Meteorology · Water · Technical guides
Underwater light in research: how to measure PAR below the surface with a submersible logger, calculate the attenuation coefficient and euphotic zone and combine it with the weather station
A didactic guide to measuring photosynthetically active radiation underwater in lakes, reservoirs, ponds and coastal waters: why the Secchi depth is not enough, the Beer-Lambert law, the attenuation coefficient Kd and euphotic zone, limits of the 1.7 factor (Padial and Thomaz), the immersion effect and when it cancels out, logger calibration and intercalibration, mounting, biofouling, step-by-step calculation with a worked example, combining with weather-station PAR, rain and wind, and applications in Brazilian research.

In almost every project in limnology, aquaculture, aquatic plant ecology or coastal science, the light that reaches below the water surface is a central variable. It decides how deep phytoplankton can photosynthesise, where submerged macrophytes can establish, how much oxygen a fish pond produces during the day and whether a seagrass meadow or a bed of calcareous algae receives enough light to grow. Even so, in many reports underwater light appears only as a Secchi disk reading taken on the sampling day.
This guide explains, in classroom language, how to measure photosynthetically active radiation (PAR) underwater with submersible loggers, how to turn those readings into the vertical attenuation coefficient (Kd) and the euphotic zone depth, why a sensor calibrated in air reads low in water (the immersion effect) and how to combine the series with the weather station to separate real changes in the water from a simple cloudy day. It is written for lecturers, graduate students and technicians in limnology, oceanography, environmental engineering, aquaculture and ecology who are planning a campaign or validating data already collected.
If the concepts of PAR and PPFD are not yet clear, start with the guide Photosynthetically active radiation (PAR) in research: what PPFD is, how to measure it and when to use a quantum meter. Here we build on it and go below the surface.
Why measure light underwater, and not just the Secchi depth
The Secchi disk is cheap, quick and has decades of historical records in Brazil. But it measures visual transparency: the depth at which a white disk disappears from the human eye. Photosynthesis, on the other hand, depends on the number of photons between 400 and 700 nm reaching each depth over the whole day. The two are related, but they are not the same quantity, and the relationship between them changes with water type.
A submersible PAR logger adds three things the Secchi disk cannot give:
- A physical quantity with units. PPFD in µmol m⁻² s⁻¹ and, integrated over time, daily light in mol m⁻² day⁻¹ (the same DLI used in plant physiology).
- A continuous series. A weekly Secchi reading misses the turbidity pulse after a heavy storm, the resuspension caused by a windy cold front or the algal bloom that builds up in three days.
- Observer-free measurement. It does not depend on visual acuity, time of day, surface glare or who took the reading.
This does not retire the disk. Combining both is best practice: the Secchi depth keeps your data comparable with the literature and with older series; the logger shows the dynamics and lets you calibrate the Secchi–Kd relationship for your own water body.
What happens to light when it enters the water
Reflection at the surface
Part of the light reaching the surface is reflected before entering. With a high sun and calm water the loss is a few percent (at normal incidence the transmittance of the air–water surface is around 0.98); with a low sun, waves and a lot of diffuse light, the reflected fraction increases. That is why the light just below the surface (called E(0⁻)) is always somewhat lower than the value measured by the weather station in air (E(0⁺)).
Absorption and scattering: the Beer–Lambert law
Below the surface, downwelling irradiance decreases approximately exponentially with depth z:
E(z) = E(0⁻) · e^(−Kd · z)
The vertical attenuation coefficient for downwelling irradiance (Kd, in m⁻¹) summarises the effect of four components that absorb or scatter light:
- Water itself, which strongly absorbs red light.
- Coloured dissolved organic matter (CDOM, the "humic substances"), which absorbs blue light and gives water a tea colour; it dominates the Amazon's blackwater rivers and peat-bog lagoons.
- Phytoplankton, which absorbs through its pigments, mainly in the blue and red.
- Suspended inorganic particles (silt and clay), which scatter light and lengthen the photons' path; they dominate whitewater rivers, reservoirs after rain and wind-mixed shallow lakes.
Because each component acts on a different part of the spectrum, light changes colour as it goes down: in clear water blue-green remains; in humic water yellow-green remains. This has a practical consequence we will come back to: a PAR sensor without a truly flat spectral response between 400 and 700 nm makes larger errors underwater than in air. The guide on spectral light quality with a spectroradiometer goes deeper into this point.
Euphotic zone
By convention, the euphotic zone extends from the surface to the depth where 1% of the subsurface PAR remains. From the exponential law:
Zeu = ln(100) / Kd ≈ 4.6 / Kd
The 10% light depth is ln(10)/Kd ≈ 2.3/Kd. These thresholds are useful conventions for comparing water bodies; the actual depth at which net primary production reaches zero depends on the community, temperature and vertical mixing.
What about the Secchi depth?
Two empirical relationships appear in almost every Brazilian limnology paper:
- Kd ≈ 1.7 / ZSD (Poole and Atkins, 1929), where ZSD is the Secchi depth;
- Zeu ≈ 2.7 × ZSD (a factor attributed to Cole, 1994, for tropical regions and widely used in Brazil following Esteves).
Notice that they are the same idea: 4.6 / 1.7 ≈ 2.7. The problem is that the 1.7 factor is not universal. Koenings and Edmundson (1991) found the product Kd × ZSD ranging from about 0.5 to 3.8 among lakes, lower in clay-turbid waters and higher in humic-coloured waters. In Brazil, Padial and Thomaz (2008), at the State University of Maringá, analysed 2,136 paired Secchi and PAR measurements in a large Neotropical reservoir and a floodplain and obtained a mean index of 2.26, significantly different from 1.7, together with a non-linear model (Kd = 2.00 × ZSD^−0.76) that was more reliable for those systems. Lee et al. (2018) further showed that part of the disagreement between studies comes from where Kd was measured: in the uppermost layer it is usually much larger than in deeper layers, especially in clear waters.
The lesson is straightforward: if your research question depends on light, measure light, and use the measurements to fit the Secchi relationship for your own water body rather than importing 1.7.
How a submersible PAR logger works
A submersible PAR logger is essentially a quantum sensor (cosine-corrected diffuser, filter and photodetector) inside a watertight housing, with its own logging electronics and battery. It stays moored for weeks or months and is recovered to download the data. Three design features deserve attention when choosing a logger and writing the methods section.
Integrating versus instantaneous sampling
Some loggers take a spot reading at each interval; others integrate light over the whole interval and store the sum. Underwater, in shallow water, the wavy surface acts as a set of lenses and produces very intense and very short flashes of light (wave-focusing flicker). An instantaneous reading may happen to fall on a flash or a shadow and add huge noise. An integrating logger "sees" the average over the whole interval, which is exactly what matters for photosynthesis and daily light.
Count saturation
Integrating loggers usually accumulate a digital count with a maximum value. If the interval is too long and the light too strong, the count saturates and the data for that interval are truncated. In shallow tropical waters, and in tests in air at summer noon, this risk is real; choose the interval with that in mind.
Factory or user calibration
Some sensors leave the factory with a calibration certificate in µmol m⁻² s⁻¹; others deliver raw counts and require user calibration against a reference. Neither option is wrong, but the second must be planned in the schedule and described in the methods.
The immersion effect: why an air-calibrated sensor reads low in water
This is the most neglected point in underwater light measurements. The refractive index of water (about 1.33) is higher than that of air (1.00). When the sensor's diffuser is submerged, a larger share of the light entering the diffuser is scattered back out, and less light reaches the photodetector. A sensor calibrated in air therefore reads low underwater (Smith, 1969; Tyler and Smith, 1970).
The correction is a multiplier called the immersion effect correction factor. It depends on the geometry and material of the diffuser, so it is specific to each sensor model. As an order of magnitude: Apogee Instruments determined in the laboratory factors of 1.08 for an older quantum sensor model and 1.32 for a full-spectrum model with different optics (Blonquist, Nitzel and Bugbee), and today publishes values of 1.15 to 1.25 for its current models. In other words: without correction, the same water body can look 8% to more than 30% darker, depending on the sensor.
The laboratory method described by Zibordi et al. (2004), and used by Apogee, can be reproduced at a university: a stable lamp above a tank of clean water, the sensor measured in air and then at several shallow depths, with a geometric correction, extrapolation of the reading to zero depth and division by the surface transmittance.
The most important teaching point is knowing when the immersion effect matters and when it cancels out:
| What you calculate | Does the immersion effect matter? | Why |
|---|---|---|
| Kd from two or more identical submerged sensors | No | It is a ratio of underwater readings; the factor appears in numerator and denominator and cancels |
| Euphotic zone depth from Kd | No | Derived from Kd only |
| Light fraction at one depth relative to another submerged depth | No | Also a ratio between submerged sensors |
| Light fraction at a depth relative to the weather station in air | Yes | One term is in air, the other in water |
| Absolute PPFD or daily light at the bottom (mol m⁻² day⁻¹) | Yes | It is an absolute value; it must be in true units |
| Comparison with published physiological thresholds (macrophytes, corals, seagrasses) | Yes | Thresholds are in absolute units |
If the manufacturer of your logger does not publish an immersion factor, there are three honest options: work only with relative quantities (Kd, Zeu and ratios between submerged sensors); determine the factor in the laboratory as described above; or run an in-water intercomparison, at the same depth, against an underwater quantum sensor already calibrated for submerged use. Whichever you choose, it must be stated in the methods.
Calibrating and intercalibrating the loggers
Absolute calibration in air against a reference
When the logger delivers raw counts, the simplest calibration is to place it side by side with a reference quantum sensor, in air, in full sun, without either shading the other, and with the same integration interval. Good practice is to cover the whole day, from sunrise to sunset, so the factor represents the full range of solar angles and intensities. Because the output is zero in the dark, calibration is single-point: the factor is in practice the ratio between the reference average and the count average over the same period. Saturated intervals must be discarded or, better, the test repeated with a shorter interval.
Three precautions:
- Use a reference with a current certificate and record its model, serial number and calibration date.
- Prefer clear or steadily partly cloudy days, and also compute the factor using only the central hours of the day to check whether both values agree.
- Keep the raw data (counts) together with the converted values. If the calibration is revised, the series can be reprocessed.
Intercalibration between loggers
To compute Kd from two loggers, more important than each one's absolute calibration is that both read the same when they receive the same light. Before deployment, leave all loggers together, in air, side by side and level, for one to three days, and compute each one's daily ratio against the group average. If you can, repeat the test in a shallow tank, all at the same depth, to check immersion as well. After recovery, repeat the intercomparison: if the ratio has changed, you have a measure of drift and of the fouling accumulated over the period.
Setting up the field campaign
Where and at what depth
- Define the question first. For Kd and euphotic zone, use at least two sensors in the water column, separated by a depth difference that produces a clear light reduction (ideally so that the lower sensor receives something between 10% and 50% of the light at the upper sensor). Three or more depths let you fit a line of ln E against z and check whether attenuation is homogeneous.
- For bottom light (macrophytes, benthos, reefs), a sensor next to the substrate, at the height of the leaves or colony, is what matters; add a shallow sensor to obtain Kd.
- Record depth relative to the surface, not to the bottom. In reservoirs, the water level can vary by metres within a dry season. Sensors fixed to a structure on the bottom change depth with the level; sensors hanging below a buoy keep their depth relative to the surface. If you use a fixed structure, log water level with a pressure transducer (see the guide on water level with a pressure transducer and barometric compensation) and recompute each sensor's depth at every interval.
Mounting
- Sensor facing up and level. Permanent tilt introduces cosine error; buoys that swing a lot add noise.
- Avoid shading from buoys, ropes, piers and the support boat. In Brazil, for most of the year and especially outside the tropics, the sun passes to the north; mount the sensor on the north side of the support structure, away from it.
- Use a suitable anchor and line, with identification and a second safety tie. Losing the logger means losing the entire series.
- Record everything in the field notebook: coordinates, deployment depth, water level, Secchi depth, time, sky condition and photos.
Biofouling: the silent enemy
In productive tropical waters, a film of algae, bacteria and sediment can form on the diffuser within a few days. The effect is a slow, progressive drop in readings, easily mistaken for increasing turbidity. The defences are:
- Periodic cleaning of the diffuser with a soft cloth or gentle brush, recording date and time (before and after cleaning, the reading should show a jump if there was fouling).
- A mechanical wiper, when one is available for the model.
- A shallow control sensor, cleaned more often, for comparison.
- A check against the weather station, as explained below: if the ratio between underwater light and station light drops steadily for weeks without rain, without strong wind and with a stable Secchi depth, suspect fouling.
Logging interval and memory
For daily Kd and daily light, intervals of 10 to 15 minutes are usually a good compromise between resolution, memory and battery. Before deployment, run a noon test in air with the chosen interval to confirm there is no saturation. And do not change the interval mid-campaign without documenting it: in some systems the calibration is applied taking the interval into account, and a change alters the conversion of older data.
From raw data to Kd: step-by-step calculation
1. Convert and integrate
Apply the calibration factor (and, if the analysis requires absolute values, the immersion factor). For daily light, sum PPFD × interval length over the day:
DLI (mol m⁻² day⁻¹) = Σ PPFD (µmol m⁻² s⁻¹) × Δt (s) / 10⁶
2. Compute Kd between two depths
Kd = ln(E₁ / E₂) / (z₂ − z₁)
where E₁ and E₂ are the light at depths z₁ (shallower) and z₂ (deeper). Use daily totals or the sum over the central hours of the day (for example, 10:00 to 14:00); avoid single readings and very low sun angles, when the light path in water becomes longer and apparent Kd increases.
3. With three or more sensors, fit a line
Regress ln(E) against z: the slope is −Kd and the coefficient of determination shows whether the water column is homogeneous. Always report the depth range used, because Kd for the 0–0.5 m layer can be very different from Kd for 1–3 m.
Worked example (illustrative values)
Consider a reservoir with two intercalibrated loggers hanging below a buoy at 0.5 m and 2.0 m below the surface. On a summer day the daily totals were:
- E(0.5 m) = 14.2 mol m⁻² day⁻¹
- E(2.0 m) = 5.2 mol m⁻² day⁻¹
Then:
- Kd = ln(14.2 / 5.2) / (2.0 − 0.5) = 1.005 / 1.5 ≈ 0.67 m⁻¹
- Zeu = 4.6 / 0.67 ≈ 6.9 m
- 10% light depth ≈ 2.3 / 0.67 ≈ 3.4 m
- Fraction of subsurface light reaching 2 m: e^(−0.67 × 2) ≈ 26%
On the same day the Secchi depth was 2.4 m. Compare the estimates:
| Method | Kd (m⁻¹) | Zeu (m) |
|---|---|---|
| Loggers (measured) | 0.67 | 6.9 |
| Poole and Atkins, Kd = 1.7 / ZSD | 0.71 | 6.5 (2.7 × ZSD) |
| Padial and Thomaz, index 2.26 / ZSD | 0.94 | 4.9 |
| Padial and Thomaz, Kd = 2.00 × ZSD^−0.76 | 1.03 | 4.5 |
In this illustrative case, the measured product Kd × ZSD is 1.61, close to 1.7; the models fitted for other Neotropical systems (with Kd measured in the 0–0.2 m layer) would give a euphotic zone up to one third shallower. None of the formulas is "wrong": each one describes the water and the layer in which it was fitted. That is why it is worth measuring.
Now for absolute light at 2 m. If the nearby weather station recorded 38 mol m⁻² day⁻¹ of PAR in air and we assume (illustratively) that 95% crosses the surface, the estimated light at 2 m would be 38 × 0.95 × 0.26 ≈ 9.5 mol m⁻² day⁻¹. This value can only be compared with the 2 m logger after applying the immersion factor to the logger; without it, the submerged sensor will show a lower number, and the difference will wrongly be attributed to the water.
Combining with the weather station
The weather station is the reference that turns an underwater light series into interpretable information. The most useful combinations:
- PAR or solar radiation at the surface. Dividing underwater light by station light (for the same interval) gives the transmitted fraction, which removes the effect of clouds and season. A drop in bottom light on a cloudy day is not a change in the water; a drop in the transmitted fraction is. If the station has only a pyranometer, PAR can be estimated from global radiation, but with larger uncertainty; ideally, install a quantum sensor at the station.
- Rain. Kd pulses right after intense rainfall indicate sediment input from the catchment. Combining this with rainfall intensity (see the guide on the tipping bucket rain gauge) and with tributary discharge helps quantify the effect.
- Wind. In shallow lakes and reservoirs, strong gusts resuspend bottom sediment and raise Kd for hours or days. The station's wind series explains these events and helps distinguish them from fouling.
- Dissolved oxygen. Daytime oxygen production follows the light available in the water column. Measuring light and dissolved oxygen with an optical sensor on the same buoy makes it possible to estimate metabolism and photosynthesis–irradiance relationships in situ.
- Quality control. The same QC principles as for the station (physical limits, temporal consistency, comparison with neighbours) apply to underwater light: light in water cannot exceed light in air, must be zero at night and should vary consistently with the transmitted fraction. The guide on the integrated weather station and data quality control provides an applicable checklist.
Applications in Brazilian research
- Reservoirs and lakes. Euphotic zone, trophic state and the link with cyanobacterial blooms; local fitting of the Secchi–Kd relationship; effect of rainfall and level changes on available light.
- Floodplains and Amazonian rivers. The white, black and clear waters of Sioli's classic classification have radically different light regimes, dominated respectively by sediment, by humic matter and by the water itself. A submersible logger makes it possible to measure these differences over the flood pulse.
- Submerged macrophytes. The maximum colonisation depth of submerged plants is strongly controlled by bottom light; measuring daily light at the lower edge of the beds is more informative than the Secchi depth.
- Aquaculture. In ponds, light in the water column regulates daytime oxygen production by phytoplankton and, indirectly, the risk of night-time hypoxia.
- Coastal and reef environments. Seagrass meadows, rhodolith beds and corals depend on a minimum fraction of surface light; in a classic review, Duarte (1991) showed that seagrasses colonise, on average, down to the depth receiving about 11% of surface light. To compare with thresholds of this kind, absolute values (with immersion correction) are essential.
Catalogue example: submersible Bluetooth PAR logger
In the HenSistemas catalogue, the submersible Bluetooth PAR logger (ref. EIC-OXLPAR, Odyssey Xtreem line made by Dataflow Systems, New Zealand) is a standalone PAR logger with a cosine-corrected photosynthetic irradiance sensor from 400 to 700 nm, an internal temperature sensor, IP68 protection and submersion to 30 m. Data are downloaded via Bluetooth Low Energy to a phone or tablet app and sent to a cloud portal under an annual data subscription (the product page states that the purchase includes one year). According to the product page and the manufacturer's datasheet, memory holds 60,000 records (including temperature) and the battery, two AA alkaline cells, lasts about two years at a 15-minute logging interval.
Several points in the manufacturer's documentation are directly relevant to this guide:
- It is an integrating logger. The datasheet describes it as a light logger that integrates the signal over the interval, which is an advantage against wave flicker in shallow water.
- It is not factory calibrated. The manual and datasheet state that the logger delivers a count and must be user-calibrated against a reference PAR meter, with the same integration interval (the manufacturer suggests 5 minutes or more) and, preferably, a full sunny day. The calibration is applied in the portal as a scale factor, and raw data are preserved. The maximum count per interval is 65,535; saturated readings require repeating the test with a shorter interval.
- The manufacturer does not publish an immersion factor, spectral response curve or cosine error. Because the recommended calibration is done in air, submerged readings should be treated as relative (excellent for Kd and Zeu) until the immersion factor is determined as described above.
- Temperature is measured inside the logger. When submerged it records the surrounding water temperature; in air, in the sun, housing heating makes this reading unreliable during the day. The accuracy stated in the datasheet is ±0.5 °C typical (±2.0 °C maximum): useful as complementary information, but no substitute for a thermistor chain when studying stratification.
- To download data, the logger must be taken out of the water, since Bluetooth does not propagate underwater. Plan download visits together with cleaning visits.
- An optional mechanical wiper is available from the manufacturer to reduce fouling.
Comparing the website product page with the manufacturer's latest documentation (datasheet version 10/25), there are differences worth confirming when requesting a quote: the product page gives an operating range of −20 to 85 °C, while the manufacturer gives −20 to 55 °C for the standard version and up to 85 °C only for the industrial version; the product page mentions Android 6.0, whereas the current datasheet requires Android 8.0 or later and adds iOS support; and the temperature resolution stated by the manufacturer is 0.0625 °C. The HenSistemas team confirms the version, the data subscription price and accessories (mounting bracket and wiper) in the quotation.
Related products
- Submersible IP68 PAR logger, classic line (ref. EIC-ODYPARW): earlier version of the submersible logger, with 16,350-reading memory, intervals from 10 seconds to 12 hours and lithium batteries.
- PAR logger for use in air (ref. EIC-ODYPAR): IP66, non-submersible version, useful as a surface reference on a bank or platform.
- LightScout handheld quantum meters (ref. 3415F): PPFD readers with ±5% accuracy, useful as a field reference to calibrate and check the loggers in air.
- LightScout quantum PAR sensor (ref. 3668I): 0–2500 µmol m⁻² s⁻¹ sensor with analogue output, for measuring surface PAR at the weather station.
- Aranet wireless PAR sensor: PPFD sensor with long-range transmission to a base station, an alternative surface reference where cabling is impractical.
- Miniature temperature, humidity and light logger: measures light in lux and in colour channels; it can indicate relative patterns, but lux is not PAR and requires cross-calibration (Long et al., 2012) before any quantitative use.
- MANTA PLUS multiparameter probe: configurations with turbidity and other optical sensors, to explain why Kd changed.
- Trimeter multiparameter probe: accepts turbidity, chlorophyll a and blue-green algae sensors, the main drivers of light attenuation in reservoirs.
See also the guides Water quality: what to monitor? and Data logger: how to choose the right one.
Checklist before deployment (and before publication)
- Does the question require absolute light values, or are Kd and euphotic zone enough?
- Were the loggers calibrated against a reference with a current certificate, and is the factor recorded with serial number and date?
- Were the loggers intercalibrated side by side before and after the campaign?
- If absolute values are used, was the immersion factor determined or obtained from the manufacturer, and is it described in the methods?
- Was the logging interval tested at noon without saturation, and kept constant?
- Is each sensor's depth referenced to the surface, with correction for level changes?
- Is there a diffuser cleaning routine, with dates, and a criterion for identifying fouling?
- Does the nearest weather station measure PAR (or solar radiation), rain and wind at the same interval?
- Was the Secchi depth measured at each visit, to fit the local Secchi–Kd relationship?
- Does the text report the depth range used for Kd, the calculation method (two points or regression) and the period (daily or central hours)?
References
- Blonquist, M.; Nitzel, D.; Bugbee, B. Underwater measurement of photosynthetically active radiation (PAR): immersion effect correction factors for Apogee quantum sensors. Apogee Instruments, Logan (USA). See also the page Underwater PAR measurements.
- Cole, G. A. Textbook of limnology. 4th ed. Prospect Heights: Waveland Press, 1994.
- Dataflow Systems. Odyssey Xtreem Photosynthetic Active Radiation Logger — Datasheet (V 10/25) and Odyssey Xtreem PAR Logger — User Manual (V 03/21). Christchurch, New Zealand.
- Duarte, C. M. Seagrass depth limits. Aquatic Botany, v. 40, p. 363–377, 1991.
- Esteves, F. A. (coord.). Fundamentos de limnologia. 3rd ed. Rio de Janeiro: Interciência, 2011.
- Kirk, J. T. O. Light and photosynthesis in aquatic ecosystems. 3rd ed. Cambridge: Cambridge University Press, 2011.
- Koenings, J. P.; Edmundson, J. A. Secchi disk and photometer estimates of light regimes in Alaskan lakes: effects of yellow color and turbidity. Limnology and Oceanography, v. 36, n. 1, p. 91–105, 1991. DOI: 10.4319/lo.1991.36.1.0091.
- Lee, Z.; Shang, S.; Du, K.; Wei, J. Resolving the long-standing puzzles about the observed Secchi depth relationships. Limnology and Oceanography, v. 63, n. 6, p. 2321–2336, 2018. DOI: 10.1002/lno.10940.
- Long, M. H.; Rheuban, J. E.; Berg, P.; Zieman, J. C. A comparison and correction of light intensity loggers to photosynthetically active radiation sensors. Limnology and Oceanography: Methods, v. 10, p. 416–424, 2012. DOI: 10.4319/lom.2012.10.416.
- Padial, A. A.; Thomaz, S. M. Prediction of the light attenuation coefficient through the Secchi disk depth: empirical modeling in two large Neotropical ecosystems. Limnology, v. 9, p. 143–151, 2008. DOI: 10.1007/s10201-008-0246-4.
- Poole, H. H.; Atkins, W. R. G. Photo-electric measurements of submarine illumination throughout the year. Journal of the Marine Biological Association of the United Kingdom, v. 16, p. 297–324, 1929.
- Smith, R. C. An underwater spectral irradiance collector. Journal of Marine Research, v. 27, p. 341–351, 1969.
- Tyler, J. E.; Smith, R. C. Measurements of spectral irradiance underwater. New York: Gordon and Breach, 1970.
- Zibordi, G.; Hooker, S. B.; Mueller, J. L.; Lazin, G. Characterization of the immersion factor for a series of in-water optical radiometers. Journal of Atmospheric and Oceanic Technology, v. 21, p. 501–514, 2004.
- HenSistemas product page: submersible Bluetooth PAR logger.
Instruments for this application

DataFlow-SystemsEIC-OXLPAR
Xtreem Photosynthetic Active Radiation Logger

DataFlow-SystemsEIC-ODYPARW
Submersible Photosynthetic Active Radiation Logger (Submersible to 30m)

DataFlow-SystemsEIC-ODYPAR
Waterproof Photosynthetic Active Radiation Logger

Spectrum Technologies3415Fxxx
LightScout Quantum Meters

Spectrum Technologies3668I
LightScout Quantum PAR Light Sensor

AranetTDSKAR01
Aranet Wireless PAR Light Sensor

HenSistemasHSWTG0021
HSWTG0021 Miniature Submersible Temperature, Humidity and Light Data Logger

EUREKA water probesMANTA-PLUS
MANTA PLUS Multiparameter Probe with up to 12 Sensors

EUREKA water probesTrimeter