Meteorology · Technical guides
Urban heat island and microclimate research: how to build a network of mini temperature and humidity loggers and validate it with a weather station
A teaching guide to urban heat island and microclimate studies using dense networks of mini temperature and humidity loggers: surface vs atmospheric UHI, what the logger datasheet means for study design (high resolution, memory autonomy, ±5 %RH), solar radiation bias and multi-plate shields, site selection with Local Climate Zones and WMO urban guidance, before-and-after intercalibration, temperature and saturation-drift compensation of humidity with a worked example, validation and synoptic classification with the weather station, field workflow and studies from Curitiba, Cuiabá and Aracaju.

In almost every graduate program in geography, architecture and urbanism, environmental engineering, ecology or forest science at a Brazilian public university, someone is measuring the urban heat island or the effect of parks, street trees and forest fragments on air temperature. And the design is almost always the same: dozens of points scattered across the city, each with a small temperature and humidity logger, and a weather station serving as the reference.
It is a good design. The problem is that errors are multiplied by dozens too. A logger without a proper shield, a humidity sensor that spent the night saturated, or a memory that filled up in the third week can produce a “heat island” that is really an instrumentation artifact.
This guide is for professors, graduate students and technicians who want to plan, install, correct and validate a dense network of mini temperature and humidity loggers for urban climate and microclimate studies. We have already covered air temperature and humidity at the weather station and how to choose a data logger. The angle here is different: what changes when you replace one station with fifty low-cost points.
Heat island: what exactly is being measured
The urban heat island (UHI) is the temperature difference between the urban area and its less urbanized surroundings. The literature describes at least two different phenomena:
- Surface UHI: temperature of surfaces (asphalt, roofs, soil), usually obtained from thermal-infrared satellite imagery (for example, Landsat 8, overpassing at around 10:00–10:30 local time).
- Canopy-layer atmospheric UHI: temperature of the air between the ground and mean roof height, measured by shielded sensors at 1.5–3 m. This is the one that matters for thermal comfort, health and energy demand — and it is the one a logger network measures.
The two are not equivalent. Surface temperature differences are usually much larger than air temperature differences at the same moment, and the atmospheric UHI tends to be strongest at night, when the city releases the heat stored in concrete and asphalt. That is why an air-temperature network must log 24 hours a day, not just at satellite overpass time.
UHI intensity is normally expressed as ΔT(u−r) = T(urban) − T(rural or reference), computed for the same instant. Recent Brazilian studies show it is highly variable: in Aracaju, for example, a mesoscale network found a mean intensity of about 0.5 °C, with more than 85% of differences below 2 °C. In other words, the signal you are looking for may be of the same order of magnitude as your instrument error. That is the central point of planning.
The instrument: button-type mini loggers
iButton-type standalone loggers are coin-sized stainless-steel capsules containing a sensor, clock, battery and memory. For air studies, the most widely used option is the Hygrochron temperature and humidity logger (ref. DS1923-F5). The numbers that matter for planning, according to the product page and the manufacturer’s (Analog Devices) datasheet:
| Parameter | Value |
|---|---|
| Operating range | −20 to +85 °C; 0 to 100 %RH |
| Temperature accuracy | better than ±0.5 °C from −10 to +65 °C, with software correction |
| Temperature resolution | 0.5 °C (8-bit) or 0.0625 °C (11-bit) |
| Humidity accuracy | ±5 %RH, with software correction |
| Humidity resolution | 0.6 %RH (8-bit) or 0.04 %RH (12-bit) |
| RH hysteresis / repeatability | 0.5 %RH / ±0.5 %RH |
| RH stability at 50 %RH | < 1 %RH per year |
| Logging memory | 8 KB, in 8- or 16-bit format |
| Sampling interval | 1 s to 273 h |
| Sealing | initial IP56; 1.27 mm hole in the lid lets air reach the RH sensor |
Three details in the table change the experimental design:
- 8-bit resolution is not suitable for UHI work. With 0.5 °C steps, a ΔT of 0.8 °C becomes quantization noise. Always program high resolution (11-bit for temperature).
- High resolution uses twice the memory. If you log temperature and humidity at 16 bits, the 8 KB memory holds roughly 2,048 readings per channel. At 15 min that is ~21 days of autonomy; at 30 min, ~42 days. Do the math before going to the field — and put the collection date on the group calendar.
- ±5 %RH is the humidity accuracy. For temperature, the logger is very good; for humidity, it is adequate for comparing points with each other, but not for claiming 2–3 %RH differences between neighborhoods without intercalibration.
If the study is temperature-only, the Thermochron temperature logger (ref. DS1922L) is simpler and devotes the whole memory to one channel.
The error that sinks most papers: solar radiation
A temperature sensor measures its own temperature. In the sun, the metal capsule absorbs radiation and warms above the air. Terando and colleagues (2017) showed in Ecology and Evolution that improvised logger mounts in ecological studies — unshielded or with homemade shields — produce biases of several degrees during sunny hours, large enough to reverse conclusions. Hubbart and colleagues (2005) had already shown that the same type of logger, inside an appropriate radiation shield, delivers data comparable to conventional sensors.
The rule is simple: without a ventilated radiation shield, there is no daytime air temperature data. Options:
- Multi-plate shield (stacked white plates, naturally ventilated by wind): the standard for automatic weather stations. The multi-plate radiation shield (ref. EIC2895-01), made of ABS with 4 to 20 plates, accepts the logger fixed inside with a simple bracket.
- Alternative shields (PVC tubes, plastic plates, 3D-printed parts): they can work, but must be compared side by side with the reference shield before joining the network. A mobile-transect study in Cuiabá compared five shields and found that, for nighttime measurements, all alternatives were effective, but only one design (horizontal PVC) performed favorably in every scenario.
Practical care with shields:
- All points must use the same type of shield, the same color and the same sensor position inside it. Shield differences become “UHI” differences.
- The sensor must not touch the shield walls.
- Wash the shields every campaign: urban dust and soot darken the plastic and increase heating.
- If the study is nocturnal (UHI maximum), the shield is still needed because of rain and radiative loss to the sky.
Where to install: representativeness before quantity
Fifty poorly chosen points are worth less than fifteen well-documented ones. Two references guide the choice:
- Oke (2004), WMO guidance for urban observations (IOM Report No. 81): define the scale to be represented (microscale of a street or local scale of a neighborhood), install the sensor away from point heat sources (exhausts, air-conditioning units, sunlit walls) and document the surroundings.
- Local Climate Zones (LCZ), by Stewart and Oke (2012): classify the surroundings of each point into 17 types (compact high-rise, open low-rise, dense trees, bare soil, etc.). Using LCZs lets another group compare your results with those from another city — something “downtown point” and “outskirts point” do not.
Installation recommendations:
- Height: 1.5 to 3 m, the same at every point. Poles and traffic signs are practical supports; the Curitiba study (Leal, Biondi and Batista, 2014) used mini shields attached to traffic-light poles and signs at 44 points, logging every 15 min.
- Clearance: at least 1 m from walls, away from exhausts and dark-painted surfaces; avoid the side of the pole facing the sunniest façade.
- Reference point: the “rural” point must be chosen with the same care. Ideally it is the campus or experimental farm weather station (ref. 6162C), installed over grass according to WMO. We have discussed how to install and validate that station.
- Metadata: photos in four directions, coordinates, height, type of support, LCZ, sky view factor if possible, and the date of each visit. No metadata, no paper.
- Security: small loggers draw little attention, but shields do. A label with the university name and lab contact reduces losses.
Intercalibration: the step that separates signal from noise
Before going out on the street, place all loggers together, in the same shield or in identical shields side by side next to the reference station, for 3 to 7 days, logging at the same interval and on the same clock.
For each logger i, compute:
- Mean bias: b(i) = mean[T(i) − T(ref)]
- Standard deviation of the difference: s(i)
Example: in a 5-day intercalibration of 20 loggers, the temperature bias ranged from −0.3 to +0.4 °C. Without correction, two points in the same air could show a 0.7 °C “island”. Subtracting b(i) from each series brings the residual spread down to the order of the sensor’s repeatability. These figures are illustrative; your set will have its own values, which is exactly why intercalibration must be done.
Repeat the intercalibration at the end of the campaign. If the bias of any logger changed by more than 0.2–0.3 °C, treat the series with caution or interpolate the correction over time.
Humidity: corrections the software must apply
The Hygrochron datasheet describes three chained corrections. Check that your software applies them — ExpressThermo software programs and downloads Thermochron and Hygrochron loggers.
- Calibration correction (uses the factory coefficients stored in each unit).
- Temperature compensation: humidity is calibrated at 25 °C; at other temperatures the reading must be corrected, so log temperature and humidity together. In the datasheet’s own example, a reading of 24.4 %RH at 70 °C becomes 30.3 %RH after compensation.
- Saturation drift compensation: every capacitive RH sensor reads high after spending hours above ~70 %RH. The effect is reversible but grows with exposure time. The datasheet gives an empirical equation per hour of exposure; applying it to 8 consecutive hours at ~90 %RH and 20 °C — a typical humid night in southern and southeastern Brazil — the accumulated correction is around 3.5 %RH. That is the size of many contrasts reported in UHI papers.
Two further limits: the manufacturer states that the device survives at least 1,000 condensation/drying cycles but is not guaranteed for extended use in condensing environments; and the sensor must be kept away from solvents and corrosive gases (SO₂, H₂S, chlorine). At points near heavy traffic, inspect the filter at every collection.
An important note: the protective capsule (ref. DS9107) is sealed and is meant for temperature loggers in wet environments; it blocks the air and therefore is not suitable for the humidity logger. For points exposed to splashing, use the resin-coated temperature version that is water-resistant to IPX8 (ref. HS1922L), and keep humidity for sheltered points.
Validation with the weather station
The weather station is what turns a logger network into a publishable dataset. It serves as:
- Calibration reference (intercalibration before and after).
- Reference series to compute ΔT(u−r) and the difference in absolute humidity (better than RH, which depends on temperature).
- Classifier of synoptic conditions: the UHI peaks on clear, calm nights and almost vanishes with cloud cover and strong wind. With wind, radiation and rain from the station, you separate “ideal” days from cold-front days — an analysis reviewers often ask for.
- Quality control: a logger that suddenly departs from the station (a step change) indicates a sensor touching the shield, a displaced shield or a new heat source nearby.
A simple statistical recommendation: report ΔT by hour of day (mean diurnal cycle) and by condition class (clear/calm × other), with the number of days in each class. Converting RH to absolute humidity or vapor pressure before comparing points avoids confusing “warmer” with “drier”.
Field workflow
- Programming: all loggers on the same interval (10–15 min), synchronized start at a round time, computer clock set correctly. The starter kit with reader (ref. EIC-DS9092K) provides the interface to the computer.
- Time stamping: use the same time zone across the network and the station; note whether series are in local time or UTC.
- Initial intercalibration (3–7 days).
- Installation with complete metadata.
- Collections before memory fills, with a visual check of the shield.
- Final intercalibration.
- Processing: bias correction, RH compensations, synchronization with the station, gap flagging.
If the project needs real-time data — heat-wave alerts, a public dashboard, a campaign with civil defense — the alternative is a wireless network. The wireless temperature and relative humidity sensor (ref. Aranet-TDSPT001) has 0.4 °C and 4 %RH accuracy (0–80 %RH at 30 °C), up to 3 km line-of-sight range and transmits to a base station. It costs more per point but eliminates collection trips. We discussed communication options in weather station telemetry.
How to choose
| Situation | Best choice |
|---|---|
| Nocturnal UHI, temperature only, many points, limited budget | button-type temperature logger, high resolution, in a multi-plate shield |
| Thermal comfort or green-space effects on temperature and humidity | temperature and humidity logger, with compensations applied |
| Wet environments, splashing, water or shallow-soil monitoring | IPX8 resin-coated temperature logger or sealed capsule |
| Real-time data and alerts | wireless sensor network with base station |
| Reference for the whole network | complete weather station installed according to WMO |
Related products
- Hygrochron temperature and humidity logger (ref. DS1923-F5): the main instrument in this guide.
- Thermochron temperature logger (ref. DS1922L): when only temperature matters.
- IPX8 water-resistant temperature logger (ref. HS1922L): points exposed to water.
- Protective capsule for temperature loggers (ref. DS9107).
- Starter kit with reader for button-type loggers (ref. EIC-DS9092K).
- ExpressThermo software: programming, download and data management.
- Multi-plate radiation shield (ref. EIC2895-01): a standardized shield for every point.
- Wireless temperature and relative humidity sensor (ref. Aranet-TDSPT001): real-time network.
- Davis Vantage Pro2 Plus cabled weather station (ref. 6162C): network reference.
Checklist before using the data in your thesis
- Were all loggers at high resolution and on the same interval?
- Was memory autonomy calculated, and did collections happen before it filled?
- Do all points use the same shield, at the same height?
- Was there intercalibration before and after, and was each unit’s bias removed?
- Were temperature and saturation compensations applied to humidity?
- Was humidity compared as absolute humidity or vapor pressure?
- Does each point have metadata (photos, LCZ, height, support, nearby heat sources)?
- Do the analyses separate clear, calm nights from other conditions, using the reference station?
References
- Analog Devices. DS1923 — Hygrochron Temperature/Humidity Logger iButton with 8KB Datalog Memory. Datasheet.
- Hensistemas product page: Hygrochron temperature and humidity logger (ref. DS1923-F5).
- Hubbart, J.; Link, T.; Campbell, C.; Cobos, D. Evaluation of a low-cost temperature measurement system for environmental applications. Hydrological Processes, 19(7), 1517–1523, 2005. DOI: 10.1002/hyp.5861.
- Terando, A. J.; Youngsteadt, E.; Meineke, E. K.; Prado, S. G. Ad hoc instrumentation methods in ecological studies produce highly biased temperature measurements. Ecology and Evolution, 7(23), 9890–9904, 2017. DOI: 10.1002/ece3.3499.
- Stewart, I. D.; Oke, T. R. Local Climate Zones for urban temperature studies. Bulletin of the American Meteorological Society, 93(12), 1879–1900, 2012. DOI: 10.1175/BAMS-D-11-00019.1.
- Oke, T. R. Initial guidance to obtain representative meteorological observations at urban sites. IOM Report No. 81, WMO/TD-No. 1250. Geneva: World Meteorological Organization, 2004.
- Leal, L.; Biondi, D.; Batista, A. C. Influência das florestas urbanas na variação termo-higrométrica da área intraurbana de Curitiba – PR. Ciência Florestal, 24(4), 807–820, 2014. DOI: 10.1590/1980-509820142404002.
- Análise da utilização de abrigos termo-higrométricos alternativos para transectos móveis (Cuiabá-MT), 2020. DOI: 10.6008/CBPC2318-3055.2020.003.0006.
- Rede climatológica de mesoescala aplicada ao estudo da ilha de calor urbano: o caso de Aracaju-SE. Revista Caminhos de Geografia. DOI: 10.14393/RCG1837003.
Instruments for this application

Maxim IntegratedDS1923-F5
DS1923-F5 Hygrochron Temperature/Humidity Logger

Maxim IntegratedDS1922L
DS1922L Thermochron iButton Temperature Data Logger, -40°C to +85°C

Maxim IntegratedHS1922L
HS1922L iButton Temperature Logger, Water-Resistant to IPX8

Maxim IntegratedDS9107
DS9107 iButton Capsule for Temperature Logger iButtons

Maxim IntegratedEIC-DS9092K
EIC-DS9092K Starter Kit for iButtons

EIC2895-01
Multi-Plate Radiation Shield

AranetAranet-TDSPT001
Aranet-TDSPT001 Wireless Temperature and Relative Humidity Sensor

Davis Instruments6162C



