Atmospheric pressure at the weather station: how to measure, reduce to sea level and use it in research
A teaching guide to atmospheric pressure at the research station: station pressure versus MSLP, the effect of elevation (e.g. São Paulo at ~760 m), the FAO-56 role (psychrometric constant γ), WMO-aligned installation, SDI-12 integration, calibration, quality control and a checklist.

Atmospheric pressure rarely features on the poster of a research weather station. Temperature, rainfall and wind take centre stage. Even so, pressure enters almost every calculation the researcher makes afterwards: FAO-56 reference evapotranspiration, reduction to mean sea-level pressure (MSLP), air density used in energy-balance work and sensor corrections, field barometric altitude, and comparison with INMET stations. Measuring pressure poorly is therefore not a minor instrumentation detail: it is an error that propagates through derived products.
This guide explains, in a teaching tone, what the station barometer actually records, why sea-level reduction is not optional when sites must be compared, how pressure enters the FAO-56 psychrometric constant, what the World Meteorological Organization (WMO-No. 8) recommends for siting and calibration, and how to integrate a digital SDI-12 transmitter on the station bus. The audience is researchers at Brazilian public universities — USP, federal universities and institutes — who need a reliable, traceable and well-documented series.
What the sensor measures: station pressure, not "the weather"
The station barometer measures atmospheric pressure at the instrument, also called station pressure or site pressure. In SI units the result is in hectopascals (hPa), numerically equal to millibars (mbar). Typical values near sea level sit close to 1013 hPa; in São Paulo, at about 760 m elevation, station pressure usually oscillates around 920–930 hPa, depending on the air mass.
That already clarifies the first common mistake: comparing raw pressure from a station on the São Paulo plateau with one on the coast is comparing two quantities of different natures. Elevation dominates the signal. Operational networks and weather bulletins therefore almost always publish pressure reduced to mean sea level (MSLP; in aviation, the closely related QNH concept). MSLP is calculated from station pressure, the barometer altitude and, in fuller formulae, air temperature and humidity in the column.
In short:
- Station pressure (P): what the sensor measures and what the data logger should store raw.
- MSLP: what is published so that weather systems can be compared across sites at different elevations.
- Barometric altitude: another reduction, used in the field and in navigation, that converts pressure into height under a standard atmosphere.
For research the practical rule is clear: always record station pressure, with the sensor altitude well documented. Sea-level reduction (or any other) can be recomputed later; the inverse conversion from an already-reduced value without metadata almost never works.
Why elevation matters so much
Pressure falls with height in a roughly exponential way. A useful rule of thumb near the surface is that pressure drops about 1 hPa every 8–9 m of elevation under near-standard conditions. At 760 m, as over much of the city of São Paulo, the difference from sea level already exceeds 80 hPa. In Brasília (~1,100 m) or Campos do Jordão (~1,600 m) the gap is larger still.
Practical consequences for the project:
- Altitude error becomes MSLP error. If the barometer altitude is wrong by 10 m, the sea-level reduction is biased by about 1 hPa — the same order as many research-grade sensors.
- Instrument height on the mast matters. WMO guidance calls for documenting barometer height above ground and, where possible, the geodetic elevation of the site (preferably referred to a known datum). Moving the sensor from a 1.5 m enclosure to the top of a 10 m mast without updating metadata corrupts the reduced series.
- Comparisons with INMET require the same quantity. Brazil's National Institute of Meteorology automatic stations publish station pressure and, in derived products, MSLP. Before validating your series against the neighbouring station, check that you are comparing station pressure with station pressure — and that the elevations are coherent.
A numerical example helps. Suppose station pressure is 925.0 hPa at 760 m, with air temperature 20 °C. Using a simplified hypsometric reduction (locally isothermal atmosphere), MSLP is close to 1,013 hPa. If the elevation in the station log is 15 m too high, the computed MSLP rises by about 1.7 hPa — a systematic shift across the whole series that can be mistaken for "sensor drift".
Sea-level reduction in field language
There are several reduction formulae. WMO describes operational procedures; in research the important point is to choose one formula, document it and apply it consistently. A classic hypsometric form for an isothermal layer between the site and sea level is:
P₀ = P × exp(g × z / (R_d × T_v))
where P₀ is MSLP, P station pressure, g gravitational acceleration, z barometer altitude, R_d the specific gas constant for dry air and T_v the mean virtual temperature of the column. In field practice T_v is usually approximated from air temperature and humidity measured at the station — which is why the same site needs a well-sited relative humidity and temperature sensor with SDI-12 output inside a radiation shield.
Points the researcher must close in the methods:
- Reference elevation: consumer GPS often has several metres of vertical error; prefer a topographic survey, a geodetic benchmark or, at least, averaged differential GPS / RTK when available.
- Temperature used in the reduction: column mean, station temperature, or a standard constant? Record the choice.
- Units: work in hPa (or Pa) and metres; avoid mixing mmHg and inches of mercury without an explicit conversion (1 hPa = 0.750062 mmHg).
If the study only needs a local water balance or ET₀ at the site itself, MSLP may not be required — station pressure enters the equations directly. If the goal is synoptic work, regional validation or a publication comparing sites, a well-done reduction is part of the data.
The role of pressure in FAO-56
The FAO-56 bulletin (Allen et al.) uses atmospheric pressure at two central points in the reference evapotranspiration (ET₀) calculation:
- Atmospheric pressure estimated from elevation when no local measurement is available: P = 101.3 × ((293 − 0.0065 × z) / 293)^5.26, with P in kPa and z in metres (equation 7). That approximation assumes a standard atmosphere and is excellent for filling gaps, but it does not replace a good barometer when the site has a particular microclimate, when fronts and pressure systems are studied, or when a smaller uncertainty is wanted.
- Psychrometric constant γ, which appears in the Penman-Monteith equation: γ = 0.665 × 10⁻³ × P, with γ in kPa °C⁻¹ and P in kPa (equation 8). In other words, γ is directly proportional to pressure.
Orders of magnitude help set expectations. At sea level (P ≈ 101.3 kPa), γ ≈ 0.067 kPa °C⁻¹. In São Paulo at 760 m (P ≈ 92.6 kPa from the elevation formula), γ falls to about 0.062 kPa °C⁻¹. The difference does not explode ET₀ on its own, but it enters the Penman-Monteith denominator together with the aerodynamic term and the vapour-pressure deficit. At elevated sites, casually using a sea-level γ is an avoidable systematic error.
Pressure (via air density) also appears in sonic-anemometer corrections, in some energy-balance algorithms and in vapour-unit conversions. That is why research stations that already measure temperature, humidity and radiation — see the guide Air temperature and humidity at the weather station — gain thermodynamic coherence by adding the barometer on the same bus.
Sensor types and what to look for on the datasheet
Automatic-station barometers today are almost all electronic. The most common principles:
- Piezo-resistive: a diaphragm with a Wheatstone bridge whose resistance changes with pressure-induced deformation. This is the standard for most field digital transmitters: compact, low power and easy to integrate.
- Capacitive: pressure changes the spacing of capacitor plates. Good stability; common in laboratory instruments and some high-precision sensors.
- Resonant / quartz: frequency of a pressure-sensitive crystal. Used in references and in national-network reference stations.
When reading the datasheet, go beyond the headline number:
- Accuracy over the typical meteorological range (for example 800–1,100 hPa), not only at full scale.
- Resolution — useful for short-term trends, but not to be confused with accuracy.
- Long-term stability / drift, in hPa per year.
- Temperature compensation: the pressure reading depends on element temperature; serious sensors calibrate at more than one thermal point.
- Operating temperature range compatible with the site climate (frost in southern Brazil, 45 °C in the semi-arid region).
- Output: SDI-12, Modbus, 4–20 mA, 0–10 V. On solar stations with several sensors, a digital bus reduces noise and makes swaps easier.
- Ingress protection (IP) of the housing and presence of a pressure compensation element (the breather that equalises internal pressure without letting water in).
WMO discusses mercury, aneroid and electronic barometers in the instruments guide. For automatic research stations in Brazil, the dominant path is digital electronic, with traceable factory calibration and a plan for periodic verification.
Where and how to install
The barometer does not need a radiation shield in the same way a thermometer does, but it does need a thermally stable, ventilated environment without artificial pressure. Practical recommendations in the spirit of WMO guidance:
- Avoid air-conditioning ducts, exhaust fans, climate-chamber doors and pressurised rooms. A few pascals of offset already show up in the series.
- Prefer a ventilated enclosure or a dedicated box on the mast, with the compensation element free — no tape, no silicone blocking the breather.
- Protect from direct rain and strong sun on the housing, not because pressure "wants shade", but because fast thermal gradients increase the residual error of temperature compensation.
- Document height above ground and site elevation. Photograph the installation from the four quadrants.
- Keep clear of vibration and impact sources (pumps, generators, gate stops). Piezo-resistive diaphragms dislike continuous mechanical shock.
- Cable with slack and strain relief, especially on masts that sway in the wind.
On compact stations it is common to mount the transmitter on the mast itself or inside the data-logger cabinet, provided the cabinet has adequate breathing. If the sensor sits inside a cabinet that is too sealed, internal pressure can lag or distort real variations — the instrument's own compensation element only solves that if it is in contact with the atmosphere.
SDI-12 integration with the data logger
SDI-12 (Serial Digital Interface at 1200 baud) is the three-wire serial protocol (power, ground and data) designed for environmental sensors. Each sensor has an address; the logger issues a command, the sensor replies in physical units and returns to low-power sleep. For the barometer that means:
- a reading already in hPa (or the configured unit), with no current/voltage conversion along the cable;
- the ability to share the bus with temperature/RH, radiation, soil moisture and others;
- sensor swaps with minimal reprogramming, if the new device speaks the same SDI-12 dialect.
In the catalogue, loggers such as the HD33MT.4 for weather stations, the GPRS HS14GS-SDI12 and the DataSnap Solar SDI-12 exemplify the family of data loggers that talk natively to SDI-12 probes. The guide Data logger: how to choose the right one goes deeper into channels, telemetry and power.
Recording interval: for MSLP and synoptic tracking, one hour is classic; for fronts, gusts and correlation with wind, 1–10 minutes make sense. The important point is that the barometer interval talks to the rest of the station — temperature, humidity and wind on the same time stamp.
Calibration, drift and quality control
Every serious transmitter leaves the factory with individual calibration. For typical field piezo-resistive sensors, calibration at two temperatures and two pressures covers the thermal coupling of the element. That does not remove the need for verification over the life of the project:
- Periodic checks against a calibrated reference barometer (a laboratory in Brazil's RBC / Inmetro network, or a traceable travelling instrument).
- Cross-checks with the nearest INMET automatic station, comparing station pressure (not MSLP) and accounting for the elevation difference.
- Series quality control: steps after maintenance, values outside the physical range of the site (for example 1,050 hPa at 800 m), frozen readings (stuck sensor), high-frequency noise incompatible with atmospheric inertia, and odd correlation with housing temperature (a symptom of poor thermal compensation or a blocked breather).
- Metadata: serial number, factory calibration date, adopted elevation, reduction formula (if any), and any applied adjustment. Keep the raw data.
Slow drift of tenths of an hPa per year is expected in many electronics; the problem is undocumented drift. Plan verification as a routine project item, not as a reaction to a rejected paper.
An example from the catalogue
In the HenSistemas catalogue, the air pressure transmitter with SDI-12 output (model SP1A) is a clear example of a sensor designed for a research station. According to the datasheet, the element is piezo-resistive, with ±1.5 mbar (±1.5 hPa) accuracy, SDI-12 output compatible with market loggers, and an IP65 high-quality ABS housing (polycarbonate optional). A pressure compensation element in the enclosure equalises internal pressure while keeping the unit waterproof — a critical point for mast or wall mounting.
Each unit is calibrated individually at two temperatures and two pressures before leaving the manufacturer; the sensing element can be recalibrated with specialist equipment if needed. Mounting options include wall, mast or mast boom. For the uncertainty budget of an ET₀ experiment or regional validation, ±1.5 hPa is coherent with use on automatic research stations; absolute-reference studies or long-term climate trends may require a tighter metrological class and more frequent calibration.
Related products
- Relative humidity and temperature sensor with SDI-12 output: needed for sea-level reduction with virtual temperature and for the full FAO-56 calculation (eₐ, VPD, ET₀).
- HD33MT.4 data logger for weather station: master SDI-12 port and telemetry to concentrate pressure, temperature, humidity and other sensors.
- GPRS HS14GS-SDI12 data logger: cellular telemetry for remote sites with SDI-12 probes.
- DataSnap Solar SDI-12 with solar panel: autonomous option for field sites without mains power.
- SSR1D solar radiation sensor: completes the station energy set in the same SDI-12 ecosystem.
- TDR-315H soil moisture sensor with SDI-12 interface: closes the site water balance together with rainfall, ET₀ and pressure.
For the broader project context, see also How to choose a weather station, Air temperature and humidity at the weather station and Data logger: how to choose the right one.
Checklist before you request a quote
- Will pressure be used for local ET₀, for MSLP/synoptic work, for air density, or for all three? That defines accuracy, recording interval and whether sea-level reduction enters the data flow.
- Is the barometer elevation known to better than ~5–10 m? Who signs off the metadata?
- Is the installation free of air conditioning, exhausts and pressurised rooms?
- Does the data logger speak SDI-12 (or the chosen output) and have power compatible with a solar station?
- Is there a temperature and humidity sensor at the same site for reduction and for FAO-56?
- Is there a plan to check against a reference and to compare with the neighbouring INMET station (station pressure × station pressure)?
- Does the station log record serial number, factory calibration, height, elevation and MSLP formula, if applicable?
With those answers on paper, choosing the transmitter stops being one more line in the budget and becomes part of the experimental design — which is exactly where atmospheric pressure should have been from the start.