Meteorology · Agriculture · Technical guides

Dendrometers in research: how to measure stem growth and tree water deficit and combine the data with the weather station

A teaching guide to dendrometry: what stem size changes reveal, dendrometer types, conversion to diameter and basal area, separating growth from water deficit, maximum daily shrinkage, VPD from the weather station, temperature effects, installation, research use in Brazil and quality control.

By HenSistemas · · 21 min read

Automatic band dendrometer with stainless steel tape and built-in data logger mounted on a tree trunk

A tree trunk is not a rigid cylinder that slowly gets thicker. It shrinks in the afternoon, swells again at night, reacts to rain within hours and, only on top of these oscillations, grows. Someone who measures diameter with a tape once a year sees only the net result. Someone who installs a dendrometer logging every 10 or 30 minutes starts to see two different things in the same signal: the irreversible growth of wood and the reversible change caused by water stored in stem tissues. The first matters to forest management and to the carbon balance; the second is a direct indicator of plant water status, useful in ecophysiology, in drought studies and in irrigation management of fruit trees.

This guide is for lecturers, graduate students and researchers at public universities and institutes who are going to instrument trees in permanent plots, experimental plantations, orchards or greenhouses. We explain what a dendrometer actually measures, the sensor types, the arithmetic that turns millimetres of band into diameter and basal area, how to separate growth from water deficit, why temperature gets in the way, how to install, how to combine the data with the weather station and with soil moisture, and how to quality-control the series.

What the trunk is telling you

The diameter change measured over the bark is the sum of at least three processes:

  • Growth (GRO). Cell division and expansion in the cambium, which produces wood (xylem) inwards and living bark (phloem) outwards. It is a one-way process: it only increases the radius.
  • Tree water deficit (TWD). During the day, leaf transpiration removes water faster than roots can replace it. The plant compensates by drawing on water stored in the elastic stem tissues, mainly the living bark, which contracts. At night, with low transpiration, the tissues rehydrate and the trunk swells again. This process goes back and forth.
  • Non-biological effects. Thermal expansion of the wood and of the sensor itself, swelling of dead bark when it gets wet, stem freezing in cold regions and sensor displacement.

The typical result, on a sunny day with moist soil, is a curve with a maximum in the early morning, a decline until mid or late afternoon and recovery during the night. Deslauriers and co-workers formalised this reading by dividing the daily cycle into three phases: contraction (from the morning maximum to the daily minimum), expansion (from the minimum to the next morning maximum) and increment (the part of the expansion that exceeds the previous maximum). When the trunk does not recover the previous day's maximum, there was no increment in that cycle: there was a net water loss.

Types of dendrometer

Diameter tape (manual). A tape graduated in diameter units, read by a person once or twice a year. It is the standard for inventories and permanent plots. Cheap, but its resolution is limited by the operator and it says nothing about the daily cycle.

Manually read dendrometer band. A stainless steel band stays permanently around the trunk, tensioned by a spring, and a scale with a vernier shows how much the circumference has increased since installation. Readings with a vernier or caliper reach a tenth of a millimetre. It is used to follow the growth of hundreds of trees at low cost, with monthly or seasonal visits.

Automatic dendrometer band. The same steel band, now connected to a position sensor and a logger. It measures the whole circumference, which gives a natural average over the entire perimeter, and allows the daily cycle to be recorded with micrometre-level resolution. It is the type most used to monitor mature trees in the field for years.

Point (radial) dendrometer. A displacement transducer (potentiometric or LVDT type) resting on a single point of the trunk, held by a frame anchored in the wood or by a yoke around the stem. It has very high resolution and fast response, which makes it the classic tool for measuring maximum daily shrinkage in irrigation studies. The trade-off is that it measures a single radius and depends heavily on the stability of the frame.

Dendrometers for thin stems. Point or clamp versions for branches, seedlings, vines, greenhouse crops and fruits, with ranges of a few millimetres.

Rule of thumb: if the question is how much the tree has grown over months and years, the band (manual or automatic) is the natural tool; if the question is how the tree responds, hour by hour, to soil water and atmospheric demand, continuous logging is mandatory, and the choice between an automatic band and a point dendrometer depends on stem diameter and the resolution needed.

From band to diameter, radius and basal area

The band measures the change in circumference, ΔC. Since circumference is C = π·D, the conversions are straightforward:

ΔD = ΔC / π

ΔR = ΔC / (2·π)

Forest management and biomass models rely more on basal area, the cross-sectional area of the trunk at 1.30 m above the ground, the diameter at breast height (DBH) convention:

BA = π·D² / 4

and on the basal area increment (BAI) between two dates:

BAI = π·(D₂² − D₁²) / 4 ≈ (π/2)·D·ΔD

Worked example

A tree with a DBH of 30.0 cm (circumference 94.2 cm) receives an automatic band. Over one year, the reading goes from 12.40 mm to 18.40 mm.

  • ΔC = 6.00 mm
  • ΔD = 6.00 / π = 1.91 mm, so the DBH went from 300.0 mm to about 301.9 mm
  • ΔR = 0.95 mm of radius, which corresponds roughly to the width of the growth ring plus the increase in living bark thickness
  • BAI = π·(301.91² − 300.00²) / 4 ≈ 903 mm², or about 9.0 cm² per year

Two teaching points come out of this example. First, the same tree with twice the diameter and the same ΔD would have twice the BAI: this is why comparisons between trees of different sizes use basal area or relative rates, not just millimetres of diameter. Second, if the band has a travel of 64 mm of circumference, it can accommodate about 64 / π ≈ 20 mm of diameter gain. For this tree, that would be a decade; for fast-growing species or young trees in plantations, the travel may run out within a few seasons, and reinstallation must be on the schedule.

Separating growth and water deficit

With the continuous series of radius (or circumference), the central question is: how much of each rise is growth and how much is just rehydration?

The most widely used method today is the zero-growth concept, evaluated by Zweifel and co-workers in 2016. The idea is simple:

  1. track the running maximum of the radius up to each instant;
  2. whenever the reading is below that maximum, the difference is tree water deficit (TWD), and no growth is assumed during that interval;
  3. only when the reading exceeds the previous maximum is the excess counted as growth (GRO).

In compact notation, for each instant t:

max(t) = highest value of R between the start of the series and t

TWD(t) = max(t) − R(t)

GRO(t) = max(t) − max(t₀)

The resulting growth curve is step-shaped: it rises in steps when the trunk is saturated and the tree is growing, and stays flat during dry spells. The authors compared this concept with the alternative of assuming linear growth between two peaks and concluded that, in the species studied, growth during stem shrinkage was very small. They themselves note that definitive validation requires independent growth data, such as anatomical analysis of wood formation.

The second classic indicator is maximum daily shrinkage (MDS):

MDS = R(morning maximum) − R(afternoon minimum)

MDS increases with the evaporative demand of the air and with soil dryness. On its own, therefore, it mixes the two causes. Goldhamer and Fereres solved this for irrigation management of fruit trees by creating an MDS signal: the ratio between the MDS of the managed trees and a reference MDS, obtained from well-irrigated trees and expressed as a function of the day's vapour pressure deficit (VPD). A signal close to 1 indicates no stress; higher values indicate deficit. In the California almond orchard they studied, thresholds of 1.75 and 2.75 produced mild and moderate stress, and irrigation was adjusted by 10% whenever the signal stayed above or below the threshold for three consecutive days. These numbers belong to their experiment and do not transfer directly to another species or climate: the method does.

Calculation example: on a day whose mean VPD, according to the reference-tree regression, corresponds to an expected MDS of 0.20 mm, the treatment tree shrank 0.35 mm. The signal is 0.35 / 0.20 = 1.75.

The weather station is part of the experiment

Because daily shrinkage is driven by transpiration, a dendrometer can only be interpreted alongside a weather station and, ideally, soil moisture sensors. The minimum variables are:

  • air temperature and relative humidity, to compute VPD;
  • solar radiation, which drives stomatal opening and transpiration;
  • rainfall, to explain sudden rehydration and bark swelling;
  • soil moisture at one or more depths in the root zone;
  • if possible, wind, to complete reference evapotranspiration.

VPD comes from temperature (T, in °C) and relative humidity (RH, in %), using the FAO-56 saturation vapour pressure:

eₛ(T) = 0.6108 · exp(17.27·T / (T + 237.3)) (kPa)

VPD = eₛ(T) · (1 − RH/100)

On a hot, dry early afternoon at 32 °C and 40% RH, eₛ = 4.76 kPa and VPD is 2.85 kPa. On a cloudy morning at 18 °C and 90% RH, eₛ = 2.06 kPa and VPD is only 0.21 kPa. A more than tenfold difference in the force pulling water out of the leaf explains why trunk shrinkage varies so much from one day to the next, even with equally moist soil.

For these measurements, see our guides on air temperature and humidity and radiation shields, soil moisture and FAO-56 reference evapotranspiration.

Two design choices help the analysis a great deal:

  1. Same clock and same interval. Dendrometers and the station should log with timestamps in the same time zone (preferably UTC) and at intervals that are multiples of each other, for example 10 or 30 minutes. Otherwise the phase of the daily cycle gets blurred.
  2. Reference trees. In irrigation or drought studies, keep some trees without water restriction to build the relationship between MDS and VPD. This is what turns shrinkage into a stress signal.

Temperature: the error that looks like a signal

The stainless steel band expands with heat. The brochure of the automatic dendrometer in our catalogue gives a band thermal coefficient of 1.6 × 10⁻⁵ per degree. For the tree in the example, with a circumference of 0.942 m, a daily change of 20 °C in band temperature changes its length by:

ΔL = 0.942 m × 1.6 × 10⁻⁵ /°C × 20 °C ≈ 0.30 mm

That is equivalent to about 0.10 mm of diameter, the same order of magnitude as a small daily shrinkage. Wood and bark also expand, and point sensors have the same problem in the frame. The practical consequences:

  • record the temperature next to the sensor (many automatic dendrometers have an internal sensor for this) and use it to correct or, at least, to flag suspicious days;
  • shade the sensor and band from direct sun when possible, or install on the least exposed side;
  • be suspicious of perfect daily cycles on clear days with saturated soil: it may be thermometry, not physiology;
  • in long-term growth studies, thermal expansion matters less, because it cancels out between dates in the same season; in MDS studies, it matters a lot.

Field installation

The guidelines below combine the manufacturers' brochures with the metal band dendrometer protocol of the Smithsonian's ForestGEO network, used in tropical plots.

Choosing the trees.

  • Define the sample from the question: species, diameter classes, canopy position and crown illumination. Record DBH, height, crown condition and illumination at installation.
  • Avoid trunks with dense thorns, rapidly peeling bark, buttresses reaching the measurement height, forks and deformities.

Height and point of measurement.

  • The reference is DBH at 1.30 m; on sloping ground, measure the height from the uphill side.
  • The ForestGEO protocol installs the band about 10 cm above the inventory measurement point, so that it does not interfere with the diameter tape. If there are buttresses, raise the point to about 50 cm above their top.
  • Record the exact height and mark the point with paint.

Bark preparation.

  • Remove moss, lichens, dirt and loose bark in the installation strip. On very rough bark, smooth only the superficial dead part without injuring the living bark: a wound alters precisely the tissue you want to measure.
  • Pass the band under lianas and epiphyte roots, or pull them away. A liana between the band and the trunk becomes an artificial step as it grows.

Mounting.

  • The band must be level, flush with the trunk all the way round and at the tension specified by the manufacturer. Loose bands underestimate growth; bands that are too tight can mark the bark.
  • Secure the cable and logger so that wind and animals do not pull the sensor.
  • For point dendrometers, use a frame made of low-expansion material with firm anchoring in the wood, and shade the assembly.

Settling.

  • Every band needs a period to "settle" on the bark. The ForestGEO protocol notes that bands tend to underestimate growth right after installation and recommends monthly remeasurement of part of the sample during the first 6 to 12 months; the full series becomes reliable 3 to 12 months later, depending on growth rate. Install before the growing season you want to study, preferably during the drier period, and treat the first stretch of the series as settling.

Maintenance.

  • At every visit, check whether the band is still level, whether the spring or travel is close to its end, whether there is a new liana, and whether the sensor has moved; record everything in the field notebook and in the series metadata.
  • When the travel is nearly used up, read the old band, install a new one and document the jump in the series.

Dendrometers in Brazilian research

Continuous dendrometry has a large field in Brazil, precisely because many tropical species do not form clear annual rings and the dendrometer is one of the few ways to see the seasonality of growth in real time. Some examples of application:

  • Tropical forests and carbon. At INPA (National Institute for Amazonian Research), master's theses have followed diameter growth in terra firme forest in Central Amazonia with dendrometer bands, including automatic dendrometers logging hourly at the ZF-2 Experimental Station alongside micrometeorological stations. In the automatic dendrometer network of the AmazonFACE experiment, stem growth increased in the wet season and fell at the onset of the dry season, with a "midday depression" signal in the dry period.
  • Fragmentation and succession. Comparing continuous forests, fragments and secondary forests with the same bands and the same protocol shows how increment responds to forest structure and rainfall.
  • Forest plantations. Eucalyptus, pine, teak and native species in restoration: responses to water deficit, silvicultural treatments, spacing and clones, at daily rather than annual resolution.
  • Irrigated fruit growing and coffee. MDS signal and TWD as indicators of when to irrigate and how much stress to apply in regulated deficit strategies, always calibrated locally against water potential measured with a pressure chamber.
  • Ecophysiology of Cerrado, Caatinga and Atlantic Forest species. When the tree stops growing in the dry season, when it resumes after the first rains, and how deciduous and evergreen species differ.
  • Teaching. A manual band and an automatic band on the same campus tree, next to the weather station, make an excellent practical class on plant water relations.

For networks with many points and remote follow-up, see also our guide on weather station telemetry.

Processing and quality control of the series

Raw dendrometer data have typical defects, and the worst mistake is to compute growth before cleaning them. A minimal workflow:

  1. Align time. Put all series on the same regular interval and time zone, and document any clock adjustment.
  2. Remove isolated spikes. Readings that jump and come back in a single record are usually electrical noise, someone touching the sensor or an animal.
  3. Correct shifts. Re-tightening the band, battery replacement, reinstallation or a fallen branch create permanent steps. They must be identified (preferably with the field notebook) and corrected by adding or subtracting the step, never interpreted as growth.
  4. Flag rain events. Rapid swelling right after rain may be rehydration of dead bark rather than living tissue. Use the station's rain gauge to flag these intervals.
  5. Check temperature. Correlate the daily amplitude with sensor temperature; very high correlation on days without evaporative demand indicates a thermal artefact.
  6. Respect settling. Exclude or treat separately the initial period after installation.
  7. Only then separate GRO and TWD and compute MDS, cycle phases and rates.

Open tools exist for this. The R package dendrometeR (van der Maaten and co-workers, 2016) implements cycle-phase detection; the R package treenetproc (Knüsel and co-workers, 2021), developed within the Swiss TreeNet network, aligns time, removes spikes and shifts, documents every change made to the raw data and computes growth, water deficit, growth phenology and daily shrinkage. Using a documented tool helps reproducibility and peer review.

For the paper or report, record as metadata: species, DBH and installation height, sensor type and model, date of installation and of each intervention, logging interval, cleaning method and GRO/TWD separation method, and the source of the meteorological data.

Common mistakes

  • Installing the band in the middle of the growing season and using the first month as valid data.
  • Comparing MDS from days with very different VPD without normalising by the reference.
  • Forgetting that the measurement is over the bark: in species with thick, highly hydrated bark, the reversible change is large and masks short-term growth.
  • Logging every 6 hours and trying to extract the daily cycle. For MDS and phases, intervals of 10 to 30 minutes are usual.
  • Not recording field interventions, which makes it impossible to tell a shift from growth.
  • Calibrating a stress signal on one species and applying it to another.

The automatic band dendrometer in our catalogue

As a concrete example of an automatic dendrometer band for long-term monitoring, our catalogue includes the stem increment dendrometer with built-in data logger (ref. DRL26C, by EMS Brno, Czech Republic). According to the product page and the manufacturer's brochure:

  • increment sensor with a rotary position transducer and step-less reading, connected to a 12 × 0.2 mm stainless steel tape that wraps around the trunk; non-invasive fixing;
  • for trunks from 8 cm in diameter, with no upper limit on diameter;
  • increment range of 65 mm according to the product page and the brochure summary (the brochure's technical table states 64 mm of circumference), resolution below 1 µm and linearity of 2% of full scale;
  • tape tension of 15 to 20 N over the whole range, independent of diameter; tape thermal coefficient of 1.6 × 10⁻⁵ per degree;
  • built-in logger with 16-bit conversion, measuring accuracy of 0.1%, typical memory of 50,000 values, measuring and storing intervals of 10 min to 24 h and a clock accurate to 1 min per month between −10 and 40 °C;
  • optional internal temperature logging with ±0.3 °C accuracy, useful for the thermal correction discussed above;
  • 3.6 V, 1000 mAh lithium battery, lasting about 5 years when measuring every hour and 3 years when measuring every 10 min, according to the brochure;
  • operation from −30 to 60 °C and 0 to 100% humidity; 100 × 70 × 100 mm and about 350 g including battery;
  • data access via infrared (IrDA); the product page lists the stainless steel tape on a 20 m reel and the IrDA/USB data cable as required accessories.

For the researcher, the strength is autonomy: a sensor that measures the whole circumference, stores the data and runs for years on a battery, with no cable to a central logger. This makes it possible to spread dendrometers across a plot without power infrastructure. Do the memory arithmetic before going to the field: with 50,000 values and logging every 10 min, the memory of one channel covers about 347 days, less if temperature is also stored. Plan data downloads before that and confirm the configuration with the supplier.

Alternatives and complements in the catalogue

  • Low-cost manual band dendrometer (ref. DB20, EMS Brno): stainless steel band and buckle with scale and vernier, manual reading with 0.1 mm resolution, for trunks from 8 cm. Ideal for instrumenting many trees in a plot and for validating the automatic band on the same tree.
  • Data logger for dendrometers (ref. HS14R): weatherproof 4-channel logger with temperature compensation, 16-bit conversion, 0.2 to 0.5 µm resolution depending on the dendrometer, memory for 1.9 million readings, 1 s to 18 h interval and USB. Suitable when several dendrometers are close together, for example on neighbouring trees or at different heights on the same trunk.
  • Stem micro-variation sensor (ref. SD-5Mi): point dendrometer for stems of 5 to 25 mm, 0 to 5 mm range, resolution below 0.002 mm with filter and 4–20 mA output, used with the Aranet wireless system. Suitable for seedlings, vines and greenhouse crops.
  • Plant dendrometer (Plantsens): sensor with a range of up to 7000 µm, which can be doubled on trees with a specific holder, 0 to 2.5 V output and operation from −40 to +85 °C, aimed at vigour and stress indicators for fertigation management.
  • Relative humidity and temperature sensor with SDI-12 output (ref. SRH1A): ±1.8% RH at 25 °C and ±0.2 °C, for installation in a radiation shield. Provides the temperature and humidity for computing VPD next to the trees.
  • TDR soil moisture sensor with SDI-12 interface (ref. TDR-315H): volumetric water content, permittivity, apparent electrical conductivity and soil temperature, to separate the effect of soil dryness from that of atmospheric demand.

Checklist before requesting a quote

  1. What is the question: long-term growth, daily water deficit or irrigation management?
  2. How many trees, of which species and diameters, and with what replication per treatment?
  3. What resolution and what logging interval does the analysis require?
  4. Will the sensors be stand-alone or connected to a central logger? Is there power and telemetry on site?
  5. What travel is needed for the duration of the study, given the expected growth rate?
  6. Where are the weather station and the soil moisture measurements that will explain the signal?
  7. Who will make the visits, how often, and where are the field notebook and metadata kept?
  8. Which processing tool will be used to clean the series and separate growth from water deficit?

References

  • Zweifel, R.; Haeni, M.; Buchmann, N.; Eugster, W. Are trees able to grow in periods of stem shrinkage? New Phytologist, v. 211, p. 839–849, 2016. DOI: 10.1111/nph.13995.
  • Deslauriers, A.; Rossi, S.; Anfodillo, T. Dendrometer and intra-annual tree growth: what kind of information can be inferred? Dendrochronologia, 2007. DOI: 10.1016/j.dendro.2007.05.003.
  • Deslauriers, A.; Anfodillo, T.; Rossi, S.; Carraro, V. Using simple causal modeling to understand how water and temperature affect daily stem radial variation in trees. Tree Physiology, v. 27, p. 1125–1136, 2007.
  • Goldhamer, D. A.; Fereres, E. Irrigation scheduling protocols using continuously recorded trunk diameter measurements. Irrigation Science, 2001.
  • Goldhamer, D. A.; Fereres, E. Irrigation scheduling of almond trees with trunk diameter sensors. Irrigation Science, 2004.
  • De Swaef, T.; De Schepper, V.; Vandegehuchte, M. W.; Steppe, K. Stem diameter variations as a versatile research tool in ecophysiology. Tree Physiology, v. 35, p. 1047–1061, 2015.
  • Knüsel, S.; Peters, R. L.; Haeni, M.; Wilhelm, M.; Zweifel, R. Processing and extraction of seasonal tree physiological parameters from stem radius time series. Forests, v. 12, n. 6, 765, 2021.
  • van der Maaten, E. et al. dendrometeR: analyzing the pulse of trees in R. Dendrochronologia, 2016.
  • Muller-Landau, H. C.; Dong, S. X. Metal Band Dendrometer Protocol. CTFS/ForestGEO Global Forest Carbon Research Initiative, Smithsonian, 2010.
  • Allen, R. G.; Pereira, L. S.; Raes, D.; Smith, M. Crop evapotranspiration: guidelines for computing crop water requirements. FAO Irrigation and Drainage Paper 56. Rome: FAO, 1998.
  • Miranda, E. V. Padrão de desenvolvimento radial horário do fuste de três espécies florestais típicas da Amazônia utilizando dendrômetros automáticos. Master's thesis (Tropical Forest Sciences), INPA, 2002.
  • Brum, B. N. S. Padrões de crescimento diamétrico em comunidades arbóreas com diferentes gradientes de perturbação na Amazônia Central. Master's thesis (Tropical Forest Sciences), INPA, 2019.
  • Hofhansl, F.; Araújo, A. C.; DeLucia, E. A high-resolution monitoring network investigating stem growth of tropical forest trees. Poster, INPA/Embrapa, AmazonFACE programme.
  • EMS Brno. Dendrometer increment sensor DRL 26C with built-in datalogger, technical brochure.
  • EMS Brno. Dendrometer increment sensor DB20, technical brochure, 2017.

Instruments for this application

Back to the blog