Meteorology · Agriculture · Technical guides
Soil temperature at the weather station: how to measure the depth profile and use the thermal wave in research
A teaching guide to soil temperature in research: the physics of the thermal wave and damping depth, WMO standard depths, accuracy requirements, trench or profile probe installation, estimating thermal diffusivity, soil heat flux and FAO-56, Brazilian studies on crop residue and no-till, and quality control.

Anyone who measures only the air above the ground sees half of an experiment's thermal story. Seeds germinate, roots take up water and nutrients, microorganisms respire and organic matter decomposes in an environment whose temperature follows its own rules: the surface heats and cools far more than the air, and that oscillation is damped and delayed as it moves down the profile. A few decimetres below the surface, the daily cycle has almost vanished; at one metre, little more than the annual cycle remains. Measuring this thermal wave at several depths is what turns a buried thermometer into a research instrument.
This guide is for lecturers, graduate students and researchers at public universities and institutes working in agrometeorology, soil physics, crop management, ecology and energy balance. We explain why soil temperature varies the way it does, which depths the World Meteorological Organization (WMO) recommends, how to install sensors without distorting the measurement, how to estimate thermal diffusivity and heat flux from the profile, what Brazilian research has shown about soil cover and how to run quality control on the series.
Why soil temperature matters
Soil temperature controls processes that air temperature only explains indirectly:
- germination and emergence: each species has a temperature range in which it germinates well; cold soil delays emergence and a very hot surface layer can harm seedlings;
- root activity and uptake of water and nutrients, which drops in cold soil;
- microbial activity, nitrogen mineralization, decomposition of crop residue and soil CO₂ emission, which all rise with temperature;
- evaporation of water from the surface layer and the surface energy balance itself, in which soil heat flux (G) is one of the terms;
- dynamics of soil pests and pathogens and the performance of pesticides and inoculants.
The classic Embrapa study of the temperature of a Planosol in Pelotas (Rio Grande do Sul), with ten years of readings from 1957 to 1966 at up to ten depths between 2 and 100 cm, already pointed out that soil temperature affects germination, root function, nutrient uptake, water movement and microbial activity. Today, with automatic data loggers, this profile can be followed every few minutes, for years, with no observer.
The physics of the thermal wave
The soil surface receives solar radiation during the day and loses infrared radiation at night. Heat moves into the profile by conduction, and the soil behaves like a filter: it damps fast oscillations and lets slow ones through.
If the surface temperature oscillates as a sine wave with semi-amplitude A₀ (half the difference between the maximum and the minimum) and the soil is homogeneous, heat conduction theory gives two simple results:
A(z) = A₀ · e^(−z/d)
lag(z) = z / (d · ω)
where z is depth, ω is the angular frequency of the cycle (2π divided by the period) and d is the damping depth:
d = √(2κ / ω)
The parameter κ is the soil's thermal diffusivity (in m²/s), the ratio between thermal conductivity λ and volumetric heat capacity C. At a depth d, the amplitude falls to about 37% (1/e) of the surface amplitude; at 3d, to about 5%.
Worked example with the daily cycle
Take κ = 5 × 10⁻⁷ m²/s, a value within the range measured in Brazilian soils (see the diffusivity section). For the daily cycle, ω = 2π / 86,400 s ≈ 7.27 × 10⁻⁵ s⁻¹, which gives d ≈ 11.7 cm. With a surface semi-amplitude of 10 °C (a 20 °C difference between maximum and minimum, common in bare soil on a clear day):
- at 5 cm, the semi-amplitude drops to about 6.5 °C, and the maximum arrives about 1.6 h after the surface;
- at 10 cm, to about 4.3 °C, with a lag of about 3.3 h;
- at 20 cm, to about 1.8 °C, with a lag of about 6.5 h;
- at 50 cm, to about 0.14 °C, with a lag of about 16 h: the daily oscillation is already smaller than the uncertainty of many sensors, and the maximum occurs in the early morning hours;
- at 100 cm, the daily cycle is negligible.
And the annual cycle
For the annual cycle, the period is 365 times longer and the damping depth grows with the square root: with the same κ, d ≈ 2.2 m. At 1 m, the annual wave still keeps about 64% of the surface amplitude and arrives about 26 days late. That is why readings at 50 and 100 cm are so useful in climatology: they filter out day-to-day noise and reveal the seasonal and long-term trend.
The Pelotas study shows exactly this in real data: at the surface, temperature varies widely from month to month; from about 40 cm down, it tends to stabilize within the month.
The model's limits
The sine-wave model assumes homogeneous soil, constant moisture and a periodic surface. In the field, soil has horizons with different properties, moisture changes after every rain (and κ with it), cloudiness interrupts the sine wave and infiltrating water carries heat by convection. The model remains valuable as a reference: large departures from it point either to an interesting physical process or to an installation problem.
Which depths to measure
The WMO Guide to Instruments and Methods of Observation (WMO-No. 8, Volume I, 2024 edition) sets the standard depths at 5, 10, 20, 50 and 100 cm below the surface, allowing additional depths (for example, 2 cm). When choosing for a project, think about the question:
- germination, emergence and microbiology of the plough layer: 2, 5 and 10 cm, where the daily cycle is strong;
- root zone of annual crops: 10, 20 and 30 to 50 cm;
- diffusivity and heat flux: at least two levels within the layer where the daily cycle is still well measured (for example, 5 and 10 cm, or 10 and 20 cm), with precisely known spacing;
- climatology and long-term trends: 50 and 100 cm, where fast oscillations have already been filtered out.
To keep comparability with networks and the literature, include the standard depths whenever possible, even if the project also needs others.
Accuracy and sampling requirements
In the Volume I requirements table, WMO lists for soil temperature a range of −50 to +50 °C, 0.1 K resolution, a 20 s instrument time constant, 1 min output averaging and an achievable uncertainty of 0.2 K. In research practice:
- platinum sensors (Pt100, Pt1000), thermistors and thermocouples all work well, provided the sensor + logger combination is checked;
- thermocouples are cheap and thin, ideal for many points, but their uncertainty depends on the logger's cold-junction compensation; check the specification of the whole system, not just the sensor;
- in the surface layers, log at least every 10 to 30 minutes to capture the maximum and minimum well; at 50 and 100 cm, hourly intervals are enough;
- all levels should be read at the same instant, with the logger clock synchronized, so that the phase-lag calculation makes sense.
Field installation
Installation determines data quality more than the sensor does. The main points, based on WMO guidance and field practice:
- Representative site. WMO recommends a level plot of bare ground typical of the soil of interest; inside the station enclosure, an area of about 2 m × 2 m of bare ground is reserved for the state of the ground and for soil temperature down to 20 cm, and deeper measurements may be made outside it. In agronomic experiments, the "representative site" is the treated plot itself: measure under the cover you want to study and record what it is.
- Describe the site. Record soil type, cover, slope and its direction. WMO recommends, whenever possible, reporting bulk density, thermal conductivity, moisture at field capacity, water table level (if within 5 m) and soil structure. Without this metadata, the series loses much of its scientific value.
- Horizontal insertion into a trench wall. For electrical sensors, WMO describes installation into an undisturbed vertical soil face exposed by a trench: each sensor is inserted horizontally at the required depth, the cables come out through the trench, and the trench is refilled restoring, as far as possible, the original horizons and drainage. Running the cables horizontally for a few decimetres before they rise reduces heat conduction along the cable to the measuring point.
- Beware of vertical metal tubes. WMO warns that vertical steel tubes are unsuitable for measuring the daily variation of soil temperature, especially in dry soil, because they conduct heat from the surface; soil thermal properties calculated from such measurements can be significantly wrong.
- Profile probes. Probes in plastic tubes, inserted into a vertical hole, are practical and minimally destructive. To measure well, soil contact is essential: use an auger of the diameter recommended by the manufacturer, avoid gaps and air pockets, and let the soil resettle for a few days (or a few rains) before using the data. The top of the probe and any cable exposed to the sun should be shaded or light-coloured so they do not heat the first level.
- Verified depth. Measure the actual depth of each sensor after installation, from the final soil surface, and repeat after settling and after tillage operations. A 1 cm error in the distance between two shallow levels already weighs on the diffusivity estimate.
- Protect the spot. Avoid foot and machine traffic over the site, and mark the area.
Thermal diffusivity from the profile
With two well-measured depths, z₁ and z₂, the profile itself lets you estimate the soil's apparent diffusivity κ. The two simplest methods use the thermal wave relationships:
- amplitude method: κ = ω · (z₂ − z₁)² / [2 · (ln(A₁/A₂))²]
- phase method: κ = (z₂ − z₁)² / (2 · ω · Δt²), where Δt is the lag between the times of the maximum (or minimum) at the two depths.
Example. On a clear day, the semi-amplitude is 4.0 °C at 10 cm and 1.6 °C at 20 cm, and the maximum at 20 cm occurs 3 h 15 min after the maximum at 10 cm. With Δz = 0.10 m:
- amplitude: ln(4.0/1.6) = ln 2.5 ≈ 0.916; κ ≈ 7.27 × 10⁻⁵ × 0.01 / (2 × 0.839) ≈ 4.3 × 10⁻⁷ m²/s;
- phase: Δt = 11,700 s; κ ≈ 0.01 / (2 × 7.27 × 10⁻⁵ × 11,700²) ≈ 5.0 × 10⁻⁷ m²/s.
The two values are close but rarely identical. In Campina Grande (Paraíba), a study using depths from 2 to 100 cm at the weather station concluded that, in the intermediate and deep layers, the amplitude method gave more consistent values, while the phase method was more variable and systematically higher. In the Pantanal of Mato Grosso, Danelichen and co-authors (UFMT) compared the amplitude, logarithmic, arctangent and phase methods between 1 and 15 cm; the methods differed from one another, diffusivity by the amplitude method ranged from about 1.0 to 2.0 × 10⁻⁷ m²/s, and it varied with soil water content. The authors also cite values of 1.5 to 3.3 × 10⁻⁷ m²/s in Campina Grande, 1.45 to 6.74 × 10⁻⁷ m²/s in forest and pasture in the Amazon, and 4.7 to 7.5 × 10⁻⁷ m²/s in Salvador.
Practical lessons: use clear, rain-free days, fit the sine wave (first Fourier harmonic) instead of taking only the raw maximum and minimum, know the distance between sensors to the millimetre and measure soil moisture alongside, because it is the main factor that changes diffusivity.
Soil heat flux and the energy balance
Soil heat flux follows Fourier's law: G = −λ · ∂T/∂z. In energy balance research (for example, next to an eddy covariance tower), G is usually measured with a heat flux plate buried a few centimetres deep, and the temperature profile above the plate is used to add the change in heat stored in that layer:
G(surface) = G(plate) + C · Δz · ΔT/Δt
Example. If the 0 to 8 cm layer warms by an average of 2 °C in one hour in the morning and C = 2.1 MJ/(m³·°C), the storage term is 2.1 × 10⁶ × 0.08 × 2 / 3600 ≈ 93 W/m². Ignoring it underestimates G precisely when it is largest and worsens energy balance closure.
For those calculating reference evapotranspiration, FAO-56 simplifies: on a daily scale, G is small and can be taken as zero; on a monthly scale, G ≈ 0.07 · (T of the following month − T of the previous month), using mean air temperature and an assumed soil heat capacity of 2.1 MJ/(m³·°C); on an hourly scale, G ≈ 0.1 Rn during the day and 0.5 Rn at night. These are approximations for the reference grass. In studies of crops, bare soil or crop residue, measuring the temperature profile gives a much more faithful estimate. See our guide to reference evapotranspiration with FAO-56.
We did not find a stand-alone soil heat flux plate in the website catalogue; if your project needs one, talk to our team to assess integration with the temperature profile.
What Brazilian research has shown about soil cover
One of the most common uses of soil temperature in Brazil is comparing management systems. Two examples:
- No-till versus conventional tillage. Furlani and co-authors (Revista Brasileira de Ciência do Solo, 2008) found lower soil temperature under no-till than under conventional tillage from 8 a.m. to 5 p.m., with the difference growing through the day, from 0.8 °C at 8 a.m. to 4.7 °C at 4 p.m.; chisel tillage was intermediate. The authors link the effect to the amount and distribution of crop residue, which reflects and absorbs part of the incoming radiation.
- Residue rates in maize in an Aw climate. Vieira and co-authors (Científica, 2020), on a dystroferric Red Latosol in Tangará da Serra (Mato Grosso), measured temperature with type K thermocouples at 5–10 and 20–25 cm. At 5–10 cm, the thermal amplitude was 10.6 °C without cover, against 5.2 and 4.7 °C with 4 and 8 t/ha of brachiaria residue; at 20–25 cm, amplitudes were 2.9, 2.0 and 2.2 °C. The 8 t/ha cover reduced maximum soil temperature by up to 2.9 °C, and differences were largest early in the season, before the crop shaded the soil.
Notice how the numbers confirm the physics of the thermal wave: amplitude falls quickly with depth, and cover acts mainly on the surface layer. When designing an experiment of this kind, place sensors at the same depth in every plot, use at least two replicates per treatment and measure soil moisture alongside, because wetter soil has a higher heat capacity and damps the oscillation.
Processing and quality control
A minimum routine for soil temperature series:
- Physical limits. Discard values outside the sensor range and outside the plausible range for the site.
- Consistency between levels. Daily amplitude should decrease with depth and the maximum should be delayed. A deep level with a larger amplitude than the one above indicates an exposed sensor, a cable conducting heat, a wrong depth or swapped channels.
- Jumps and steps. Abrupt changes that do not appear at neighbouring levels are usually electrical faults, moisture in the connector or recalibration.
- Stuck sensors. Identical values for hours in shallow layers are suspect.
- Rain and irrigation. Fast, simultaneous drops at several levels after rain are real (cooler water infiltrating); check against the rain gauge before flagging them as errors.
- Comparison with the air. Daily means at 5 and 10 cm track air temperature with a relatively stable offset for a given cover; progressive departures suggest drift.
- Periodic checks. Compare each sensor with a traceable reference thermometer, in the field or in a bath, at installation and at least once a year, and record the results.
- Metadata. Keep measured depths, installation and maintenance dates, soil type, cover and any intervention on the plot.
Common mistakes
- Burying the sensor vertically with the cable rising straight to the surface, creating a heat path.
- Measuring in disturbed soil without waiting for it to resettle, or after tillage that changed the actual depth.
- Leaving the top of a profile probe or its cable exposed to the sun.
- Using different depths across treatments and then comparing amplitudes.
- Calculating diffusivity on cloudy or rainy days, or with levels so deep that the daily amplitude is already smaller than the uncertainty.
- Not recording soil moisture, which changes thermal properties.
- An unsynchronized logger clock, which compromises the phase-lag calculation.
The profile probe in our catalogue
As an example of measuring several depths from a single hole, the catalogue includes the soil moisture and temperature profile probe (ref. HS28N01-TR3). According to the product sheet:
- it measures soil moisture and temperature at several levels: the model on the sheet measures 3 segments, with a maximum of 5, and 10 cm spacing between measuring points;
- moisture is measured by the dielectric constant principle, with a high-frequency wave of nearly 1 GHz that passes through the PVC tube; the sheet states that the measurement is not affected by salt ions in the soil;
- soil temperature range of −30 to +60 °C, with ±0.5 °C accuracy; moisture from 0 to 100%, with ±5% accuracy;
- RS485 output with Modbus RTU protocol, with a communication range of up to 2000 m according to the sheet;
- 10 to 30 VDC power supply, operation from −40 to +80 °C, PVC plastic tube housing and IP68 protection.
The catalogue image shows the version with five observation points, at 10, 20, 30, 40 and 50 cm, in a 63 mm diameter tube; the sheet describes the three-segment model. Confirm in your quote how many levels and which depths your configuration will have.
For researchers, the advantage is having moisture and temperature at the same point and the same instant, from a single hole, which helps interpret changes in diffusivity and supports cross-checking in quality control. The limits also need to be considered in the design: with ±0.5 °C accuracy, the probe is suitable for following the profile, seasonality and differences between treatments in layers where the daily oscillation is several degrees; to estimate diffusivity from two close levels, or to measure 50 and 100 cm depths, where the daily amplitude is small, consider adding platinum sensors or lower-uncertainty thermocouples checked against a reference. The fixed 10 cm spacing also does not match the WMO 5 cm standard depth exactly.
Alternatives and complements in our catalogue
- Soil moisture sensor with SDI-12 interface (ref. TDR-315H, Acclima): a time-domain reflectometer that measures water content, permittivity, apparent electrical conductivity and mean temperature from −40 to +60 °C; it is inserted horizontally into a trench wall, as WMO recommends for temperature sensors. Useful for building a profile sensor by sensor at exactly the depths the project requires.
- Soil moisture and temperature data logger (ref. EIC-OXLSMT, Xtreem): a Bluetooth wireless logger with a soil sensor that includes temperature; the sheet lists 0.01 °C resolution and typical ±0.1 °C accuracy for temperature, IP67 and a battery life of about two years at 10-minute logging.
- Multi-profile soil moisture recording kit (ref. EIC-OXLMPK, Xtreem): probes with 3 to 5 sensors, lengths from 0.4 to 1.0 m and depths such as 10, 20, 30, 40 and 50 cm, to follow the moisture profile alongside the thermal profile.
- Wireless transmitter for Pt100 sensors (ref. TDSPT106.010, Aranet): accepts any class of Pt100 probe in 2, 3 or 4-wire connection, transmits every 1, 2, 5 or 10 minutes with up to 3 km line-of-sight range and IP68; works only with Aranet base stations. A good option for many points in plots far from a central logger.
- 8-channel handheld thermocouple data logger (ref. EICS220-T8): accepts several thermocouple types, including K and T, with 0.1 °C resolution, 86,000-reading memory and intervals from 2 s to 24 h. It allows a dense profile with thin thermocouples, as in soil cover studies; the stated accuracy of ±1 °C ± 5‰ applies to the system and should be considered in the experimental design.
- Data logger for weather stations (ref. HD33MT.4, Delta OHM): analogue inputs for Pt100, Pt1000 and thermocouples, an RS485 Modbus RTU port (which can read the profile probe), an SDI-12 port and 4G/3G/2G transmission. It integrates the soil profile with the station's other variables.
For more on the supporting measurements, see also our guides on soil moisture, air temperature and humidity with a radiation shield, how to choose a data logger and weather station telemetry.
Checklist before requesting a quote
- What is the question: germination, cover management, energy balance, diffusivity or climatology?
- Which depths are needed, and do they include the WMO standard depths (5, 10, 20, 50 and 100 cm)?
- What uncertainty is acceptable at each level, especially the deeper ones, where amplitude is small?
- Will soil moisture be measured at the same point?
- Will installation be in a trench with horizontal sensors or in a hole with a profile probe?
- How many points and replicates per treatment, and how far from the logger?
- Which logger and protocol (Modbus RTU, SDI-12, analogue, wireless) will integrate everything, at what interval and with what telemetry?
- How will the sensors be checked against a reference, at installation and throughout the project?
References
- World Meteorological Organization. Guide to Instruments and Methods of Observation, Volume I – Measurement of Meteorological Variables (WMO-No. 8). Geneva: WMO, 2024 edition (chapter 1, accuracy requirements and station layout; chapter 2, measurement of soil temperature).
- Allen, R. G.; Pereira, L. S.; Raes, D.; Smith, M. Crop evapotranspiration: guidelines for computing crop water requirements. FAO Irrigation and Drainage Paper 56. Rome: FAO, 1998 (soil heat flux).
- Furlani, C. E. A.; Gamero, C. A.; Levien, R.; Silva, R. P.; Cortez, J. W. Temperatura do solo em função do preparo do solo e do manejo da cobertura de inverno. Revista Brasileira de Ciência do Solo, v. 32, p. 375–380, 2008. DOI: 10.1590/S0100-06832008000100035.
- Vieira, F. F.; Dallacort, R.; Barbieri, J. D.; Dalchiavon, F. C.; Daniel, D. F. Temperatura e umidade do solo em função do uso de cobertura morta no cultivo de milho. Científica, v. 48, n. 3, p. 188–199, 2020. DOI: 10.15361/1984-5529.2020v48n3p188-199.
- Danelichen, V. H. M.; Biudes, M. S.; Souza, M. C.; Machado, N. G.; Curado, L. F. A.; Nogueira, J. S. Soil thermal diffusivity of a Gleyic Solonetz soil estimated by different methods in the Brazilian Pantanal. Open Journal of Soil Science, v. 3, p. 15–22, 2013. DOI: 10.4236/ojss.2013.31003.
- Difusividade térmica do solo de Campina Grande para dois períodos do ano. Revista de Geografia (UFPE).
- Estimativas da difusividade térmica e do fluxo de calor de um solo no Agreste Pernambucano. Revista Brasileira de Geografia Física, 2015. DOI: 10.5935/1984-2295.20150053.
- Temperatura do Planossolo em Pelotas, Rio Grande do Sul. Embrapa (Ainfo repository).
Instruments for this application

HenSistemasHS28N01-TR3
HS28N01-TR3 Soil Moisture and Temperature Profile Probe

ACCLIMATDR-315H
TDR-315H Soil Moisture Sensor with SDI-12 Interface

DataFlow-SystemsEIC-OXLSMT
Soil Moisture and Temperature Data Logger

DataFlow-SystemsEIC-OXLMPK
Xtreem Multi-Profile Soil Moisture Recording Kit

AranetTDSPT106.010
Aranet PT100 Wireless Transmitter/Sensor

DeltaOhm - GHM GroupHD33MT.4



