winter);
- reference irradiance above, say, 300 W/m²;
- low variability within the interval (standard deviation of 1-s readings small relative to the mean), which removes passing clouds;
- for daily totals, a ratio of measured to clear-sky radiation (Rs/Rso, see below) close to 1, for example above 0.9.
Daily ratio or regression?
There are two common ways to compute the factor:
- Ratio of sums: k = Σ(reference) ÷ Σ(silicon), summing only the intervals that pass the filter. It is robust and easy to reproduce.
- Daily ratio: compute k for each day (using daily totals) and take the median. This lets you see whether k changes with season, temperature or cleaning.
Avoid linear regression with a free intercept: the silicon sensor has a true zero at night, and a fitted intercept usually just absorbs morning and afternoon cosine errors. If you want regression, force it through the origin.
Worked example
The following example is illustrative, with plausible numbers, to show the calculation. A station in Piracicaba (São Paulo state), at 22.7° S and 546 m elevation, compared in July a self-powered silicon sensor (nominal factor 5.0 W/m² per mV, i.e. 0.2 mV per W/m²) with a freshly calibrated Class B thermopile.
First, the expected clear-sky radiation. Using FAO-56, for 15 July at 22.7° S, daily extraterrestrial radiation is Ra ≈ 23.6 MJ/m²·day. Clear-sky radiation is Rso = (0.75 + 2×10⁻⁵ × z) × Ra = (0.75 + 0.011) × 23.6 ≈ 18.0 MJ/m²·day.
Five selected clear days (Rs/Rso > 0.9 on the thermopile):
| Day | Thermopile (MJ/m²) | Silicon, nominal factor (MJ/m²) | Thermopile/silicon ratio |
|---|---|---|---|
| 1 | 17.2 | 17.8 | 0.966 |
| 2 | 17.4 | 18.0 | 0.967 |
| 3 | 16.9 | 17.5 | 0.966 |
| 4 | 17.1 | 17.7 | 0.966 |
| 5 | 17.3 | 17.9 | 0.966 |
The median ratio is k = 0.966: with the nominal factor, the silicon sensor overestimated by about 3.4% under clear skies. The new factor is 5.0 × 0.966 = 4.83 W/m² per mV, and this value should be recorded with the date, the sensor serial number and the identity of the reference.
After correction, also compare the cloudy days, without using them in the fit. If, on those days, the ratios range from, say, 0.95 to 1.04, that spread is the spectral and cosine error that calibration does not remove, and it is what belongs in the uncertainty discussion of your work.
Checking without a reference: the clear-sky envelope
Not every station has a thermopile nearby. For those, the best routine test is to compare the series with clear-sky radiation:
- For daily totals, use the FAO-56 Rso. Allen (1996), in the paper that became the reference for assessing the integrity of weather data for ET₀, proposed plotting measured daily radiation together with the Rso curve over the year: the clearest days should "touch" the curve. If the upper envelope of the data stays systematically above or below Rso for several weeks, there is a calibration, levelling or dirt problem.
- Near solar noon, use a clear-sky calculator. The Apogee manual suggests that if, over several clear days, measurements near noon consistently differ from calculated values by more than 6%, the sensor should be cleaned and re-levelled; if the difference persists, it should be sent for recalibration.
Two cautions: thin high clouds and cloud edges can raise irradiance above the clear-sky value for a few minutes (spikes, not a constant offset), and smoke from fires, common between August and October across much of Brazil, lowers actual clear-sky radiation. Smoky days should not be used to judge calibration.
The guide on the integrated weather station and quality control shows how to organise these tests alongside comparison with INMET stations.
From irradiance to daily totals: integrating to MJ/m²·day
The sensor delivers instantaneous irradiance (W/m²). For ET₀, crop models and radiation balance, what matters is accumulated energy. Correct integration follows three rules:
- Integrate from short averages. Compute 1- to 10-minute means from readings every few seconds and multiply by the interval length. With 10-minute means: daily total (MJ/m²) = Σ(10-min mean in W/m²) × 600 s ÷ 1,000,000.
- Use the right conversions. Daily mean in W/m² × 0.0864 gives MJ/m²·day. One hour at 1 W/m² equals 3.6 kJ/m². INMET's automatic stations publish hourly global radiation in kJ/m²: an hour averaging 650 W/m² corresponds to 2,340 kJ/m².
- Do not "zero" the night blindly. For silicon, night values should be practically zero; positive night readings point to noise, artificial lighting or a wiring problem and deserve investigation, not just a filter.
How much does an Rs error weigh on ET₀?
In the FAO-56 Penman-Monteith method, radiation enters the net radiation term: the shortwave part is Rns = 0.77 × Rs, and the longwave part depends on the Rs/Rso ratio. An illustrative example for a summer day in Piracicaba (Tmax 31 °C, Tmin 20 °C, actual vapour pressure 2.2 kPa, 2-m wind speed 1.8 m/s, Rs = 22.0 MJ/m²·day) gives ET₀ ≈ 5.15 mm/day. With Rs 5% higher (23.1 MJ/m²), ET₀ rises to about 5.31 mm/day; with Rs 5% lower (20.9 MJ/m²), it drops to about 4.98 mm/day. In other words, a 5% error in radiation becomes an error of about 3% in ET₀, around 0.16 mm/day in this example. Over a 120-day crop cycle, a systematic bias of that size adds up to almost 20 mm of water depth.
That is why cross-calibration pays off: it removes the systematic bias, which accumulates, leaving mainly the random cloud error, which partly cancels out over weeks. The IRRIGA study reached a similar conclusion: with the low-cost sensors calibrated, deviations in Penman-Monteith ET₀ were below 0.22 mm/day in 95% of observations, about 3.6 times smaller than those obtained when radiation was estimated with the locally calibrated Hargreaves-Samani equation. The guide on reference evapotranspiration shows the full calculation.
Dense low-cost networks
Silicon's greatest advantage is enabling spatial density. A few real examples help put this in scale:
- The Oklahoma Mesonet (USA), one of the best-known state networks, used silicon photodiode pyranometers at more than a hundred stations, with individual calibration coefficients applied to the data and periodic calibration against a reference (McPherson et al., 2007).
- In Brazil, Sánchez-Benítez and colleagues (2022) built photodiode pyranometers at an approximate total cost of US$ 27 and achieved an uncertainty of ±0.04 MJ/m²·day in global radiation after calibration, considered sufficient for ET₀ at automatic stations in open fields or in protected environments.
- The UFSC solar energy group (Mantelli Neto et al., 2024) compared Class A and B thermopile sensors and semiconductor sensors at a precision solarimetric station under clear, cloudy and mixed skies, and found much lower uncertainty and variance in the Class A thermopiles; the differences shrank progressively as data were aggregated to 10, 20 and 60 minutes and to daily totals.
The lesson from all three is the same: silicon works in networks when there is a calibration and verification strategy. In practice this means:
- Calibrate all sensors side by side against the same thermopile before installation (ideally at the same time, on a sensor "rack").
- Store the individual factor for each serial number.
- Keep one or two "transfer" sensors that rotate through the network for cross-checks.
- Apply the clear-sky envelope to all stations monthly.
- Recalibrate or replace sensors on a rotating basis every one or two years.
Installation and maintenance specific to silicon
The general pyranometer installation rules (clear horizon, no mast shading, level) apply in full. Some particularities of silicon sensors:
- Levelling plate. The small body has no bubble level; the manufacturer offers a levelling plate and a bracket with level as accessories. A sensor tilted 2° towards the north measures a different irradiance, not the horizontal one.
- Nylon screw. The Apogee manual recommends using the supplied nylon screw to insulate the aluminium thread from the base and prevent galvanic corrosion.
- Cable orientation. To minimise azimuth error (typically below 1%), point the cable south in the Southern Hemisphere.
- Cable and wiring. Self-powered models output millivolts. The Apogee manual states that with high-impedance inputs (1 MΩ or more), splicing up to 100 m of cable has a negligible effect on calibration; use shielded twisted-pair cable and connect the shield to the logger ground.
- Output matched to the logger. The series is offered as a self-powered 0 to 400 mV version and as amplified 0 to 2.5 V, 0 to 5 V and 4 to 20 mA versions, which require power. Amplified outputs are more immune to noise on long cables; the self-powered version draws no power, which helps on small solar-powered stations.
- Cleaning routine. Include the diffuser in the same visit in which the rain gauge is cleaned, with a note in the field log.
Catalogue example: silicon-cell pyranometer series
In the HenSistemas catalogue, the silicon-cell pyranometers product page (ref. 280-SP) describes a sensor of this type: cast acrylic diffuser, photodiode and signal-conditioning circuitry potted in an anodized aluminium body, dome-shaped head for dew and rain runoff, optional in-line connector 30 cm from the head and 5 m of shielded twisted-pair cable (with extensions in multiples of 5 m). According to the product page, the sensor has a spectral range of 360 to 1120 nm, cosine response of ±5% at a 75° zenith angle, non-linearity below 1% up to 2000 W/m², drift below 2% per year, and operates from −40 °C to +70 °C, 0 to 100% humidity, and can even be submerged to 30 m.
The text and specifications on the product page match those of NovaLynx's (USA) silicon-cell pyranometer series, currently catalogued by the manufacturer as 240-SP, whose models in turn correspond to Apogee Instruments' SP series. Two points deserve attention when specifying:
- The product page states a calibration uncertainty of ±5%, the same value as NovaLynx's product web page; the manufacturer's latest data sheet and the Apogee manual state less than 3% at 1000 W/m². For design and methods purposes, use the value on the certificate that comes with the sensor.
- The manufacturer's data sheet adds information the product page lacks: fast-response Class C under ISO 9060:2018, response time below 1 ms, temperature coefficient of 0.04 ± 0.04% per °C and the output versions (self-powered 0 to 400 mV, at 0.2 mV per W/m²; 0 to 2.5 V; 0 to 5 V; 4 to 20 mA).
When quoting, the HenSistemas team confirms the output version, cable length and availability of a heated model.
Related products
- LightScout silicon pyranometer (ref. 3670I): 300 to 1100 nm silicon sensor that works with WatchDog stations and the LightScout handheld reader.
- Photodiode solar radiation sensor (ref. SSR1D): photodiode alternative with 0 to 3 V output and an IP67 body; the product page notes that its calibration applies to natural light.
- Compact weather station with ET₀ calculation (ref. WatchDog 2900ET, 3350WD2): compact station that measures solar radiation and computes ET₀, typical of irrigation scheduling.
- Delta OHM Class C thermopile pyranometer (ref. LPPYRA03): spectrally flat, same accuracy class as silicon but without spectral error; a good option where clouds are frequent.
- Kipp & Zonen pyranometers: a line of thermopiles in several classes, with analogue and digital outputs, useful as a station reference.
- EKO Class A pyranometer (ref. MS-80): spectrally flat and fast response; a natural candidate as the reference for calibrating a network of silicon sensors.
- Class B pyranometer with shadow ring (ref. LPPYRA12): for measuring diffuse radiation, a task in which silicon has a larger spectral error.
- Housing with acquisition system for weather stations (ref. HD32.35): data logger in a stainless-steel enclosure for building the reference station and the side-by-side comparison.
See also the guide Data logger: how to choose the right one.
Checklist before choosing (or publishing with) a silicon pyranometer
- Is the variable incoming global radiation under open sky? (If it is reflected, below-canopy or diffuse, prefer a thermopile.)
- Is a daily uncertainty of a few percent acceptable for the scientific question?
- Is a reference thermopile (Class A or B) available for cross-calibration, at the station or at a partner institution?
- Is the calibration factor used recorded, with serial number, date and reference?
- Do the methods describe the clear-sky filter and the cross-calibration period?
- Has the series been compared with the FAO-56 Rso and with nearby INMET stations?
- Does the sensor output (mV, V, mA) match the logger input and resolution?
- Is there a diffuser cleaning routine, without abrasives, with dates logged?
- Are the raw data (mV) stored alongside the converted values?
- Does the paper state that the sensor is a photodiode, Class C, not spectrally flat, and discuss the error on cloudy days?
References
- International Organization for Standardization. ISO 9060:2018 — Solar energy — Specification and classification of instruments for measuring hemispherical solar and direct solar radiation. Geneva: ISO, 2018.
- International Organization for Standardization. ISO 9847 — Solar energy — Calibration of field pyranometers by comparison to a reference pyranometer.
- World Meteorological Organization. Guide to Instruments and Methods of Observation (WMO-No. 8), Volume I, Chapter 7 (Measurement of radiation).
- Apogee Instruments. Pyranometer — Models SP-110 and SP-230: owner's manual (July 2025 revision) and SP-110-SS specifications page.
- NovaLynx Corporation. 240-SP Series Silicon Cell Pyranometers (data sheet DS 20221201) and product page.
- King, D. L.; Myers, D. R. Silicon-photodiode pyranometers: operational characteristics, historical experiences, and new calibration procedures. In: 26th IEEE Photovoltaic Specialists Conference, 1997. DOI: 10.1109/PVSC.1997.654323.
- Raïch, A.; González, J. A.; Calbó, J. Effects of solar height, cloudiness and temperature on silicon pyranometer measurements. Tethys, v. 4, p. 11–18, 2007. DOI: 10.3369/tethys.2007.4.02.
- McPherson, R. A. et al. Statewide monitoring of the mesoscale environment: a technical update on the Oklahoma Mesonet. Journal of Atmospheric and Oceanic Technology, v. 24, n. 3, 2007.
- Allen, R. G. Assessing integrity of weather data for reference evapotranspiration estimation. Journal of Irrigation and Drainage Engineering, v. 122, n. 2, p. 97–106, 1996.
- Allen, R. G.; Pereira, L. S.; Raes, D.; Smith, M. Crop evapotranspiration — Guidelines for computing crop water requirements. FAO Irrigation and Drainage Paper 56. Rome: FAO, 1998.
- Sánchez-Benítez, J.; Fraga Junior, L. S.; Amaral, A. M.; Vellame, L. M. Avaliação de protótipos de sensores de radiação solar de baixo custo para estimativa da evapotranspiração potencial. IRRIGA, v. 27, n. 3, p. 607–623, 2022. DOI: 10.15809/irriga.2022v27n3p607-623.
- Mantelli Neto, S. L.; Santos, D. C.; Queiroz, I. M.; Rüther, R. Intercomparação entre piranômetros para estabelecer um padrão de referência local. In: Congresso Brasileiro de Energia Solar (CBENS), 2024. DOI: 10.59627/cbens.2024.2542.
- Martins, G. L.; Mantelli, S. L.; Rüther, R. Evaluating the performance of radiometers for solar overirradiance events. Solar Energy, v. 231, p. 47–56, 2022. DOI: 10.1016/j.solener.2021.11.050.
- HenSistemas product page: silicon-cell pyranometers.
Instruments for this application

Spectrum Technologies3670I
LightScout Silicon Pyranometer

Spectrum Technologies3350WD2
WatchDog 2900ET Weather Station

DeltaOhm - GHM GroupLPPYRA03
LP PYRA 03 Second Class Pyranometers to ISO 9060

Kipp & Zonenkipp&zonen
Kipp & Zonen Pyranometer for Solar Irradiance Measurement

DeltaOhm - GHM GroupLPPYRA12
LPPYRA12 Series – Spectrally Flat Class B Pyranometers with Shadow Ring

DeltaOhm - GHM GroupHD32.35