Meteorology · Agriculture · Technical guides
Wind measurement at the weather station: how to choose and install an anemometer for research
A teaching guide to wind measurement: WMO conventions (10-minute means, 3-second gusts, true north), cup versus ultrasonic anemometers, height and exposure, FAO-56 conversion to 2 m, magnetic declination in Brazil, maintenance and selection criteria for research.

Wind is the weather station variable that depends most on where and how the sensor is installed. A poorly shielded thermometer is off by a few tenths of a degree; an anemometer placed behind a shed, on a roof or on a short mast may record only a fraction of the real wind, and no post-processing can recover what was never measured. At the same time, wind speed and direction feed analyses that are central to research in Brazil: FAO-56 evapotranspiration, spraying windows and drift risk, dispersion of pollutants and odours, thermal comfort, structural loads and wind energy assessment.
This guide explains, step by step, what measuring wind means under the recommendations of the World Meteorological Organization (WMO, guide WMO-No. 8), the practical differences between cup and ultrasonic anemometers, how to choose height and site, how to deal with magnetic north and how to set up averages and gusts on the data logger.
What exactly is measured
A surface station measures the horizontal wind: a vector with magnitude (speed) and direction. Three WMO conventions prevent most of the confusion:
- Direction is where the wind comes from, in degrees measured clockwise from true (geographic) north. A 90° wind blows from east to west.
- For synoptic purposes, speed and direction represent a 10-minute average.
- Calm is reported when the mean speed is below 0.2 m/s; in that case, direction has no physical meaning.
Beyond the mean, many applications need wind variability. The WMO recommends two quantities for routine use: the standard deviation of speed and direction, and the 3-second peak gust, that is, the highest 3 s running average within the period (for instance, the last hour). A 1-second gust and a 3-second gust are not comparable, so the gust duration must be stated in the methods.
As for accuracy, the WMO guide considers an uncertainty of 0.5 m/s below 5 m/s and 10% above 5 m/s, and 5° in direction, sufficient for most uses. Modern sensors meet these figures comfortably; what usually fails is exposure, the subject of the next sections.
Scalar or vector mean?
There are two ways to average wind, and they give different results:
- Scalar mean: mean speed is the average of the magnitudes, regardless of direction.
- Vector mean: each reading is split into east-west and north-south components (U and V), each component is averaged, and only then are the resulting speed and direction computed.
The difference shows up when direction fluctuates. Picture two readings of equal speed, one from 350° and one from 10°. The arithmetic mean of the angles is 180°, a southerly wind, when the real wind came from the north. The vector mean correctly gives 0°. For direction, always use a vector mean (or an algorithm that handles the 0°/360° crossing). For speed, the scalar mean is the most common in agrometeorology, and the vector mean comes out lower when direction varies a lot. What matters is to state in the methods which one was used.
Cups and vane, or ultrasonic?
Cup anemometer and wind vane
This is the classic arrangement, historically used at INMET stations in Brazil. The cups turn at an angular speed proportional to the wind and produce pulses or a voltage with proportional frequency; the vane drives a potentiometer or encoder that gives direction.
Points to understand before choosing:
- Starting threshold. Below a certain speed the rotor does not turn. In moderately priced sensors this threshold is around 1 m/s, so light winds, common at night and in low-lying areas, are under-represented.
- Distance constant (response length). How many metres of air must pass before the rotor responds to a change in speed. The smaller it is, the better the sensor follows gusts.
- Overspeeding. Cups accelerate faster than they slow down, and vertical fluctuations change the interference between them. The WMO notes that overestimation of the mean can reach 10% for some designs in turbulent wind.
- Vane damping. The WMO considers a damping ratio between 0.3 and 0.7 adequate, so the vane neither oscillates too much nor responds too slowly.
- Wear. Bearings collect dust and corrosion, which raises the threshold over time. In dusty farmland or near the sea, inspections must be more frequent.
On the plus side, the mechanical system is simple, draws little power, has a signal almost any logger can read and a long record of comparison with historical series.
Ultrasonic anemometer
An ultrasonic anemometer measures the time of flight of sound pulses between pairs of transducers a fixed distance apart. Sound travels faster with the wind and slower against it; the difference between outbound and return times on two orthogonal axes gives the U and V components directly and, from them, speed and direction.
Practical consequences:
- No moving parts: no bearings to wear and no mechanical starting threshold, which improves the measurement of very light winds. The WMO highlights high durability and little accuracy deterioration over time.
- No inertia: response is practically instantaneous, useful for gusts and turbulence studies.
- Native U-V components: they simplify vector averaging and model integration.
- Power: baseline consumption is low, but anti-icing heating, where fitted, can multiply it. In most of Brazil heating is unnecessary; it makes sense at high-altitude sites prone to freezing and must be included when sizing the solar panel and battery.
- Clear acoustic path: dirt, insects or nests between the transducers degrade the measurement, so visual inspection is still required.
A rule of thumb for research: cups and vane serve agrometeorological studies and networks that need comparability with older series well; the ultrasonic sensor is preferable when light winds matter (nights, thermal inversions, odour and spray dispersion), when field maintenance is difficult, or when you want to work with high-resolution components and gusts.
Height and exposure: what weighs most on the data
Wind increases with height, much more so over rough terrain. That is why the WMO sets a standard height of 10 m over open terrain, defined as terrain where any obstacle is at least 10 times its height away. Because the wake of trees and buildings can extend 12 to 15 heights downwind, that distance is the minimum, not the ideal. INMET automatic weather stations follow this standard, with the wind sensor on top of a 10 m mast.
In the field:
- Prefer the top of the mast. If the sensor has to sit beside a tower, use a boom at least three tower widths long (WMO).
- Roofs are a last resort. On buildings, the WMO recommends raising the sensor at least one building width above the top. Manufacturers give similar criteria, such as mounting at a height of at least 1.5 times the smaller of the building height and the longest roof diagonal.
- Rigid, vertical mast. Mast oscillation becomes noise in the signal and, on sensors with a built-in rain gauge, false tips.
- Away from magnetic fields when the sensor uses an internal compass: motors, transformers, power cables and radios disturb the reference.
- Document the surroundings. The WMO recommends a map within a 2 km radius showing obstacles, vegetation and relief, plus a record of changes such as new buildings or growing trees. Photos of the four quadrants at every visit are the cheapest way to do this.
What if the study needs wind at 2 m?
In agrometeorology, wind is often measured at 2 or 3 m, and the FAO-56 evapotranspiration method uses speed at 2 m. If your station measures at another height, FAO-56 (equation 47) gives a logarithmic-profile conversion valid over short grass:
u₂ = u_z × 4.87 / ln(67.8 × z − 5.42)
For z = 10 m the factor is about 0.75: a wind of 3.2 m/s at 10 m corresponds to about 2.4 m/s at 2 m. The conversion assumes a uniform, low surface; over tall crops, orchards or near obstacles it can be badly off, and measuring directly at the height of interest is safer. When using INMET station data, remember that they come from 10 m.
Magnetic north is not true north
Wind direction must be referenced to true north, but compasses, including those built into some ultrasonic anemometers, point to magnetic north. The difference between the two is the magnetic declination, and in Brazil it is large: according to the World Magnetic Model WMM2025, declination in Brasília is about 20° west. Ignoring it rotates the whole wind rose.
The correction is simple: true azimuth = magnetic azimuth + declination, with declination negative when it is west. With a declination of −20°, a magnetic reading of 90° corresponds to 70° true.
Good practice:
- Compute the declination for the coordinates and date of installation (WMM-based calculators or the Brazilian National Observatory service) and record the value in the metadata.
- On mechanical vanes, align zero with true north using a reliable reference (GNSS, solar alignment or a landmark of known azimuth), not the compass alone.
- On sensors with a built-in compass, check in the manual whether the output refers to magnetic north and where the correction should be applied: in the sensor, in the logger or in post-processing.
- Recheck alignment whenever the mast is taken down or the sensor replaced.
Logger setup: averages, gusts and metadata
Final quality also depends on how the logger samples and summarises the signal. A WMO-consistent setup includes:
- Frequent sampling, every 1 s or faster, to compute 3 s gusts. As a reference, the WMO describes sampling the signal every 0.25 s.
- 10-minute means of speed and direction (vector mean for direction), plus the standard deviation.
- 3 s peak gust and its direction for each logging interval.
- A single unit, preferably m/s (km/h = m/s × 3.6; 1 knot ≈ 0.514 m/s).
- Metadata: sensor height, type and serial number, declination used, averaging method, maintenance dates and photos of the surroundings.
Also check the sensor's default behaviour. Some ultrasonic sensors ship with a 1 s averaging period, or compute the gust as the maximum between two consecutive logger polls; in that case the polling interval defines the gust window. Another common setting is the speed threshold below which direction is frozen at its last value, to avoid random directions in calm conditions.
Maintenance and quality control
- Visual inspection at every visit: physical damage, mast verticality, cables and connectors.
- Mechanical sensors: following the WMO, check zero by holding the cups, verify vane orientation by holding it in known positions, and look for signs of bearing friction, such as stepped records and poor sensitivity in light winds. Repairs are usually only feasible in a workshop.
- Ultrasonic sensors: keep the path between transducers clear and periodically confirm the north reference.
- Calibration: reliable anemometer calibration is done in a wind tunnel; with the instrument in good condition, the manufacturer's calibration is adequate for most uses. For projects with metrological requirements, ask for a traceable certificate. In the field, side-by-side comparison with a calibrated anemometer is the alternative the WMO suggests.
- Data quality control: look for values that stay constant for hours (stuck sensor), direction with no variation, zero speed with positive gusts, and jumps after maintenance. Comparing with the nearest INMET station, allowing for differences in exposure, helps detect drift.
As with any research variable, keep the raw data and log everything done in the station notebook.
An example from the catalogue
In the HenSistemas catalogue, the Delta OHM two-axis ultrasonic anemometer (HD52.3D series) illustrates these criteria well. According to the manufacturer's datasheet, it measures speed from 0 to 60 m/s with 0.01 m/s resolution and an accuracy of ±0.2 m/s or ±2%, whichever is greater, up to 35 m/s (±3% above that); direction covers 0 to 359.9° with 0.1° resolution and ±2° accuracy (RMSE) from 1.0 m/s. The instrument also outputs U-V components and gusts (with the MODBUS-RTU and SDI-12 protocols, computed as the maximum 3 s average between two readings), and the averaging interval can be set from 1 s to 10 min, with a choice of scalar or vector mean.
For integration there are RS232, RS485, RS422 and SDI-12 serial outputs with NMEA, MODBUS-RTU and SDI-12 protocols, plus two factory-configured analogue outputs (4–20 mA, 0–1 V, 0–5 V or 0–10 V). Power supply is 10 to 30 Vdc, drawing 26 mA at 24 Vdc without heating; with the optional heater, consumption reaches 8 W. Protection is IP66, the operating range is −40 to +70 °C and the stated survival speed is 90 m/s. An internal magnetic compass compensates the instrument's orientation; since it refers to magnetic north, the declination correction must be planned into data processing.
Versions of the series can add temperature and relative humidity, barometric pressure, and either global solar radiation or rainfall (these last two are mutually exclusive). It is a compact solution, but bear in mind that the WMO standard calls for different heights for each variable: wind at 10 m, temperature and humidity between 1.25 and 2 m. On a 10 m mast, the integrated sensors measure temperature and humidity at 10 m; on a short tripod, wind is measured below the standard height. Decide first which variable is the priority in your study. The manufacturer also states that all sensors are factory calibrated and offers, as an option, ILAC-MRA traceable calibration (ACCREDIA).
Related products
- Thermoplastic cup anemometer and wind vane set (Wind Sentry line): a mechanical sensor with a 1.1 m/s cup starting threshold and potentiometer direction output; a good option for agrometeorological stations and teaching.
- Combined wind speed and direction sensor: cups and vane in a single unit, with RS485 or 4–20 mA output, for environmental monitoring networks.
- Heated 2D ultrasonic anemometer: no moving parts, with RS485, SDI-12 and 4–20 mA outputs.
- Compact low-power ultrasonic anemometer: an option for remote stations running on solar power.
- Weather station data logger with 4G transmission: SDI-12 master and RS485 MODBUS-RTU ports, measurement intervals from 1 s, and data delivery by FTP, e-mail or cloud.
For the full picture, see also the guides How to choose a weather station, Compact weather stations with no moving parts and Data logger: how to choose the right one.
Checklist before requesting a quote
- What will the wind data be used for: evapotranspiration, spray drift, dispersion, structural loads or wind energy? This sets height, averaging and the need for gusts.
- At what height do you need the data (10 m, 2 m or several heights), and does the site allow the recommended exposure, with obstacles at least 10 times their height away?
- Do light winds matter to the study? If so, consider an ultrasonic sensor or check the starting threshold of the mechanical one.
- Can the logger read the sensor's signal (pulses, potentiometer, 4–20 mA, RS485 Modbus or SDI-12) and compute 10-minute means and 3 s gusts?
- How will the true-north reference be established, and where will declination be corrected?
- Is there enough power, especially with heating? Who will handle maintenance and metadata?
Answering these questions before the quote avoids discovering, months later, that the wind series cannot support the planned analysis. If you would like help matching your research protocol with the catalogue, talk to the HenSistemas team.
Instruments for this application

DeltaOhm - GHM GroupHD52.3D
HD52.3D Series – 2-Axis Ultrasonic Anemometer

EIC-03002
Wind Sentry Anemometer and Vane

EIC28120-01
Wind Speed & Direction Combined Wind Sensor

HenSistemasHS-EDS282E
HS-EDS282E 2D Ultrasonic Wind Speed and Direction Anemometer

HenSistemasHS14WDC2E
HS14WDC2E Ultrasonic Anemometer

DeltaOhm - GHM GroupHD33MT.4


