PV module soiling in research: how to measure soiling losses with a clean and soiled reference sensor and combine the data with the weather station
A teaching guide to soiling in photovoltaic systems: soiling ratio, level and rate, the IEC 61724-1 clean and soiled reference device pair method, temperature correction, sensor types and their uncertainties, the role of rain, dew, wind and particulate matter, research results from Brazil, installation, cleaning decisions and quality control.

A brand-new photovoltaic module, on its first day of operation, delivers what the datasheet promises under site conditions. A few weeks later, with no electrical fault at all, it already delivers less. The cause is usually visible to anyone who climbs onto the roof or walks through the plant: a film of dust, soot from fires, pollen, sea salt or bird droppings on the glass. This phenomenon has a technical name, soiling, and it is one of the most variable and least measured losses in solar generation. Variable because it depends on the soil, wind, rain, dew and human activity around the site; rarely measured because many installations still decide when to clean "by eye" or by the calendar.
This guide is for lecturers, graduate students and researchers at universities and public institutes working in solar energy, applied meteorology, agricultural engineering or plant maintenance. We explain what the soiling ratio is, how the IEC 61724-1 standard requires it to be measured, the types of sensors and the uncertainty of each, why the weather station is essential to interpret the data, what Brazilian research has already measured, how to install the sensor, how to process the series and how to turn the number into a cleaning decision.
What soiling is and why it matters
The particle layer on the glass reduces the number of photons reaching the cells through three optical mechanisms: absorption, reflection and scattering of the incident light. The electrical effect is a drop in current and therefore in power. If the soiling is uniform, the loss is nearly proportional to the light reduction. If it is not uniform, the problem gets worse: a build-up along the lower edge of the module, common on tilted modules after light rain, can shade an entire row of cells, activate the bypass diode and cut power far more than the short-circuit current suggests.
The scale of the problem is large. Report IEA-PVPS T13-21:2022, from the photovoltaic power systems programme of the International Energy Agency, estimates that in 2018 soiling cost at least 3 to 4% of annual photovoltaic energy production worldwide, an economic loss in the order of 3 to 5 billion euros, with an upward trend because more and more plants are being built in sunny, dry regions. The same report lists cases of mean daily losses of 4.4% in Málaga, more than 20% during long dry periods, and almost 46% over three months without cleaning in Kuwait.
For research, soiling matters for at least four reasons:
- System performance. Without separating the soiling loss, a drop in performance ratio cannot be correctly attributed to module degradation, the inverter or temperature.
- Operation and maintenance. Deciding when to clean is an optimisation problem between cleaning cost and lost revenue, and it depends on a reliable measurement.
- Environmental science. The deposition rate integrates aerosols, wind, humidity and rain; it links solar energy to meteorology and air quality.
- Materials. Anti-soiling coatings, textured glass and tilt angles can only be compared with a standardised measurement protocol.
Soiling ratio, level and rate: the three quantities
The IEC 61724-1 standard (Photovoltaic system performance – Part 1: Monitoring) defines the soiling ratio (SR) as the ratio between the power of the array under soiled conditions and the power the same array would deliver if it were clean. It equals 1 with no soiling and decreases as soiling accumulates.
Two quantities derive from it:
- Soiling level, the fractional loss: level = 1 − SR. An SR of 0.95 means a 5% loss.
- Soiling rate, the daily change in SR during a period without cleaning, expressed in %/day and, by convention, negative. A rate of −0.2%/day means that, without rain or cleaning, the system loses about 0.2 percentage points per day.
SR describes the current state of the system; the rate describes the speed at which it gets dirty and, combined with the rainfall regime, makes it possible to predict future losses. A complete study needs both. The literature also uses similar names, such as cleanness index or soiling loss factor; all of them compare the actual output of a device with the expected output if it were clean, but they may be calculated with different data. When comparing papers, check which definition was used.
How IEC 61724-1 requires soiling to be measured
The 2021 edition of IEC 61724-1 introduced a normative annex (Annex C) dedicated to soiling measurement with a pair of photovoltaic reference devices: one kept clean and another left to soil naturally, like the array. In Class A (high accuracy) monitoring systems, soiling ratio measurement is required when the expected soiling losses at the site exceed 2%, with a maximum sampling interval of one minute. The elements of the method are:
- Equipment. Two similar devices (reference cells or modules), mounted in the plane of the array, with temperature measurement. The clean device must be cleaned regularly; the IEA report notes that it should ideally be cleaned every morning, because much of the deposition happens at night, and that infrequent cleaning leads to underestimating soiling.
- Normalisation. With both devices clean, the ratio between them is measured to correct small calibration differences.
- Method 1: maximum power reduction. The maximum power (Pmax) of the two devices is compared, corrected for temperature. It also captures the effect of non-uniform soiling.
- Method 2: short-circuit current reduction. The temperature-corrected short-circuit current (Isc) is compared. It is simpler and is the method used by most commercial sensors, but it can underestimate the loss when soiling is not uniform.
- Daily average. A daily value is calculated from readings in a central window of the day. For fixed devices, the recommendation is to use data within two hours of solar noon; for trackers, angles of incidence below about 35°. In the early and late hours, the high angle of incidence exaggerates the loss, and misalignment and shading distort the comparison.
- Renormalisation. Periodically, both devices are cleaned together and the normalisation ratio is redone.
The calculation with short-circuit current
The short-circuit current of a silicon cell increases slightly with temperature. Therefore, before comparing the two devices, each reading is brought to a reference temperature (normally 25 °C), following the procedures of IEC 60891:
Isc,corr = Isc / [1 + α · (T − 25 °C)]
where α is the temperature coefficient of the device's short-circuit current (for crystalline silicon, typically around +0.05%/°C; use the manufacturer's value) and T is the temperature measured on the device. The instantaneous ratio is:
SR = (Isc,corr soiled / Isc,corr clean) / k
where k is the normalisation ratio obtained with both devices clean.
Worked example. At noon, the clean device reads the equivalent of 1000 W/m² at 52 °C and the soiled one 955 W/m² at 54 °C. With α = 0.05%/°C:
- corrected clean: 1000 / (1 + 0.0005 × 27) ≈ 986.7
- corrected soiled: 955 / (1 + 0.0005 × 29) ≈ 941.4
- raw ratio: 941.4 / 986.7 ≈ 0.954
If, at the last normalisation, the two clean devices gave a ratio k = 0.995, SR becomes 0.954 / 0.995 ≈ 0.959, that is, a soiling level of about 4.1%. Note that if the temperature correction were ignored, the two-degree difference between the devices alone would introduce an error of about 0.1 percentage point. It seems small, but the typical soiling rate in much of Brazil is a few tenths of a point per day.
Types of soiling sensor
Commercial systems can be grouped by measurement principle:
- Electrical, cell-cell. Two reference cells, one cleaned automatically or by hand, the other soiled. They are compact, relatively low-cost and easy to install, but the cell may have different glass from the module and does not capture non-uniform soiling across the whole module.
- Electrical, cell-module or module-module. A module of the same model as the array, soiled naturally, compared with a clean cell or another clean module. They represent non-uniform soiling better, especially when they also measure the I-V curve and power, but require more structure and maintenance.
- In-situ I-V curve measurement. Devices that periodically sweep the current-voltage curve of a module in the array itself and calculate Pmax, Isc and Voc, making it possible to estimate soiling from power without a separate reference module.
- Optical. They measure the transmittance or reflection of light through a glass window, or analyse images. They need little or no maintenance and allow several measurement points, but they require calibration to local dust and do not directly measure the electrical effect.
The IEA-PVPS report summarises the estimated uncertainties: the most accurate measurements, 1 to 2%, come from cell-module or module-module configurations measuring power; the same configurations measuring only Isc are around 3 to 5%, because they do not capture non-uniform soiling; and cell-cell Isc configurations and optical methods are around 4 to 7%. The report itself cautions that these values are estimates and that, with careful calibration and filtering, the Isc ratio can reach about ±1%. The teaching point is to separate two things: the instrument uncertainty (what the sensor measures about itself) and representativeness (how far the sensor soils like the array). A manufacturer can declare a low uncertainty for the first; the second depends on the glass, the position, the tilt and the heterogeneity of the plant, and is the responsibility of the experimental design.
The weather station explains soiling
The soiling ratio alone shows how much was lost. To understand why, predict and generalise, you need to measure the agents that deposit and remove particles. That is why a soiling study is, in practice, a micrometeorology study next to the modules.
- Rain. It is the main natural cleaning agent, but not every rain cleans. In Petrolina (Pernambuco), Souza, Lima and Lima Júnior (2022) concluded that rainfall above about 1 mm restored module power and that more than 15 days without rain already reduced efficiency considerably. In Belo Horizonte (Minas Gerais), a study by the PUC Minas group (Costa et al., 2018, cited in later reviews) reported SR falling from 0.98 to 0.86 in the dry season and returning to 1 after rainfall of about 20 mm. The rain threshold that cleans depends on tilt, glass and type of soiling, and can only be estimated with a rain gauge recording intensity and total per event. The widely used model by Kimber et al. (2006) depends precisely on two parameters that come from this measurement: the minimum rainfall threshold that cleans and the grace period after rain.
- Relative humidity and dew. Humidity increases particle adhesion. Night-time dew, favoured by radiative cooling of the glass, wets the dust and produces cementation and crusts that wind does not remove and light rain removes poorly. Air temperature and humidity, measured in a radiation shield, make it possible to calculate the dew point and estimate the hours of condensation.
- Wind. It transports dust, but it can also remove and resuspend it. In the PUC Minas study at Brotas de Macaúbas (Bahia), in a semi-arid climate, wind was the main factor limiting accumulation, keeping SR close to 1 despite the dryness. Speed and direction indicate which dust sources (dirt roads, crops, yards) are upwind.
- Particulate matter. PM10 and PM2.5 are among the best proxies for modelling soiling, according to the IEA, although in Brazil the observed correlations have been weaker than in deserts. A particle sensor next to the experiment helps identify episodes of fires, harvest or construction.
- Plane-of-array irradiance and module temperature. They are needed to filter the data (clear sky, high irradiance) and to calculate the performance ratio, which also allows soiling to be estimated from system output. IEC 61724 recommends cleaning the irradiance sensors used for this weekly. Interestingly, the IEA report cites studies in which dome pyranometers soil less than flat surfaces such as reference cells and modules: the clean pyranometer does not "see" the array's soiling, and that is exactly why it serves as a reference.
If the station is far from the modules, the correlation loses meaning: rain, dew and dust vary over hundreds of metres, especially near roads and fields. Record everything on the same data logger, with the same clock (preferably UTC) and compatible intervals, for example 1 minute for irradiance and soiling and 10 minutes for the other variables.
What Brazilian research has already measured
Brazil has very different climates, and the results confirm that soiling is site-specific.
- Petrolina (Pernambuco), semi-arid. At the University of Pernambuco, Souza, Lima and Lima Júnior (2022) compared a periodically cleaned module with a module left to soil naturally, using a data acquisition system and glass slides to quantify deposition. The largest difference, 18.72% in power, occurred in a dry period, 48 days after a rainfall of only 0.3 mm, and the abstract reports the 18.72% loss after 70 days without significant rain.
- Belo Horizonte (Minas Gerais), Porto Alegre (Rio Grande do Sul) and Brotas de Macaúbas (Bahia). Costa, Kazmerski and Diniz (2021), from PUC Minas in collaboration with NREL, operated soiling monitoring stations in three climate zones, with polycrystalline silicon and cadmium telluride modules. The paper's abstract indicates rates between 0.1 and 0.2%/day in Belo Horizonte; in the corresponding work published in the Revista Brasileira de Energia Solar, the mean ratios there were 0.92 for polycrystalline silicon and 0.94 for CdTe, with dry-season rates of −0.14%/day and −0.20%/day, respectively, calculated with the Theil-Sen estimator. In Porto Alegre, rainfall spread throughout the year kept SR between 0.97 and 0.98. In Brotas de Macaúbas, wind limited accumulation. The difference between technologies was attributed to spectral response: soiling attenuates short wavelengths more.
These studies show two methodological points that apply to any new study: the need to cover at least one complete annual cycle, as the IEA also recommends, and the importance of normalising and adjusting the series with meteorological variables before comparing sites.
In the Brazilian context, it is worth considering soiling sources that the desert literature rarely discusses: smoke and ash from fires in the dry season of the Centre-West and North, agricultural dust from soil preparation and harvest, dirt roads at rural plants, sea salt on the coast, pollen and bird droppings, which form localised and highly non-uniform spots.
Field installation
A soiling sensor only measures what happens to it. The installation is what ensures that this represents the array.
- Same plane as the array. Mount the sensor with the same tilt and azimuth as the modules, on a rigid structure. On trackers, mount it on the tracker itself. Misalignment between the two devices of the pair produces a ratio that varies during the day; symmetrical averaging around solar noon helps cancel part of the azimuth error.
- Representative position. Avoid edges that receive more wind and areas sheltered behind obstacles. In large plants, soiling is not homogeneous: rows near service roads or on the side the dust comes from get dirtier. The IEA report cites variations of 1.5 to 2 times in deposition rate within the same plant, depending on the prevailing wind and the dust sources, and notes that IEC 61724-1 recommends more than one soiling sensor at plants above 5 MW with expected annual losses above 2%.
- No shade. No object may shade the pair at any time of year. Check the solar path in winter, when the Sun is lower.
- Automatic cleaning. For sensors with a pump and spray nozzle, check the maximum length and height of the water line, the tank capacity and the consumption per cycle. Use clean water, preferably demineralised, so as not to leave salt residues on the glass of the reference device.
- Power and communication. Decide whether power will be AC or 24 VDC, how surge protection will be handled and where the data logger will be. RS485 outputs with Modbus RTU are the standard in supervisory systems (SCADA) and in weather station data loggers.
- Temperature at the device. Temperature correction requires the temperature measured on the device, not air temperature.
- Metadata. Record in the field notebook the date and time of every manual cleaning of the array, tank refilling, maintenance and events (nearby fire, construction, harvest). Without these records, a jump in SR is impossible to interpret.
From measurement to cleaning decision
The simplest rule is to clean when the value of the energy lost since the last cleaning exceeds the cost of cleaning. The IEA report describes this criterion through the cost of production losses, the product of lost energy and the energy price. More complete models, such as that of Jones et al. (2016), calculate the optimum interval between cleanings from the cost of each cleaning, the loss curve and the tariff.
A teaching example shows the logic. Suppose, hypothetically, a plant that produces 4500 kWh per day when clean, a constant soiling rate of 0.2%/day and no rain. After t days, the daily loss is 0.002·t, and the accumulated lost energy is approximately 4500 × 0.002 × t²/2 = 4.5·t² kWh. If each cleaning costs the equivalent of C kWh, the mean cost per day of a t-day cycle is (C + 4.5·t²)/t, which is minimum when:
t* = √(2·C / (E·r))
where E is the clean daily output and r the soiling rate. With C equivalent to 2000 kWh, t* ≈ 21 days. If the rate doubles, the interval drops to about 15 days; if cleaning becomes four times more expensive, the interval doubles. In real life, rain restarts the cycle for free, the rate changes with the seasons and the tariff varies; that is why continuous measurement of SR and rainfall is what makes it possible to update the decision instead of fixing a calendar.
Processing and quality control
The raw series from a soiling sensor is noisy. A minimum processing routine:
- Synchronise soiling, irradiance, temperature, rain, humidity and wind on the same clock.
- Filter the data: keep the window within two hours of solar noon (or angle of incidence below about 35° on trackers), high effective irradiance (the IEA report cites the common use of values above 500 W/m²) and clear sky; discard moments of rapid irradiance change due to passing clouds.
- Calculate the daily SR as the mean of the filtered values, or as an irradiance-weighted mean, and record how many points entered each day.
- Detect cleaning events: positive jumps in SR coinciding with rain, manual cleaning or refilling.
- Estimate the soiling rate for each dry period by robust regression, such as the Theil-Sen estimator, using only periods of at least 14 days without cleaning, as suggested by Deceglie et al. (2018). Prefer monthly or seasonal rates to a single annual rate.
- Check the tank and the pump: a failed cleaning lets the reference device get dirty and makes SR "improve" artificially.
- Cross-check with the temperature-corrected performance ratio, calculated with a pyranometer cleaned weekly: if the sensor indicates an 8% loss and the system shows no equivalent drop, investigate the sensor's representativeness.
- Renormalise periodically by cleaning both devices together, and document each renormalisation.
Common mistakes
- Calculating SR with whole-day data, including morning and late afternoon, and overestimating the loss through the angle-of-incidence effect.
- Ignoring the temperature correction between the two devices.
- Cleaning the reference device only now and then and underestimating soiling.
- Installing the sensor at a different tilt from the modules.
- Using the short-circuit current SR to estimate power loss at plants with non-uniform soiling, such as deposits on the lower edge or bird droppings.
- Extrapolating the rate of a dry month to the whole year.
- Comparing papers without checking whether they used soiling ratio, soiling level or another index.
- Forgetting to record manual cleanings of the array.
The automatic soiling sensor in the catalogue
As a concrete example of the clean and soiled pair method with automatic cleaning, the catalogue includes the automatic soiling sensor for photovoltaic panels (ref. 3S-SMS-MB, by Seven Sensor, Türkiye). According to the product page and the manufacturer's catalogue:
- it calculates the soiling rate by comparing the irradiance of two sensors: one exposed to soiling like the modules and another cleaned automatically every day by a pump and spray nozzle, which follows the recommendation of daily cleaning of the reference device;
- it follows IEC 61724-1, Annex C;
- soiling ratio from 0 to 100%, declared uncertainty of ≤1% and irradiance from 0 to 1600 W/m²;
- RS485 output with Modbus RTU, up to 38,400 baud, and an output rate of 1 reading per second; the Modbus register map in the catalogue includes instantaneous and daily average ratio, soiling level in percent, daily soiling rate and the wash tank status (full or empty), which makes the quality control described above easier;
- each sensor is calibrated in a class AAA solar simulator according to IEC 60904-2, with a reference cell calibrated by ISFH (Germany), and tested under natural sunlight with a reference cell calibrated by Fraunhofer ISE, according to the manufacturer;
- IP65 protection, 1000 V galvanic isolation between power supply and the RS485 bus and a 3 m UV-resistant cable;
- 18-litre tank, declared consumption of 36 litres per year (two refills per year) and about 100 mL per cleaning cycle; below 0 °C, the manufacturer specifies a mixture of 65% pure water and 35% antifreeze, a rare condition in most of Brazil.
Some information differs between the website product page and the manufacturer's catalogue, and it is worth confirming it when requesting a quote. The product page states 220 VAC power, with a 24 VDC option, while the catalogue gives 100–240 VAC or 24 VDC; the product page gives operation from −40 to +85 °C, while the catalogue assigns that range to the manually cleaned version and gives −20 to +85 °C for the automatic version; the maximum water line is 20 m on the product page and 25 m in the catalogue; and the product page mentions a tank autonomy of 400 days, a figure that does not match the 36 L/year consumption declared on the same page. To plan field visits, take the more conservative value: refill roughly every six months, and monitor the tank status register.
For the researcher, the strong point is the daily automatic cleaning of the reference device, which eliminates the main source of soiling underestimation in long campaigns, and the digital output with ratio and rate already calculated. The limitation, common to every cell-cell sensor, is representativeness: it does not capture the non-uniform soiling of a whole module. In studies that need the actual power loss, combine it with I-V curve measurement of a module in the array.
Alternatives and complements in the catalogue
- Soiling monitoring system for solar panels (ref. HS210-03): indicates surface cleanliness from 100% to 0%, with RS485 Modbus RTU output, measurement once per minute, 12 to 24 V supply, operation from −40 to +70 °C and IP65; the product page gives an accuracy of ±0.1 of reading ±1% after local dust calibration, typical of sensors that require adjustment to local dust. Useful as a second measurement point in another part of the plant.
- PV module measurement system (ref. RDE300i): measures the in-situ I-V curve of a module in the array (up to 30 A, 250 V and 1500 W), with a class A Pt1000 sensor for the back of the module, Modbus RTU and declared compliance with IEC 61724-1 Class A. It makes it possible to calculate soiling from power and capture non-uniform soiling.
- Class A pyranometer with quartz diffuser (ref. MS-80, EKO): secondary standard under ISO 9060:2018, with ventilation and heating options and versions with 4–20 mA or Modbus output. Plane-of-array irradiance reference for the performance ratio.
- Pyranometer for small-scale photovoltaic monitoring (ref. LPPYRA-Lite, Delta OHM): spectrally flat class C thermopile under ISO 9060:2018, 0 to 2000 W/m², passive or 4–20 mA version, IP67. An economical alternative for distributed generation systems and teaching test benches.
- Particulate matter transmitter (ref. PMsense, Delta OHM): PM1, PM2.5 and PM10 by laser scattering, 0 to 1000 µg/m³, RS485 Modbus RTU. Helps relate the soiling rate to dust and smoke episodes.
- Tipping bucket rain gauge (ref. HD2013, Delta OHM): 400 cm² collecting area, made of corrosion-resistant materials, with optional analogue or SDI-12 outputs. Provides the total and intensity of each event to estimate the rainfall threshold that cleans the modules.
To go deeper into each supporting measurement, see also our guides on the pyranometer in the weather station, the tipping bucket rain gauge, air temperature and humidity with a radiation shield, particulate matter and weather station telemetry.
Checklist before requesting a quote
- What is the question: energy loss of a plant, cleaning decision, comparison of coatings or environmental modelling?
- Is the short-circuit current ratio enough, or is the power loss needed because of non-uniform soiling?
- How many measurement points does the area require and where are the dust sources?
- Will the sensor be in the same plane as the array? Is there a tracker?
- Is there water, power and access to refill the tank? What will the visit interval be?
- Which weather station variables will be measured alongside: rain, temperature and humidity, wind, plane-of-array irradiance, particulate matter?
- Which data logger and which protocol (Modbus RTU, SDI-12, analogue) will integrate everything, and with what telemetry?
- Will the campaign cover at least one full year, with dry and rainy seasons?
References
- IEC 61724-1:2021. Photovoltaic system performance – Part 1: Monitoring. Geneva: International Electrotechnical Commission, 2021 (Annex C: soiling measurement using a clean and soiled reference device pair).
- IEC 60891. Photovoltaic devices – Procedures for temperature and irradiance corrections to measured I-V characteristics. Geneva: IEC.
- IEC 60904-2. Photovoltaic devices – Part 2: Requirements for photovoltaic reference devices. Geneva: IEC.
- Schill, C.; Anderson, A.; Baldus-Jeursen, C.; Burnham, L.; Micheli, L.; Parlevliet, D.; Pilat, E.; Stridh, B.; Urrejola, E. Soiling Losses – Impact on the Performance of Photovoltaic Power Plants. Report IEA-PVPS T13-21:2022. International Energy Agency, 2022.
- Costa, S. C. S.; Kazmerski, L. L.; Diniz, A. S. A. C. Impact of soiling on Si and CdTe PV modules: case study in different Brazil climate zones. Energy Conversion and Management: X, v. 10, 100084, 2021. DOI: 10.1016/j.ecmx.2021.100084.
- Costa, S. C. S.; Diniz, A. S. A. C.; Camatta, V.; Kazmerski, L. L. Determinação das taxas de sujidade para módulos fotovoltaicos de filme fino e silício cristalino instalados em diferentes zonas climáticas brasileiras. Revista Brasileira de Energia Solar.
- Souza, T. L. S.; Lima, R. L. F. A.; Lima Júnior, C. Dirt on photovoltaic modules and efficient energy generation in the Brazilian semiarid. Revista Brasileira de Engenharia Agrícola e Ambiental, v. 26, n. 5, p. 321–326, 2022. DOI: 10.1590/1807-1929/agriambi.v26n5p321-326.
- Costa, S. C. S.; Diniz, A. S. A. C.; Kazmerski, L. L. Dust and soiling issues and impacts relating to solar energy systems: literature review update for 2012–2015. Renewable and Sustainable Energy Reviews, v. 63, p. 33–61, 2016.
- Kimber, A.; Mitchell, L.; Nogradi, S.; Wenger, H. The effect of soiling on large grid-connected photovoltaic systems in California and the Southwest region of the United States. IEEE 4th World Conference on Photovoltaic Energy Conversion, 2006.
- Deceglie, M. G.; Micheli, L.; Muller, M. Quantifying soiling loss directly from PV yield. IEEE Journal of Photovoltaics, v. 8, n. 2, p. 547–551, 2018.
- Jones, R. K.; Baras, A.; Saeeri, A. A. et al. Optimized cleaning cost and schedule based on observed soiling conditions for photovoltaic plants in central Saudi Arabia. IEEE Journal of Photovoltaics, v. 6, n. 3, p. 730–738, 2016.
- Ilse, K. et al. Techno-economic assessment of soiling losses and mitigation strategies for solar power generation. Joule, v. 3, n. 10, p. 2303–2321, 2019.
- Seven Sensor Solutions. Solar sensors catalogue (technical sheet of the 3S-SMS-MB soiling sensor and Modbus register map).
Instruments for this application

Seven Sensor3S-SMS-MB
3S-SMS-MB Automatic Soiling Sensor for Photovoltaic Panels

HenSistemasHS210-03
HS210-03 Soiling Monitoring System for Solar Panels

DeltaOhm - GHM GroupLPPYRA-Lite
LPPYRA-Lite Pyranometer for Small-Scale Photovoltaic Monitoring

DeltaOhm - GHM GroupPMsense
PMsense – Particulate Matter Transmitter

DeltaOhm - GHM GroupHD2013