Meteorology · Agriculture · Technical guides

Leaf wetness at the weather station: how to measure leaf wetness duration, install the sensor and estimate it from relative humidity for disease warnings

A didactic guide to measuring leaf wetness at the weather station: what LWD is and why it is non-standard, the wetness requirement of Asian soybean rust, the resistance-grid sensor and its wet threshold, painting and heat treatment, the 30 cm / 30° reference position above turfgrass (Piracicaba studies), estimation from RH ≥ 90% with local calibration, an illustrative example, logging interval, quality control and Brazilian references.

By HenSistemas · · 17 min read

Compact weather station with rain gauge, shield and solar panel mounted on a mast in the middle of a maize field under a stormy sky

Among the variables an agricultural weather station can record, few have as much influence on disease management as leaf wetness. Fungi and bacteria that attack leaves and fruit need free water on the plant surface to germinate, penetrate the tissue and sporulate. That is why leaf wetness duration (LWD) is an input to most plant disease warning systems and to many epidemiological models used in master's and doctoral research.

This guide is for professors, graduate students and technicians in plant pathology, agrometeorology and crop science who want to add leaf wetness to their station. The goal is to explain what LWD really is, why it is a "difficult" variable, how the sensor works, where to install it according to research carried out in Brazil, when it makes sense to estimate LWD from relative humidity, and how to build a data series that will stand up to examiners and reviewers. Air temperature and humidity measurement, which runs through this whole discussion, is covered in air temperature and humidity at the weather station.

What LWD is and why it is not an "ordinary" variable

LWD is the time during which free water — from dew, rain, fog or irrigation — is present on the aerial surfaces of plants. Gleason et al. (2008), in a review published in Scientia Agricola, sum up the problem: LWD is a non-standard variable, because it is a property of surfaces as much as of the atmosphere; there is no widely accepted calibration standard for the sensors; and the vast majority of automated weather stations in the world do not have this sensor.

Three practical consequences for researchers:

  1. The number depends on the method. Two stations a few metres apart, with different sensors or installed differently, can record LWD values that differ by an hour or more on the same night.
  2. The leaf is not the sensor. The sensor imitates a leaf, but it has its own size, colour, tilt and heat capacity. What it measures is an approximation of crop wetness.
  3. The protocol must be written down. Height, angle, orientation, painting, the "wet" threshold and the logging interval are part of the method, just as the radiation shield type is part of a temperature measurement.

Order of magnitude: how much wetness matters

A Brazilian example shows why hours make a difference. For Asian soybean rust, the controlled-environment studies of Marchetti et al. (1976) and Melching et al. (1989) found a minimum of six hours of leaf wetness for infection to occur, at temperatures between 22 and 24 °C; at the extremes, infection occurred from 9 °C to 28.5 °C, but with wetness periods longer than 12 hours, according to the summary by Godoy and Del Ponte (2006), researchers at Embrapa Soja and Iowa State University.

The same text makes a point every field researcher should keep in mind: rain wets leaves too, and its effect cannot be reproduced in growth-chamber trials. In Brazil, Del Ponte et al. (2006) found a strong association between final rust severity and the number of rainy days and total rainfall in the 30 days after disease establishment, across 35 monitored epidemics. In other words, at a station built for disease warning, rain, temperature, relative humidity and leaf wetness must be on the same data logger and the same clock.

Note the scale: the difference between a "risk" night and a "no-risk" night can be one or two hours of wetness. That is the same order of magnitude as the installation errors we will see below. This is why measurement quality matters so much.

How a resistance-grid sensor works

The most common sensor at agricultural stations is a circuit board with interlaced metal traces, like two combs fitted together without touching. When the board is dry, the electrical resistance between the traces is very high. When dew or rain droplets bridge the traces, resistance drops. The logger measures this resistance and applies a threshold: below it, the surface is considered wet.

The leaf wetness sensor compatible with WatchDog stations, for example, uses a grid with gold-plated traces and converts resistance into a scale from 0 (dry) to 15 (wet), in whole numbers; the manufacturer's manual considers any value above 6 as "wet". Other sensors output resistance, a voltage or a count of wet minutes. In every case the same lesson applies: the threshold defines LWD, and it must be stated in the methodology.

There are also cylindrical sensors, originally developed for onions. Santos et al. (2008) evaluated this type under tropical conditions in Brazil, comparing it with flat-plate sensors. After setting a specific resistance threshold for each sensor, the mean coefficient of variation among cylinders fell to 9.7%, and deployment angle had no systematic effect under local conditions, with high correlation (R² > 0.91) between cylinders and plates.

Painting and heat treatment: why a "bare" sensor gets it wrong

Very small dew droplets may not be enough to close the circuit between the traces of an unpainted plate. The result is a sensor that "wakes up" late and underestimates wetness onset. The solution, tested by Sentelhas, Monteiro and Gillespie (2004) in the International Journal of Biometeorology, is to paint the sensor. The paint spreads the droplets and brings the plate's optical properties closer to those of a leaf; the clearest effect was a reduction in variation among sensors. In the work of Santos et al. (2008), all sensors received white latex paint and heat treatment before the trials.

In practice:

  • Follow the manufacturer's recommendation for your sensor. Some models leave the factory ready to use; on others, painting changes the threshold and requires a new check.
  • Treat every sensor in the network the same way. Painting one and not another introduces a systematic difference.
  • Test before going to the field. Spray distilled water, observe the response time and note the dry and wet values of each unit.

Where and how to install: the reference condition

The question "at what height and at what angle?" has an experimental answer, and much of it was built in Piracicaba, São Paulo State. Sentelhas et al. (2004), in Agricultural and Forest Meteorology, compared flat-plate sensors at several heights and angles with visual observations of dew onset and dry-off in Elora (Canada), Ames (USA) and Piracicaba. The main results:

  • Sensors 30 cm above turfgrass, tilted between 15° and 45°, had the smallest errors relative to visual observations; the 30 cm, 30° position was adopted as the reference.
  • Sensors at 190 cm measured a shorter average LWD: 54 minutes less in Piracicaba and 97 minutes less in Elora.
  • There was no significant difference between 30 cm and 70 cm.
  • Horizontal or near-horizontal sensors (0° and 15°) measured longer LWD: 56 minutes more in Piracicaba, because water pools and drains slowly.
  • The sensor 30 cm above turfgrass estimated LWD well at the top of very different crops; measurements inside the canopy varied much more.

In Sentelhas's habilitation thesis (ESALQ/USP, 2004), with experiments also in Jundiaí (SP) and crops such as cotton, coffee, maize, muskmelon, apple, tomato and grape, the conclusion is the same: painting reduces variation among sensors, position above turfgrass has a significant effect, and reference LWD agrees well with LWD at the top of the plants, but does not reliably predict LWD inside the canopy.

Simple installation rules follow:

  • For a reference station (comparing sites, feeding models, building a long series): plate 30 cm above mown turfgrass, tilted at 30°, out of reach of sprinklers.
  • For a crop-specific question (wetness in the lower third of a coffee canopy, for example): install sensors in the canopy, at the position relevant to the disease, and keep the reference sensor as well. The Spectrum sensor manual suggests the same logic: under the canopy to capture mainly the effect of rain, near the top to capture both rain and dew.
  • Orientation: North American guides (for example, the University of Florida's) say to face the tilted surface north, the side that receives less direct sun in the Northern Hemisphere. The logic is to face the sensor toward the pole; in Brazil, that means facing south. Record the orientation you adopt.
  • Protect cables from mowers and animals, and keep the logger within reach of the sensor cable without improvised splices.

Measure or estimate? The relative humidity method

Because few stations have a wetness sensor, researchers developed ways to estimate LWD from weather data. The simplest is to count the hours with relative humidity ≥ 90%. The physical rationale is that the leaf surface cools below air temperature at night through radiative loss and reaches the dew point before the air at 1.5–2 m reaches 100%.

Sentelhas et al. (2008) tested this method and two variants at four sites, including Piracicaba:

  • The constant RH ≥ 90% threshold was generally the best of the empirical models tested, with a fraction of correct estimates between 0.87 and 0.92 (0.90 in Piracicaba).
  • In Piracicaba the 90% model underestimated LWD; in Florence it overestimated. The ideal threshold changes with climate.
  • With locally calibrated thresholds, the mean absolute error was between 1.23 and 1.89 h, comparable to published physical models. In Piracicaba, the calibrated threshold was exactly 90%.
  • The extended RH method (which considers the rate of change of RH) overestimated LWD at all sites and was considered unsuitable.

Physical models, based on the surface energy balance (such as the Penman-Monteith approach applied to a "virtual sensor"), depend on wind and radiation and are more portable between sites. In Sentelhas's thesis (2004), four estimation methods had mean absolute errors between 1.27 and 2 h in cotton, and the Penman-Monteith-based model estimated LWD with good accuracy without local calibration. That requires wind and radiation at the station; the underlying physics is in reference evapotranspiration ET0 with FAO-56.

The teaching recommendation: measure LWD with a sensor and also record RH at the same point. With one or two seasons of paired data, you can calibrate the RH threshold for your site and gain an estimator that works even at neighbouring stations without the sensor.

Illustrative example: one night, three numbers

Imagine a summer night at a soybean field trial, logging every 15 minutes (hypothetical values, to teach the reasoning):

  • The reference sensor (30 cm, 30°) crosses the threshold at 21:15 and returns to dry at 08:45: measured LWD = 11.5 h.
  • RH in the shield, at 1.5 m, stays ≥ 90% from 22:00 to 08:00: estimated LWD = 10 h.
  • Mean temperature during the wet period is 22.5 °C, and there was no rain.

What can we conclude? First, the RH estimator started late and ended early, as Sentelhas et al. (2008) observed in Piracicaba for the 90% threshold. Second, by both methods the night comfortably exceeded the six-hour minimum reported for Asian soybean rust in the 22–24 °C range. Third, if the risk model you use was developed with a flat-plate sensor at 30 cm, feeding it RH-based estimates requires adjusting the threshold or acknowledging the method difference. This is the kind of detail that separates a useful series from one that was merely recorded.

Logging interval and the "wetness day"

  • Interval: use 15 minutes or less. With hourly logging, each dry–wet transition carries up to one hour of uncertainty — the same order of magnitude as the signal.
  • Wet-hour criterion: decide and document it. Does an hour count as wet if any reading is wet? If most are? The results change.
  • Daily window: dew begins at night and ends in the morning. Summing LWD from midnight to midnight splits one event across two days. One solution is a 24-hour window that starts at noon; whatever you choose, it must be in the text.
  • Events, not just totals: keep the start and end of each wet period, the mean temperature during it and whether there was rain. Many infection models ask precisely for "wet hours at a given temperature".
  • A single clock in UTC for all loggers, as at any research station.

What the station needs

A station built for leaf wetness and disease warning needs, at minimum:

  • Temperature and relative humidity in a radiation shield — the basis for the RH method and for temperature during wetness.
  • A rain gauge to separate rain wetness from dew wetness. The resolution and field calibration of a tipping-bucket gauge are covered in tipping-bucket rain gauge in research.
  • An input for the leaf wetness sensor and a short logging interval.
  • Autonomous power and telemetry, because a warning is only valuable if it arrives in time. We discuss the options in weather station telemetry.

The WatchDog 3000 wireless rain weather station brings this set together in a single body: it measures rain, temperature and relative humidity and accepts a leaf wetness sensor, a soil moisture sensor or a PAR light sensor. According to the product sheet, it sends data over cellular to the SpecConnect cloud (which requires an annual subscription per station), is configured through the app via Bluetooth, stores 30,000 intervals in internal memory (about 312 days at a 15-minute interval, overwriting the oldest records when memory is full), comes with a 3.5 W solar panel and a 6 V / 4.5 Ah SLA battery with a minimum autonomy of 14 days without sun, operates from −30 °C to 55 °C and mounts on a 1.25-inch mast.

According to the manufacturer's documentation, the integrated rain gauge is a tipping bucket with 0.25 mm per tip (the manual states that 84 mL of water should register 2.5 mm, or 10 tips, in the calibration test), and the cloud platform offers optional disease and insect models. One point to check: the website's product sheet lists one external sensor port (2.5 mm jack connector, analog), while the manufacturer's specification sheet for the 3220 series describes two additional ports. If your project needs leaf wetness and soil moisture on the same station, confirm the configuration with the technical team before planning the experiment. Also confirm cellular coverage at the installation site.

Data quality control

  • Sensor "stuck" wet: wet values on a sunny afternoon point to dirt, spider webs, leaves, pesticide residue or irrigation-water salts on the grid. The Spectrum sensor manual recommends periodic cleaning with distilled water.
  • False wet at high RH: painted sensors may read wet on very humid nights without visible dew. Compare with RH and, from time to time, with visual observation at dawn.
  • Consistency with rain: every recorded rain event should produce wetness; long wetness without rain and with low RH is suspect.
  • Irrigation: flag sprinkler irrigation times; they produce wetness that is not meteorological.
  • Replicates: two sensors side by side at the reference position let you quantify unit-to-unit variation and detect failures.
  • Raw and derived data: archive the raw sensor value, the threshold used and the computed LWD. If the threshold changes, you can recompute without losing the series.

How to choose

Related products

Checklist before using LWD in your thesis

  1. Is the sensor in the reference position (30 cm above turfgrass, 30°), or is the canopy position justified by the research question?
  2. Are painting, treatment and the "wet" threshold described and identical across all sensors?
  3. Was the orientation of the tilted face recorded?
  4. Is the logging interval 15 minutes or less, with a single clock in UTC?
  5. Were temperature, relative humidity and rain measured on the same logger?
  6. Are the wet-hour criterion and the daily window defined in the method?
  7. Were there periodic cleaning, replicate sensors and visual checks at dawn?
  8. If LWD was estimated from RH, was the threshold calibrated locally against the sensor?

If the answer is "yes" to all of them, your leaf wetness stops being a dashboard number and becomes scientific data.

References

  • Gleason, M. L.; Duttweiler, K. B.; Batzer, J. C.; Taylor, S. E.; Sentelhas, P. C.; Monteiro, J. E. B. A.; Gillespie, T. J. Obtaining weather data for input to crop disease-warning systems: leaf wetness duration as a case study. Scientia Agricola, v. 65, special issue, p. 76–87, 2008. DOI: 10.1590/S0103-90162008000700013.
  • Sentelhas, P. C.; Gillespie, T. J.; Gleason, M. L.; Monteiro, J. E. B. A.; Helland, S. T. Operational exposure of leaf wetness sensors. Agricultural and Forest Meteorology, v. 126, p. 59–72, 2004. DOI: 10.1016/j.agrformet.2004.05.009.
  • Sentelhas, P. C.; Monteiro, J. E. B. A.; Gillespie, T. J. Electronic leaf wetness duration sensor: why it should be painted. International Journal of Biometeorology, v. 48, p. 202–205, 2004. DOI: 10.1007/s00484-004-0200-z.
  • Sentelhas, P. C. et al. Suitability of relative humidity as an estimator of leaf wetness duration. Agricultural and Forest Meteorology, v. 148, p. 392–400, 2008. DOI: 10.1016/j.agrformet.2007.09.011.
  • Santos, E. A.; Sentelhas, P. C.; Gillespie, T. J.; Lulu, J. Performance of cylindrical leaf wetness duration sensors in a tropical climate condition. Scientia Agricola, v. 65, special issue, p. 1–9, 2008. DOI: 10.1590/S0103-90162008000700003.
  • Sentelhas, P. C. Duração do período de molhamento foliar: aspectos operacionais da sua medida, variabilidade espacial em diferentes culturas e sua estimativa a partir do modelo de Penman-Monteith. Habilitation thesis (Livre-Docência) — ESALQ/USP, Piracicaba, 2004.
  • Rowlandson, T.; Gleason, M.; Sentelhas, P.; Gillespie, T.; Thomas, C.; Hornbuckle, B. Reconsidering leaf wetness duration determination for plant disease management. Plant Disease, v. 99, n. 3, p. 310–319, 2015. DOI: 10.1094/PDIS-05-14-0529-FE.
  • Melching, J. S.; Dowler, W. M.; Koogle, D. L.; Royer, M. H. Effects of duration, frequency, and temperature of leaf wetness periods on soybean rust. Plant Disease, v. 73, p. 117–122, 1989. DOI: 10.1094/PD-73-0117.
  • Godoy, C. V.; Del Ponte, E. M. Epidemias de ferrugem asiática e meio ambiente. Visão Agrícola, n. 5, p. 100–101, ESALQ/USP, 2006.
  • Del Ponte, E. M.; Godoy, C. V.; Li, X.; Yang, X. B. Predicting severity of Asian soybean rust epidemics with empirical rainfall models. Phytopathology, v. 96, p. 797–803, 2006. DOI: 10.1094/PHYTO-96-0797.
  • University of Florida, IFAS Extension. How to avoid common problems with leaf wetness sensor installation and maintenance. Publication AE538.
  • Hensistemas product sheet: WatchDog 3000 wireless rain weather station.

Instruments for this application