Meteorology · Agriculture · Technical guides
Canopy temperature with an infrared sensor in research: water stress, the CWSI and pairing with the weather station
A teaching guide to infrared canopy thermometry in research: why leaves warm up under water deficit, how the infrared sensor measures, field of view and distance-to-target ratio, emissivity correction using sky temperature, computing the crop water stress index (CWSI) with empirical and theoretical methods, accuracy and cross-calibration, installation, quality control and pairing with air temperature, humidity, radiation and wind from the weather station.

A well-irrigated plant transpires, and the water that evaporates through the stomata cools the leaves, in the same way that sweat cools the skin. When the soil lacks water, the stomata close, transpiration drops, and the leaf heats up. This difference of a few degrees between the leaf and the air is one of the fastest signals of water stress, and it appears before any visible symptom such as wilting or leaf rolling.
Measuring this temperature without touching the leaf is what an infrared surface temperature sensor does (also called an infrared radiometer or fixed infrared thermometer). Mounted on a mast and pointed at the canopy, it continuously records the temperature of the vegetation. Combined with air temperature, humidity, solar radiation, and wind from the weather station, this data becomes the crop water stress index (CWSI), a tool used in Brazil and around the world to study physiology, compare genotypes, and schedule irrigation.
This guide is for professors, graduate students, and researchers at universities and public institutes who want to set up this type of measurement. The goal is to explain the physical principle, the field-of-view geometry, the emissivity correction, the CWSI calculation, and the installation and analysis precautions that make the difference between publishable data and a misleading graph.
Why the leaf heats up when water is scarce
The leaf receives energy from the sun and the atmosphere and needs to get rid of it. It does this through three pathways: emitting infrared radiation, exchanging sensible heat with the air, and evaporating water (latent heat). In a plant with an adequate water supply, transpiration consumes a large share of the available energy and keeps the leaf close to air temperature, or even below it on dry days.
When the soil dries out, the plant partially closes its stomata to conserve water. With less transpiration, more energy is left over to heat the leaf, and the difference between canopy temperature (Tc) and air temperature (Ta) increases. This is why the variable of interest is not leaf temperature alone, but the difference Tc − Ta, read together with atmospheric demand.
An important point for anyone interpreting the data: the same Tc − Ta difference can mean different things depending on the air conditions. On a very dry day, with a high vapor pressure deficit, a plant under no stress transpires heavily and stays much cooler than the air. On a humid, cloudy day, even a well-irrigated plant stays close to air temperature. That is why canopy temperature data only makes sense alongside humidity, radiation, and wind data measured at the same site.
How the infrared sensor measures temperature
Every body above absolute zero emits electromagnetic radiation, and the intensity and distribution of that radiation depend on temperature. At ambient temperatures, most of the emission is in the thermal infrared. The sensor uses a thermopile (a set of thermocouples in series) to measure the radiation arriving from the surface, and a thermistor to measure the temperature of the sensor body itself, which enters the calculation as a reference.
The typical spectral range is 8 to 14 µm, the so-called atmospheric window. In this range, water vapor and CO₂ absorb little, so the radiation leaving the leaf reaches the sensor without significant attenuation over the distances of one to a few meters used in the field.
What the sensor delivers, strictly speaking, is the brightness temperature: the temperature a perfect black body (emissivity 1) would need to have in order to emit the same radiation. For leaves, the difference is small, but it exists, and we will see how to correct for it.
Field of view: what the sensor is actually seeing
The most overlooked specification of an infrared sensor is the distance-to-target ratio (D:T). It indicates the diameter of the area viewed at a given distance. With a D:T of 8:1, for example, a sensor pointed vertically views a circle with a diameter equal to one-eighth of the distance:
- at 1.0 m above the canopy, a circle of about 12.5 cm;
- at 1.5 m, about 19 cm;
- at 2.0 m, about 25 cm.
This target is small. In a row crop with an open canopy, it may capture only leaves, only soil, or a mixture, and the reading changes as the wind sways the plants. Three practical rules help:
- Tilt the sensor. Pointing at about 45° relative to vertical, along or diagonal to the rows, increases the area viewed (which becomes an ellipse) and the fraction of leaves in the target. In Brazilian studies with a handheld thermometer on tomato, for example, readings were taken 1.0 m from the canopy with a tilt of about 45° (Silva et al., 2018).
- Never let the sky enter the field of view. With excessive tilt, the upper edge of the ellipse reaches the horizon, and a clear sky has a very low brightness temperature, which pulls the reading down. Angles that are too wide also cause the viewed area to grow rapidly.
- Preferably point north or south depending on the objective, but consistently, avoiding having the mast itself or the sensor cast a shadow on the target at any time of day.
The problem of exposed soil deserves special attention. Early in the cycle, with little vegetative cover, the sensor measures a weighted average among leaf, soil, and, under no-till, straw/mulch residue. A recent study with common bean showed that, under low canopy cover, straw residue in the field of view distorted the measurement to the point that the baseline became inconsistent with CWSI theory; the authors proposed estimating the cover fraction and the residue temperature with complementary data in order to isolate canopy temperature (Góes et al., 2025). In simple terms:
T_sensor ≈ f_c × T_canopy + (1 − f_c) × T_background
where f_c is the fraction of the field of view occupied by leaves. When f_c is close to 1, the reading is that of the canopy. When it is not, f_c must be estimated (via imaging, leaf area index, or crop height) or the analysis must be restricted to the closed-canopy stage.
Emissivity: the correction almost everyone gets wrong
A leaf is not a perfect black body. The emissivity of a closed canopy is typically between 0.98 and 0.99, and that of soils and dry surfaces is lower. The portion the surface does not emit (1 − ε) it reflects from the surroundings, and in the field the surroundings it "mirrors" are mainly the sky.
The common correction of dividing the measured temperature by emissivity is wrong, because it ignores this reflected radiation. The correct form, with temperatures in kelvin, is:
T_target = [ (T_sensor⁴ − (1 − ε) × T_sky⁴) / ε ]^(1/4)
Two practical consequences:
- On a clear-sky day, the sky is very cold in the infrared, the leaf reflects little energy, and the uncorrected reading comes out below the true value. The error grows as the target's emissivity decreases, so it is larger on exposed soil than on a closed canopy.
- On a cloudy day, the sky's brightness temperature approaches that of the target, and the correction practically disappears. Dividing by emissivity in this case overcorrects.
For emissivities above 0.98, the residual error tends to stay below 1 °C, but in research it is worth recording sky temperature with a second infrared sensor pointed upward or with a pyrgeometer, or at least estimating it from a model based on air temperature and humidity.
The crop water stress index (CWSI)
The CWSI was proposed by Idso and colleagues in 1981 and gained a theoretical basis with Jackson and colleagues the same year. The idea is to normalize the Tc − Ta difference between two limits:
CWSI = [ (Tc − Ta) − (Tc − Ta)_L ] / [ (Tc − Ta)_U − (Tc − Ta)_L ]
- (Tc − Ta)_L, the lower limit or non-stressed baseline: the expected difference for a crop transpiring at its full potential, with water freely available.
- (Tc − Ta)_U, the upper limit: the expected difference for a crop with no transpiration at all (stomata closed).
The index ranges from 0 (no stress) to 1 (maximum stress). There are two ways to obtain the limits.
Empirical method (Idso)
Tc − Ta is measured in a well-irrigated plot, over several days and times near solar noon, together with the vapor pressure deficit (VPD) of the air. The relationship is usually linear with a negative slope: the drier the air, the cooler the leaf relative to the air.
(Tc − Ta)_L = a + b × VPD
The upper limit can be obtained from a non-irrigated plot at peak stress, from a fixed value from the literature for the crop, or from the equation itself, evaluated at the vapor pressure gradient associated with the temperature increase. The method is simple, but the baseline is specific to the crop, the growth stage, and the local climate, and is valid only for clear-sky conditions and times near solar noon.
Theoretical method (Jackson)
This approach starts from the canopy energy balance and uses the station's variables:
(Tc − Ta)_U = r_a × R_n / (ρ × c_p)
(Tc − Ta)_L = [r_a × R_n / (ρ × c_p)] × [γ* / (Δ + γ*)] − VPD / (Δ + γ*)
with γ* = γ × (1 + r_cp / r_a), where r_a is the aerodynamic resistance (calculated from wind speed and crop height), r_cp is the canopy resistance under potential transpiration, R_n is the net radiation, ρ and c_p are the density and specific heat of air, Δ is the slope of the saturation vapor pressure curve, and γ is the psychrometric constant. The terms Δ and γ are the same as in the FAO-56 Penman-Monteith method, explained in our guide on reference evapotranspiration.
The authors showed that, in this formalism, the index is equivalent to 1 − E/Ep, that is, one minus the ratio between actual and potential evapotranspiration calculated by Penman-Monteith. The theoretical method requires more variables, but adapts better to different wind and radiation conditions. In industrial tomato in southern Goiás, irrigated by subsurface drip with five water depths (50 to 150% of crop evapotranspiration), the theoretical and empirical methods estimated the CWSI similarly; even with fairly moist soil, the index exceeded 0.2 during the hottest hours, and the higher the CWSI, the lower the yield (Silva et al., 2018).
Numerical example
An illustrative example, with a hypothetical baseline (do not use these coefficients in your own work):
- Air temperature: 32 °C; relative humidity: 40%.
- Saturation pressure at 32 °C: e_s = 0.6108 × exp(17.27 × 32 / (32 + 237.3)) ≈ 4.76 kPa.
- VPD = 4.76 × (1 − 0.40) ≈ 2.85 kPa.
- Hypothetical baseline: (Tc − Ta)_L = 2.0 − 1.9 × VPD ≈ −3.4 °C.
- Hypothetical upper limit: (Tc − Ta)_U = +4.0 °C.
- Measured canopy temperature: 31.5 °C, so Tc − Ta = −0.5 °C.
CWSI = (−0.5 − (−3.4)) / (4.0 − (−3.4)) ≈ 0.39
Notice how directly the result depends on relative humidity and air temperature: an error of a few points of RH changes the VPD and shifts the baseline. The CWSI is only as good as the weather station accompanying it.
Sensor accuracy and what it means for the CWSI
Robust infrared sensors for continuous outdoor use typically have absolute accuracy on the order of ±1 to ±2 °C, while the difference between a stressed and a non-stressed plant can be 2 to 5 °C. This does not make the work unfeasible, but it calls for method:
- Compare treatments using the same sensor model and intercalibrate the sensors before the experiment, pointing all of them at the same target (a uniform surface or a well-stirred water bath) and recording the offset of each one. Systematic offsets are correctable; what matters for comparing treatments is repeatability.
- Check against a reference periodically, for example with a contact thermometer on representative leaves or with a higher-accuracy reference sensor.
- Use resolution and response time to your advantage: with a resolution of 0.1 °C and a response time of about 1 s, it is possible to take several readings per minute and record 5- to 15-minute averages, which reduces the noise from moving leaves.
- Keep the lens clean. Dust, cobwebs, and soil splashes on the optical window alter the reading. Include cleaning in the site-visit routine.
If the objective requires absolute accuracy better than ±0.5 °C, for example to close the energy balance, the choice should fall on radiometers with traceable calibration and sensor-body compensation, and the budget should plan for this.
Field installation, step by step
- Height and angle. Set the distance to the canopy based on the area you want to view (D:T), and tilt the sensor to increase the fraction of leaves, without including sky. Reassess the height as the crop grows; an adjustable mount makes this easier.
- Orientation. Keep the same orientation across all plots, so that the effect of the sun (sunlit or shaded leaves) is comparable between treatments.
- Replicates. At least one sensor per plot, and more than one when spatial variability is large. Install at least one well-irrigated reference plot for the baseline.
- Timing. The CWSI is most reliable from late morning to early afternoon, near solar noon, under clear sky. Record throughout the day, but perform the main analysis within that window.
- Station alongside. Air temperature and humidity in a radiation shield, 1.5 to 2 m above the ground or at a fixed height above the canopy; global solar radiation; wind speed; and, if possible, net radiation and sky temperature. See our guide on air temperature and humidity at the station.
- Soil moisture for validation. Soil moisture probes in the root zone allow checking whether the CWSI tracks available water, and help separate water stress from other factors (disease, salinity, compaction). See the guide on soil moisture with TDR.
- Data logger and protocol. Confirm the interface: many field infrared sensors use RS485 with Modbus, while part of the weather sensors use SDI-12 or analog signals. Choose a data logger that accepts all the interfaces in your set, and synchronize the clock. See how to choose a data logger.
- Power and cabling. Calculate the consumption of all sensors and the data logger to size the battery and solar panel, and protect the cables from rodents and machinery.
Quality control and data analysis
- Filter by radiation and cloudiness. Use the station's global solar radiation to isolate clear-sky periods. Under passing clouds, Tc oscillates faster than Ta, and the CWSI becomes unstable.
- Discard periods of wet leaf. After rain, sprinkler irrigation, or dew, the evaporation of free water cools the leaf independently of transpiration.
- Track canopy cover. Record periodic photos of each sensor's target to estimate the canopy fraction and detect soil or straw/mulch residue in the field of view.
- Cross-check with wind. Strong winds bring Tc closer to Ta and reduce the index's sensitivity; the theoretical method incorporates this through aerodynamic resistance.
- Update the baseline. It changes with the phenological stage and with senescence. Fit one baseline per stage, or document the validity period of the one you use.
- Validate physiologically. Whenever possible, compare the CWSI with leaf water potential, stomatal conductance, or soil moisture on selected dates. In the literature, the CWSI correlates well with stem water potential and with leaf conductance.
Other applications of the same sensor
The principle is the same for other surfaces, and a fixed infrared sensor has a place in several research lines:
- Soil surface temperature, complementing buried profile sensors (see the guide on soil temperature) and soil heat flux.
- Urban surfaces and pavements, in studies of heat islands, thermal comfort, and road weather, including assessing the risk of dew or ice formation on roads and bridges in high-altitude regions.
- Pastures and turf, for irrigation management of sports fields and experimental areas.
- Energy balance, where surface temperature enters the calculation of emitted longwave radiation.
Featured product
The infrared surface temperature sensor for continuous outdoor use (ref. HS14IRS2E) was designed for 24-hour monitoring in outdoor environments and lists among its applications the temperature of pavements, bridges, plant canopy, and soil and turf surfaces. According to the product datasheet:
- thermopile with compensation thermistor, in a compact aluminum enclosure, with an adjustable mounting bracket at 90°;
- spectral range of 8 to 14 µm, the atmospheric window described above;
- measurement range of −40 to +70 °C, resolution of 0.1 °C, and response time of 1 s;
- accuracy of ±1% or ±2 °C;
- distance-to-target ratio of 8:1;
- RS485 output with Modbus protocol, power supply of 7 to 15 V DC and consumption of about 5 mA at 12 V DC, which facilitates operation with a solar panel;
- operating environment of −38 to +70 °C and 0 to 100% relative humidity.
For the researcher, the strong points are low consumption, digital output (which avoids analog conversion and reduces noise over long cables), and field-grade construction. The point to plan for is absolute accuracy: for CWSI, follow the intercalibration and verification routine described above, and use sensors of the same model for each treatment. It is also worth including cable length and the mast mount in the quote request.
Catalog alternatives and complements
- Relative humidity and air temperature sensor with SDI-12 output (ref. SRH1A): accuracy of ±1.8% RH (at 25 °C) and ±0.2 °C, for installation with a radiation shield. Provides Ta and the VPD, the two variables that weigh most heavily on the CWSI.
- Spectrally flat class B pyranometer (ref. LPPYRA02, Delta OHM): global solar radiation per ISO 9060:2018, with Modbus RS485 and SDI-12 output versions. Used to filter clear-sky periods and feeds into the theoretical method.
- Two-axis ultrasonic anemometer (ref. HD52.3D, Delta OHM): wind speed and direction with no moving parts, with Modbus RTU and SDI-12 outputs, for the aerodynamic resistance in the theoretical method. See the guide on wind measurement.
- TDR soil moisture sensor with SDI-12 interface (ref. TDR-315H, Acclima): volumetric moisture, permittivity, electrical conductivity, and soil temperature, to validate the CWSI against the water available in the root zone.
- Data logger with 4G module for weather station (ref. HD33MT.4, Delta OHM): RS485 port with Modbus-RTU, SDI-12 port, analog and counter inputs, and transmission over the mobile network. Combines the infrared sensor (Modbus) and the SDI-12 sensors in a single device.
- Housing with acquisition system for weather stations (ref. HD32.35, Delta OHM): data logger in an enclosure for assembling the experiment's reference station. Confirm in the quote the interfaces required for the infrared sensor.
For further reading, see also our guide on the pyranometer and solar radiation.
Checklist before budgeting
- What is the question: comparing genotypes, scheduling irrigation, studying physiology, or closing the energy balance?
- What is the crop and canopy architecture, and at what stage will cover be sufficient for the sensor to see only leaves?
- What is the installation height and angle, and what area will the sensor view with the chosen D:T ratio?
- How many sensors per treatment, and where will the well-irrigated reference plot be located?
- Will the station have air temperature and humidity, radiation, wind, and, if possible, sky temperature at the same site?
- Will there be soil moisture probes for validation?
- Does the data logger accept Modbus RS485 and SDI-12 at the same time, and how will the data be transmitted?
- How will intercalibration of the sensors, lens cleaning, and baseline updates be carried out?
References
- Idso, S. B.; Jackson, R. D.; Pinter Jr., P. J.; Reginato, R. J.; Hatfield, J. L. Normalizing the stress-degree-day parameter for environmental variability. Agricultural Meteorology, v. 24, p. 45–55, 1981.
- Jackson, R. D.; Idso, S. B.; Reginato, R. J.; Pinter, P. J. Canopy temperature as a crop water stress indicator. Water Resources Research, v. 17, n. 4, p. 1133–1138, 1981.
- Silva, C. J.; Silva, C. A.; Freitas, C. A.; Golynski, A.; Silva, L. F. M.; Frizzone, J. A. Tomato water stress index as a function of irrigation depths. Revista Brasileira de Engenharia Agrícola e Ambiental, v. 22, n. 2, p. 95–100, 2018. DOI: 10.1590/1807-1929/agriambi.v22n2p95-100.
- Góes, J. A.; Prado, D. F. S.; Pires, R. C. M.; Chiorato, A. F.; Silveira, J. M. C. Crop water stress index of beans. Bragantia, v. 84, e20240235, 2025. DOI: 10.1590/1678-4499.20240235.
- Campbell, G. S.; Norman, J. M. An Introduction to Environmental Biophysics. 2nd ed. New York: Springer, 1998.
- Apogee Instruments. A review of the physics for emissivity correction of infrared temperature measurements (technical note).
- Allen, R. G.; Pereira, L. S.; Raes, D.; Smith, M. Crop evapotranspiration: guidelines for computing crop water requirements. FAO Irrigation and Drainage Paper 56. Rome: FAO, 1998.
Instruments for this application

HenSistemasHS14IRS2E
HS14IRS2E Infrared Road Temperature Sensor

DeltaOhm - GHM GroupLPPYRA02
LPPYRA02 Series Spectrally Flat Class B (First Class) Pyranometer

DeltaOhm - GHM GroupHD52.3D
HD52.3D Series – 2-Axis Ultrasonic Anemometer

ACCLIMATDR-315H
TDR-315H Soil Moisture Sensor with SDI-12 Interface

DeltaOhm - GHM GroupHD33MT.4
HD33MT.4 Data Logger for Weather Station

DeltaOhm - GHM GroupHD32.35