Meteorology · Agriculture · Water · Technical guides

Reference evapotranspiration at the weather station: how to measure the inputs and compute ET₀ with FAO-56 for research

A teaching guide to reference evapotranspiration (ET₀) with the FAO-56 Penman-Monteith method: ET₀ vs ETc vs actual ET, the sensors a station needs, a step-by-step worked example, sensitivity to radiation, humidity and wind errors, site installation, hourly calculation, gap filling, Kc and quality control.

By HenSistemas · · 17 min read

Wireless weather station with anemometer, solar panel and radiation shield for evapotranspiration calculation

Evapotranspiration is probably the most widely used derived product of an agricultural weather station. It feeds irrigation scheduling, catchment water balances, crop growth models, land-use change studies and comparisons between seasons. Even so, theses and reports often present ET as a ready-made number exported from software, without saying where the inputs came from, at what height they were measured or which equation was applied. For research, that is not enough: evapotranspiration is not measured by the station — it is calculated from four or five measured quantities, and each one carries its own error into the result.

This guide explains, in a teaching style, what reference evapotranspiration (ET₀) is, how the FAO-56 Penman-Monteith method calculates it, which sensors the station needs and how to install them, how much each measurement error weighs in the result, how to move from ET₀ to crop evapotranspiration (ETc), and which quality-control checks reviewers expect. The focus is the researcher at Brazilian public universities — USP, the federal universities and research institutes — who needs reliable, reproducible and well-documented ET.

Three concepts that must not be confused

Before any equation, it is worth separating three quantities that are often mixed up in applied literature:

  • Reference evapotranspiration (ET₀): the rate of water loss from a hypothetical grass surface, 0.12 m tall, with a fixed surface resistance of 70 s m⁻¹ and an albedo of 0.23, fully covering the ground and not short of water. It is a climatic quantity: it depends only on the weather and the site, not on the crop or the soil.
  • Crop evapotranspiration (ETc): the water loss of a specific crop, healthy, well managed and not water-limited, under the same weather. It is usually obtained by multiplying ET₀ by a crop coefficient (Kc).
  • Actual or adjusted evapotranspiration (ETa or ETc adj): what really happens in the field, with water stress, salinity, disease, stand gaps or imperfect management. It is less than or equal to ETc and requires direct measurement (lysimeter, energy balance, eddy covariance) or soil water balance modelling.

The weather station alone provides ET₀. Moving to ETc and ETa is the researcher's job. Making this explicit in the methods section avoids one of the most frequent criticisms from committees and reviewers: calling "crop evapotranspiration" what is really ET₀ multiplied by a table Kc.

Why FAO-56 became the standard

Until the 1990s dozens of ET₀ methods coexisted — Thornthwaite, Blaney-Criddle, Hargreaves, Priestley-Taylor, modified Penman, Class A pan — with results that could differ by 20% to 40% for the same day. FAO Irrigation and Drainage Paper No. 56 (Allen, Pereira, Raes and Smith, 1998) standardized the calculation with a specific form of the Penman-Monteith equation and fixed parameters for the reference grass. In 2005 ASCE published the American standardized version, whose "short reference" form is mathematically equivalent to FAO-56.

The main advantage is physical: the equation combines a radiation term (the energy available to evaporate water) with an aerodynamic term (the ability of the air to remove vapour), instead of relying on empirical correlations calibrated in another climate. That is why it transfers well between Brazil's Semi-arid region, the Cerrado and the South, provided the input data are good.

The FAO-56 daily equation (equation 6 of the paper) is:

ET₀ = [0.408 Δ (Rn − G) + γ (900 / (T + 273)) u₂ (es − ea)] / [Δ + γ (1 + 0.34 u₂)]

where:

  • ET₀ — reference evapotranspiration (mm day⁻¹);
  • Rn — net radiation at the surface (MJ m⁻² day⁻¹);
  • G — soil heat flux (MJ m⁻² day⁻¹), which can be taken as zero at the daily scale;
  • T — mean air temperature at 2 m (°C);
  • u₂ — wind speed at 2 m (m s⁻¹);
  • es − ea — vapour pressure deficit (kPa);
  • Δ — slope of the saturation vapour pressure curve (kPa °C⁻¹);
  • γ — psychrometric constant (kPa °C⁻¹), proportional to atmospheric pressure.

What the station needs to measure

Reading the equation backwards, the sensor list follows naturally. A station for FAO-56 ET₀ needs at least:

  1. Air temperature — daily maximum and minimum (or hourly means for the hourly calculation). It enters Δ, the aerodynamic term, saturation vapour pressure and long-wave radiation.
  2. Relative humidity (or dew-point temperature) — to compute actual vapour pressure (ea) and therefore the vapour pressure deficit.
  3. Global solar radiation (Rs) — measured with a pyranometer. From it, FAO-56 estimates net radiation (Rn) with standardized procedures, so a net radiometer is not mandatory.
  4. Wind speed — ideally at 2 m, or converted to 2 m.
  5. Atmospheric pressure — optional: FAO-56 allows it to be estimated from elevation with small error for ET₀ purposes.

Rainfall does not enter the ET₀ equation, but it is essential for the water balance: without a rain gauge at the same site, ET₀ cannot be turned into an irrigation depth or a soil water storage estimate. Wind direction is not used in the calculation either, but it helps diagnose obstructions and fetch effects.

Each of these quantities has been covered in detail in earlier guides: solar radiation and pyranometers, air temperature and humidity with a radiation shield, wind measurement, atmospheric pressure and tipping bucket rain gauges. Here the focus is on how they combine.

Step by step: the daily calculation

FAO-56 describes a sequence of calculations that every researcher should be able to reproduce in a spreadsheet or an R or Python script. These are the points where mistakes are most common:

1. Saturation vapour pressure (es). Compute e°(T) = 0.6108 exp(17.27 T / (T + 237.3)) for the maximum and for the minimum, and then average. Plugging the daily mean temperature straight into the formula underestimates es because the function is non-linear — a classic error in improvised spreadsheets.

2. Actual vapour pressure (ea). The preferred method uses dew-point temperature; failing that, combine maximum RH with minimum temperature and minimum RH with maximum temperature: ea = [e°(Tmin) × RHmax/100 + e°(Tmax) × RHmin/100] / 2. Using mean RH alone is accepted but is the least accurate option.

3. Extraterrestrial radiation (Ra) and clear-sky radiation (Rso). Ra depends only on latitude and day of year; Rso = (0.75 + 2 × 10⁻⁵ z) Ra, where z is elevation in metres. The ratio Rs/Rso indicates the day's cloudiness.

4. Net radiation (Rn). Net short-wave radiation is Rns = (1 − 0.23) Rs. Net long-wave radiation (Rnl) is estimated with the Stefan-Boltzmann law, using maximum and minimum temperatures in kelvin, corrected for air humidity (via ea) and cloudiness (via Rs/Rso). Then Rn = Rns − Rnl.

5. Wind at 2 m. If the anemometer is at another height, convert with the FAO-56 logarithmic profile: u₂ = u_z × 4.87 / ln(67.8 z − 5.42). At 10 m the factor is 0.748; at 3 m, 0.921.

6. Psychrometric constant. γ = 0.665 × 10⁻³ P, with P in kPa — measured by the barometer or estimated from elevation.

A worked example

Consider a mid-October day at an inland São Paulo State site, at 22.7° S and 546 m elevation, with a maximum temperature of 31 °C, a minimum of 17 °C, maximum RH of 90%, minimum RH of 40%, mean wind of 2.0 m s⁻¹ at 2 m and global solar radiation of 22 MJ m⁻² day⁻¹. Following the procedure:

  • pressure estimated from elevation: 95.0 kPa; γ ≈ 0.063 kPa °C⁻¹;
  • es ≈ 3.22 kPa; ea ≈ 1.77 kPa; vapour pressure deficit ≈ 1.45 kPa;
  • Ra ≈ 38.1 MJ m⁻² day⁻¹; Rso ≈ 29.0 MJ m⁻² day⁻¹;
  • Rns ≈ 16.9; Rnl ≈ 4.0; Rn ≈ 13.0 MJ m⁻² day⁻¹;
  • ET₀ ≈ 5.3 mm day⁻¹, of which about 3.3 mm comes from the radiation term and 1.9 mm from the aerodynamic term.

The example illustrates something important for Brazil: for most of the year and most of the country, solar radiation accounts for the largest share of ET₀, with the vapour pressure deficit second. In dry, windy periods — the Cerrado winter, the Semi-arid region, dry cold fronts in the South — the aerodynamic term grows and wind gains weight.

How much each measurement error weighs

Using the same example gives a practical feel for sensitivity (the numbers change with climate and season, but the order of magnitude is useful for planning an uncertainty budget):

  • Solar radiation 5% too high → ET₀ about 2.7% higher. Since field silicon pyranometers typically have an uncertainty of around ±5%, and higher-class thermopile pyranometers reach ±2–3% on daily totals, the choice of radiation sensor is one of the decisions that most affect ET₀.
  • RH 3 percentage points too high → ET₀ about 1.8% lower. RH sensors that drift in very humid conditions (dewy early mornings) are a silent source of bias.
  • Temperature 0.3 °C too high → small effect, under 1%. But a poor radiation shield can cause 1–2 °C errors at midday, and then the effect shows.
  • Wind measured at 10 m and used as if at 2 m → ET₀ about 7% higher in this example. Forgetting the height conversion is a surprisingly common systematic error.
  • Station on a dry site without irrigated grass (maximum 2 °C higher and minimum RH 8 points lower than over a reference surface) → ET₀ about 8% higher. This is the "aridity" effect described in Annex 6 of FAO-56.

The lesson is that, for ET₀, the radiation sensor and site conditions matter more than temperature, and the anemometer height must be in the metadata.

Where and how to install a station for ET₀

ET₀ is defined for a well-watered grass surface. The further the station's surroundings depart from that, the further the calculated ET₀ departs from the definition. Practical recommendations:

  1. A low, grassed and preferably irrigated surface, with a fetch of a few tens of metres to, ideally, 100 m in the prevailing wind direction. Stations over bare soil, gravel, roofs or next to car parks overestimate ET₀.
  2. Temperature and humidity between 1.5 and 2.0 m, in a naturally ventilated or aspirated radiation shield.
  3. Wind at 2 m (or a documented height with the conversion applied), away from obstacles: the rule of thumb is a distance of at least ten times the height of trees and buildings.
  4. Pyranometer level and never shaded by the mast, antenna or solar panel at any hour of the day, all year round — in the Southern Hemisphere the north side of the mast is usually the safest.
  5. A rain gauge at the same site, with its rim level and away from the mast.
  6. Photos of all four quadrants, coordinates, elevation and the height of each sensor in the station log.

On university experimental farms it is common to install the station in the middle of the trial itself, surrounded by soybean or maize. That is useful for characterizing the experiment's microclimate, but the resulting ET₀ is not strictly "reference". If the station serves both purposes, say so in the methods.

Logging interval: daily or hourly?

FAO-56 also provides an hourly equation (equation 53), with 37/(T + 273) instead of 900/(T + 273) and with G estimated as 0.1 Rn during the day and 0.5 Rn at night. Summing hourly values tends to represent days with abrupt changes — a passing front, partial cloud, wind shifting in the afternoon — better than using daily means.

In practice, for research, we recommend:

  • logging at 15 minutes or less and keeping the raw data;
  • calculating both hourly and daily ET₀ and checking their consistency;
  • documenting which scale was used in the analyses and why.

When data are missing

Every long series has gaps. FAO-56 provides procedures to fill them without abandoning Penman-Monteith:

  • Missing radiation: estimate Rs from the temperature range (Rs = kRs √(Tmax − Tmin) Ra, with kRs ≈ 0.16 inland and 0.19 for coastal regions) — acceptable to fill a few days, never months.
  • Missing humidity: assume the dew-point temperature is close to the minimum temperature, with an adjustment in dry climates.
  • Missing wind: use the local mean, or 2 m s⁻¹ as a generic value, bearing in mind that this smooths variability.

The best-known alternative when only temperature is available is the Hargreaves-Samani equation: ET₀ = 0.0023 (Tmean + 17.8) (Tmax − Tmin)^0.5 Ra, with Ra expressed in mm day⁻¹. In the example above it would give about 5.6 mm day⁻¹, roughly 6% above Penman-Monteith. In several Brazilian regions Hargreaves needs local calibration to avoid overestimating ET₀ in humid climates. For regional-scale work, the daily gridded meteorological dataset for Brazil (Xavier, King and Scanlon) is also a frequent reference, but it does not replace local measurement in field trials.

From ET₀ to crop evapotranspiration

With ET₀ in hand, crop evapotranspiration without water limitation is ETc = Kc × ET₀. FAO-56 tabulates Kc values by stage (initial, mid and late). Some mid-season values, for the reference sub-humid climate, are: grain maize, 1.20; soybean, 1.15; sugarcane, 1.25. In the example, a maize crop at full development would be using about 1.20 × 5.3 ≈ 6.3 mm day⁻¹.

Three methodological points:

  • Climatic adjustment of Kc: table values assume a minimum RH of 45% and wind of 2 m s⁻¹; FAO-56 provides a correction for other conditions.
  • Dual Kc (Kcb + Ke): separating transpiration (basal coefficient) from soil evaporation is more appropriate with frequent irrigation, partial ground cover or no-till with straw.
  • Validation: when the project requires measured ETc, the standards are weighing lysimeters, the Bowen ratio or eddy covariance. The weather station provides the reference; direct measurement provides confirmation.

In a simplified water balance, the irrigation depth for a period is ETc minus effective rainfall, taking into account the soil's available water capacity — which links ET₀ to soil moisture monitoring.

Quality control reviewers expect

FAO-56 and the ASCE standardization include a list of checks worth building into routine:

  • Clear-sky envelope: on clear days, Rs should touch the Rso curve. Values systematically below suggest a dirty dome, poor levelling or shading; above, a calibration error.
  • Minimum temperature vs dew point: at reference sites, dew-point temperature stays close to the minimum. A large, persistent difference suggests a dry site or a faulty RH sensor.
  • Maximum RH close to 100% on humid nights: if it never exceeds 90–92% in a humid climate, the sensor is probably drifting.
  • Wind: days with constant or zero speed point to a seized bearing or a communication fault.
  • Comparison with the nearest INMET automatic station for temperature, RH and radiation, allowing for differences in elevation and surface.
  • Metadata: sensor models and serial numbers, heights, calibration dates, logging interval, the equation used (FAO-56 daily or hourly, ASCE), and gap-filling procedures.

A good practice is to publish the raw series and the calculation script as supplementary material. This makes the work reproducible and removes doubts about software "black boxes".

What to look for when choosing a station for ET₀

When comparing equipment, go beyond the brochure line "calculates evapotranspiration":

  • Which variables are measured and which are estimated? Radiation measured with a pyranometer is essential for a good-quality Penman-Monteith.
  • Type and uncertainty of the radiation sensor: silicon (fast response, lower cost, uncertainty of around ±5%) or thermopile (ISO 9060 class, lower uncertainty).
  • Sensor mounting height and whether wind can be placed at 2 m.
  • Access to raw data at short intervals, not just the finished ET.
  • Power autonomy and communications suited to the site: solar panel, cellular, radio or satellite.
  • Expandability for rainfall, soil moisture or leaf wetness, depending on the project.

An example from the catalogue

In the HenSistemas catalogue, the WatchDog wireless evapotranspiration station from Spectrum Technologies (model 3250 on the product sheet) is a good illustration of an integrated field instrument for ET₀. It brings together in a single unit the sensors FAO-56 calls for: air temperature (range −40 to 125 °C, accuracy ±0.3 °C between −40 and 90 °C), relative humidity (10% to 100%, ±2% at 25 °C), wind speed (±3 km/h or ±5%) and direction (±3°), solar radiation from a silicon pyranometer (0 to 1500 W m⁻², ±5%) and rainfall from a self-emptying tipping bucket (0.254 mm resolution, ±2% up to 5 cm/h).

The internal logger stores 30,000 intervals — about 312 days at 15 minutes —, power comes from a 3.5 W solar panel with a 6 V, 4.5 Ah battery (at least 14 days without sun), and communication can be cellular, USB, Bluetooth or RS232. Data go to the SpecConnect cloud, where ET is calculated and followed in reports; for research, this guide's recommendation still applies: export the raw 15-minute series and recompute ET₀ with the procedure documented in your methods. Two points to note from the sheet and the manual: it mounts on a 1.25-inch mast, and the height should be planned so that wind and temperature are close to 2 m; and, in the ET configuration, the external sensor port is already used by the pyranometer, so soil moisture or leaf wetness call for a second instrument. For the uncertainty budget, the ±5% of the silicon pyranometer is consistent with irrigation management and most agronomic trials; energy balance or climate trend studies may justify a higher-class thermopile pyranometer.

Related products

For the broader design context, see also How to choose a weather station and Data logger: how to choose the right one.

Checklist before requesting a quote

  1. Is the goal reference ET₀, the trial's microclimate, irrigation management or all three? That defines the site and the surface around the station.
  2. Does the station measure solar radiation with a pyranometer, and what is that sensor's uncertainty?
  3. Will temperature and humidity be between 1.5 and 2.0 m, in a suitable radiation shield?
  4. Will wind be at 2 m, or will the height be documented for conversion?
  5. Is there a rain gauge at the same site for the water balance?
  6. Can raw data at 15-minute intervals or shorter be exported?
  7. Will the methods state the equation (FAO-56 daily or hourly, ASCE), gap filling and the crop coefficients used?
  8. Is there a quality-control plan (clear-sky envelope, dew point vs minimum, comparison with INMET)?

With these answers on paper, evapotranspiration stops being a software number and becomes a research result — traceable, reproducible and defensible before any committee.

Instruments for this application