Meteorology · Technical guides
Road surface state at the road weather station: how to measure water film, ice and pavement temperature with a remote sensor and validate the data for research
A didactic guide to road meteorology for research: why rain in the gauge is not water on the road, road surface state classes, water film and hydroplaning models (University of São Paulo study), the multispectral remote sensor principle, the estimated grip index, critical reading of the datasheet (±1 mm accuracy), surface temperature for frost and Superpave PG, an illustrative drying example, installation, validation and Brazilian references.

Anyone working on pavement engineering, road safety or transport meteorology knows this situation well: the weather station records that the rain stopped at 4 p.m., yet the road stays wet until the end of the afternoon. On a curve with a deep wheel-path rut, water still pools after the asphalt next to it has dried. At 5 a.m. on a cold night in southern Brazil the air is at 4 °C, and the deck of a bridge is still white with frost. In all these cases, what matters to the tyre is not what happens in the air but what is on the pavement surface.
That is the logic of road meteorology: besides the usual variables, measure the road surface state (dry, damp, wet, icy or snowy), the water film thickness and the surface temperature. This guide is for professors, graduate students and technicians in transport engineering, pavements, meteorology and geotechnics who want to bring this kind of measurement to an experimental section, a campus or a partnership with a highway concessionaire or road agency. The aim is to explain what a remote road surface state sensor actually measures, how to read its datasheet critically, how to install and validate it, and which research questions it helps answer. For detecting the onset and end of rain, which ties directly into this topic, see the guide to the capacitive precipitation detector.
Rain in the gauge is not water on the road
The rain gauge and the precipitation detector answer the question "is it raining, and how much?". The road answers a different one: "is there water (or ice) between the tyre and the aggregate, and how much?". The two series drift apart for several reasons:
- Drying: after the rain stops, the surface stays wet for minutes or hours, depending on solar radiation, wind, pavement temperature, texture and traffic.
- Drainage and geometry: the film depends on cross and longitudinal slope, on the length of the flow path to the edge and on defects such as wheel-path ruts, which turn into channels.
- Wetting without rain: dew, drizzle and fog wet the road without the tipping bucket recording anything.
- Water from elsewhere: runoff from embankments, shoulders and adjacent areas.
So anyone who wants to relate road condition to crashes, skid resistance or surfacing performance needs a sensor that looks at the surface, not at the sky.
Road surface state classes
Road surface state sensors usually classify the road into discrete categories. The sensor covered in this guide reports dry, moist, wet, snow, ice and slush (the Hensistemas product page renders the last one as "mixture of ice and water (frost)"). Two teaching points:
- "Moist" and "wet" are not synonyms. In general, "moist" means a thin film that darkens the surface without forming a continuous layer; "wet" means free water over the texture. The threshold between the two classes is set by the manufacturer's algorithm, not by a single standard. In your thesis, describe the classes as instrument outputs, stating the model and firmware version.
- In Brazil, almost all useful information lies in dry, moist and wet. Ice and snow matter on mountain roads in the South, on bridges and viaducts exposed to clear-sky nights and in climate-chamber research. Across most of the country the critical variable is water.
Water film and hydroplaning: what Brazilian research says
Dynamic hydroplaning occurs when, at high speed, the tyre cannot expel water from the contact patch and loses grip. A study from the Polytechnic School of the University of São Paulo (Oliveira, Kabbach Jr. and Suzuki, Transportes, 2019) reviewed methods for predicting hydroplaning speed and reached conclusions that matter directly to anyone thinking about measuring water film:
- The most cited models (NASA/Horne, Road Research Laboratory, Gallaway, Gunaratne, Gengenbach) were mostly developed more than 40 years ago, several of them with smooth tyres or aircraft tyres.
- The speed equation adopted by Gallaway is valid only for films thinner than 2.4 mm; the RRL model, due to a limitation of its original measurement method, did not record films below 1.5 mm.
- In a case study of a high-standard motorway in the São Paulo Metropolitan Region, predicted speeds varied widely depending on the combination of film and speed models, and the authors conclude that more studies are needed to link the scenario to the actual occurrence of crashes.
Film thickness in turn depends on rainfall intensity, flow path length, slope and the macrotexture of the surfacing. Macrotexture is measured in the field by the sand patch test (mean texture depth HS = 4V/(πD²), where V is the sand volume and D the mean patch diameter), and microtexture by the British pendulum, which gives the skid resistance value. In the Brazilian federal specification DNIT 031/2024-ES, which replaced 031/2006, finished asphalt concrete must reach a skid resistance value ≥ 47 on the British pendulum (ABNT NBR 16780), with the sand patch test performed per ABNT NBR 16504.
The key point for researchers: water film and hydroplaning models are calibrated with very little data measured on Brazilian roads. A sensor that continuously records road state and water thickness, alongside rainfall intensity, is exactly the kind of data that is missing to test and recalibrate these models. It is also a good starting point for quantifying exposure, that is, how many hours per year a section is wet, which is the correct denominator for wet-pavement crash rates.
How a remote road surface state sensor works
There are two families of road sensors: embedded ones, installed in a slot cut into the pavement and flush with the surface; and remote, non-contact ones, mounted on a pole beside the road and aimed at the traffic lane. A remote sensor has two practical advantages: installation requires neither cutting the pavement nor closing the lane, and it is not destroyed by milling or resurfacing.
Remote sensors of this class rely on infrared spectroscopy: the surface is observed at a few wavelengths at which liquid water, ice and snow absorb and scatter radiation differently. By comparing the signal across these channels, the algorithm estimates which phase is present and how thick it is. The manufacturer's datasheet for the sensor in this guide describes only "multispectral measurement technology" and "infrared detection", without publishing the wavelengths or the algorithm. That does not rule out research use, but it does mean treating the sensor as a black box calibrated by the manufacturer, which you must validate on your own pavement.
Two conceptual cautions:
- The "grip level" is an estimate, not a friction measurement. The sensor computes an index between 0 and about 0.8 from the detected state and layer thickness. It does not replace the British pendulum, the sand patch test or continuous friction equipment. In a paper, call it "sensor-estimated grip index" and, where possible, compare it with friction measurements on the same section.
- The sensor sees a small spot. Everything it reports applies to an area about 20 cm across. The rest of the road may be in a different state. Choosing the aiming point is part of the experimental design.
Reading the datasheet critically
By its specifications, the remote road surface state sensor in the catalogue corresponds to the HY-RSS11E model from the Chinese manufacturer HongYuv. Comparing the Hensistemas product page with the manufacturer's most recent datasheet reveals discrepancies you should know before writing your materials and methods chapter:
| Item | Product page | Manufacturer datasheet (most recent version) |
|---|---|---|
| Measuring distance | 2 to 13 m (text mentions "up to 15.5 m") | 2 to 13 m |
| Measured area diameter | 23 cm | typical 20 cm; distance:diameter ratio 30:1 |
| Installation angle | 30° to 90° | 30° to 90° (an older catalogue states 35° to 90°) |
| Water film, ice and snow | 0 to 10 mm, 0.01 mm resolution, 0.1 mm accuracy | 0 to 10 mm, 0.01 mm resolution, ±1 mm accuracy |
| Grip level | 0 to 1, 0.01 resolution | 0 to 0.82, 0.01 resolution |
| Surface temperature | −40 to +60 °C, marked as optional | −40 to +70 °C, 0.1 °C resolution, ±1 °C accuracy |
| Power supply | 220 VAC or 24 VDC; up to 4 W including lens heating | 12 to 24 VDC |
| Output | RS485 and RS232 | RS232 or RS485, ASCII or Modbus-RTU |
| Protection | not stated | IP65 |
When in doubt, follow the manufacturer's datasheet and treat the more conservative figure as the true one until you confirm it with the technical team. The most important difference is film accuracy: at ±1 mm, a reading of 0.4 mm cannot be distinguished from zero or from 1.4 mm. Since hydroplaning models work precisely in the 0.5 to 3 mm range, this defines what the sensor can and cannot answer:
- It can: classify road state minute by minute, count wet-road hours, measure drying time, detect abnormal pooling (for example in a wheel-path rut) and follow trends during an event.
- It cannot, without local validation: provide absolute thickness with sub-millimetre accuracy to calibrate a water film model. For that you need a verification test on your surfacing (see below).
Also confirm the output (Modbus-RTU or ASCII), the register map and the power supply of the unit you will receive, because they determine the data logger and the power source.
Surface temperature: the second number that matters
The same pole that carries the state sensor usually carries an infrared surface temperature sensor. This variable is useful on three fronts:
1. Ice and frost. Dew forms on the road when surface temperature drops below the dew point of the air, and frost forms when, in addition, the surface is at or below 0 °C. Illustrative example: air at 6 °C with 85% relative humidity has a dew point of about 3.7 °C (Magnus formula). If a bridge deck, which loses heat from above and below, is at 1.5 °C, condensation will occur; if it drops to −0.5 °C, the condensation turns to frost, even with the air above zero. That is why ice warnings use surface temperature and dew point, not air temperature.
2. Asphalt surfacing design and performance. In the Superpave method, the binder is chosen by the maximum and minimum pavement temperatures. The SHRP model estimates the maximum surface temperature as T_surf = T_air − 0.00618·Lat² + 0.2289·Lat + 24.4 (°C), where T_air is the average of the seven hottest daily air maxima and Lat is latitude in degrees; at 20 mm depth, T_20mm = (T_air − 0.00618·Lat² + 0.2289·Lat + 42.4)·0.9545 − 17.78. For Piracicaba (22.7° S) and T_air = 34 °C, the estimated surface temperature is about 60 °C. The FHWA report that evaluated these models against data measured in the United States found estimates on average about 5 °C above measured values at 25 mm. Researchers at the Federal University of Santa Maria (UFSM) mapped the performance grade (PG) for Brazil using 1,002 INMET stations and showed that the recommended high-temperature PG changes with the model used (SHRP or LTPP) and with the reliability level, and that, comparing 2001–2023 with 1980–2000, the high-temperature PG rose by one grade at three of the five Brazilian sites assessed. The same group developed a numerical model of the temperature profile of flexible pavements driven by solar radiation, air temperature, dew point and wind. In other words, measuring surface temperature next to a complete weather station is what allows these models to be validated in the Brazilian climate.
3. Urban climate. In Piracicaba, researchers from ESALQ/USP used an infrared thermometer to measure sunlit asphalt ranging from 27 °C to 79 °C on a summer day with a 36 °C air maximum, while asphalt shaded by trees did not exceed 35 °C. The gap between the measured peak and the SHRP estimate is not a contradiction: the model estimates a design value from averages of maxima, while a spot measurement captures the instantaneous peak.
The fundamentals of infrared thermometry (field of view, emissivity, reflected sky) are explained in the guide on canopy temperature with an infrared sensor. The same rules apply to pavement, with one detail: dry asphalt and concrete have high emissivity in the thermal infrared (typically 0.90 to 0.95), but the presence of water changes the surface the sensor sees. Record road state alongside temperature and analyse dry and wet periods separately.
Illustrative example: a summer rain afternoon
The numbers below are illustrative, only to show how to read the series (they are not measurements):
- 3:08 p.m.: the precipitation detector switches to "raining". The road sensor still reads "dry": the first water is absorbed by the texture.
- 3:12 p.m.: state "moist". 3:18 p.m.: state "wet", reported film 0.6 mm.
- 3:30 to 3:50 p.m.: heavy rain; the reported film rises to 2.1 mm in the observed wheel path.
- 3:55 p.m.: the rain stops. The film drops quickly, but the state stays "wet" until 4:35 p.m.
- 4:35 to 5:20 p.m.: "moist". 5:20 p.m.: "dry".
Correct reading: the drying time (from the end of rain to "dry") was about 85 minutes, and the road was wet or moist for 2 h 08 min, although the rain gauge recorded rain for only 47 minutes. Incorrect reading: stating that the maximum film was "2.10 mm". With ±1 mm accuracy, the correct statement is about 2 mm, with ±1 mm uncertainty, or use thickness only as a relative indicator within the event.
Installation: geometry, aiming point and safety
- Distance and height. The datasheet allows 2 to 13 m between sensor and target. With a 30:1 ratio, the spot is about 20 cm at 6 m; if the relationship is linear, it reaches about 43 cm at 13 m. At oblique incidence the spot becomes an ellipse stretched along the line of sight (at 45°, the major axis is about 1.4 times the diameter).
- Angle. Stay within 30° to 90° relative to the surface. Very shallow angles enlarge the spot and increase the influence of reflections.
- Aiming point. For hydroplaning and skid resistance studies, aim at the wheel path of the right-hand lane, where water accumulates and heavy traffic runs. Avoid painted markings, joints, covers, patches and the pole's own shadow. Document it with a photo and a sketch.
- Material. The datasheet indicates use on concrete and asphalt. For porous friction courses, interlocking blocks or permeable pavements, confirm behaviour with the manufacturer and validate locally.
- Lens and power. Lens heating prevents condensation; size the power supply for the maximum consumption (up to 4 W, according to the product page). The manufacturer states automatic lens contamination compensation, but include periodic cleaning in the protocol, because tyre spray and road dust soil the optics.
- Safety and authorisation. Install outside the road's clear zone or behind a guardrail, with authorisation from the road authority or concessionaire. Never plan maintenance that requires entering the lane without traffic control.
What the station needs
A research road monitoring site needs, besides the state sensor:
- A precipitation detector to mark the onset and end of rain with minute resolution, and a rain gauge for intensity, which is the input to water film models.
- Air temperature and relative humidity in a shield, for the dew point. Installation details are in the guide to air temperature and humidity at the weather station.
- Global solar radiation and wind, which drive drying and the pavement energy balance.
- Infrared surface temperature, as redundancy and for thermal analysis.
- Visibility, if the objective includes fog and road safety; see the guide to atmospheric visibility.
- A data logger with an RS485 Modbus-RTU master port, SDI-12 input and telemetry, with a single clock in UTC and a 1-minute interval for road state and temperature. Communication options are covered in weather station telemetry.
Validation and quality control
- Synchronised visual check. A camera aimed at the same spot, saving an image every few minutes, is the cheapest way to validate the dry/moist/wet classes. Build a confusion matrix between the sensor class and the visual class.
- Known-thickness test. To check film thickness, place a slab of the same surfacing (or an isolated area with sealed edges) under the sensor and apply known volumes of water: mean thickness is volume divided by area. Repeat on a new and a worn surface. Remember that on textured surfaces part of the water is "hidden" in the macrotexture; record the sand patch depth of the specimen.
- Temperature. Compare the sensor's surface temperature with a thermocouple bonded to the surface or with a reference infrared thermometer during a dry period, and record the difference.
- Consistency between sensors. A "wet" state with no rain, no likely dew (surface well above dew point) and no report of washing or spills is suspicious. So is a "dry" state while the rain detector has been active for many minutes.
- Lens. Record cleaning dates and check whether the signal changes afterwards. If the sensor exports a lens contamination indicator, archive it.
- Raw and derived data. Archive the original outputs (class, thicknesses, grip index, temperature) and compute drying time and wet hours in post-processing, with the algorithm described in your methods.
Research questions this measurement helps answer
- How long does a surfacing take to dry after rain, and how does that vary with radiation, wind, texture and surfacing type (dense, porous, concrete)?
- Do the water film models used in Brazil reproduce what is observed on a real section during intense rain events?
- How many hours per year is a section wet, and how does that exposure change wet-pavement crash rates?
- How often does the surface of mountain bridges and viaducts in southern Brazil drop below the dew point and 0 °C, compared with the road on embankment?
- Does the maximum measured surface temperature confirm the PG estimated by the SHRP and LTPP models for the site?
How to choose
- I want to know whether the road is dry, moist, wet or icy without cutting the pavement: the remote road surface state sensor, with state classes, water, ice and snow thickness, grip index and serial output.
- I only need surface temperature (road, bridge, soil or canopy) at low power: the infrared road temperature sensor, 8 to 14 µm, with RS485 Modbus output.
- I want to integrate everything in a logger with telemetry: the weather station data logger with cellular module, with an RS485 Modbus-RTU port configurable as master, an SDI-12 port and analogue inputs.
- I need wind, temperature, humidity, pressure and rain in a single body, with Modbus output: the professional ultrasonic weather station.
Related products
- Remote road surface state sensor (ref. EIC-28RSS11E): main instrument in this guide.
- Infrared road temperature sensor (ref. HS14IRS2E): surface temperature from −40 to 70 °C, 8:1 distance-to-target ratio, RS485 Modbus.
- Weather station data logger with cellular module (ref. HD33MT.4): Modbus-RTU master, SDI-12, alarms and mobile data transmission.
- Relative humidity and temperature sensor with SDI-12 output (ref. SRH1A): basis for the dew point in frost warnings.
- Rain detector (ref. HD2013.2): rain onset and end, with a heater against false dew and fog signals.
- Professional ultrasonic weather station (ref. HS14EMD): ultrasonic wind, temperature, humidity, pressure and radar precipitation, with Modbus output.
- Visibility detector (ref. HS-VTF14306BE): fog and visibility for road safety studies.
- Spectrally flat class B pyranometer (ref. LPPYRA02): global solar radiation for the energy balance and road drying.
Checklist before taking the road sensor into your thesis
- Does your research question depend on road state, film thickness, or both? If thickness, is a verification test planned?
- Has the datasheet's ±1 mm accuracy been considered in the analysis and discussion?
- Is the aiming point (lane, wheel path, material) documented with a photo and sketch?
- Are installation distance, height and angle within the manufacturer's range and recorded?
- Are rain, air temperature and humidity, radiation and wind on the same logger, in UTC, at a 1-minute interval?
- Is there a camera or other synchronised visual check to validate the classes?
- Are the lens cleaning routine and maintenance dates recorded?
- Do your methods describe the model, firmware and the definitions of drying time and wet hour?
If the answer is "yes" to all of them, road state stops being a driver's impression and becomes scientific data.
References
- Oliveira, H. F.; Kabbach Jr., F. I.; Suzuki, C. Y. Utilização de métodos de previsão da velocidade de ocorrência de aquaplanagem para verificação da segurança em rodovias de alto padrão. Transportes, v. 27, n. 4, 2019. DOI: 10.14295/transportes.v27i4.1735.
- Faccin, C.; Specht, L. P.; Pereira, D. S.; Schuster, S. L.; Brondani, C.; Guex, G. G.; Vestena, P. M. Desenvolvimento de um modelo de previsão do perfil de temperatura de pavimentos flexíveis. Transportes, v. 32, n. 2, e2984, 2024. DOI: 10.58922/transportes.v32i2.2984.
- Faccin, C.; Schuster, S. L.; Almeida Jr., P. O. B.; Vestena, P. M.; Specht, L. P.; Bueno, L. D.; Leite, L. F. M. Mapas de grau de desempenho (PG) de ligantes asfálticos para o Brasil. In: 35th Congress of Research and Teaching in Transportation (ANPET), 2021.
- Faccin, C.; Specht, L. P. Impacto do aumento da temperatura na seleção de ligantes e desempenho à deformação permanente de pavimentos asfálticos. Transportes, v. 34, e3218, 2026. DOI: 10.58922/transportes.v34.e3218.
- Mendes, F. H.; Polizel, J. L.; Romero, H.; Silva Filho, D. F. Quanto uma superfície urbana pode aquecer-se no verão e no inverno tropical. In: 9th Luso-Brazilian Congress for Urban, Regional, Integrated and Sustainable Planning (PLURIS), 2021.
- Mohseni, A. LTPP Seasonal Asphalt Concrete (AC) Pavement Temperature Models. Federal Highway Administration, Report FHWA-RD-97-103, 1998.
- DNIT. DNIT 031/2024-ES – Pavimentação – Concreto asfáltico – Especificação de serviço. Brazilian National Department of Transport Infrastructure, 2024.
- World Meteorological Organization. Guide to Instruments and Methods of Observation (WMO-No. 8), chapter on road meteorological measurements.
- HongYuv Technology. HY-RSS11E non-contact road state sensor: datasheet.
- Hensistemas product page: remote road surface state sensor.
Instruments for this application

EIC-28RSS11E
EIC-28RSS11E Road surface condition sensor

HenSistemasHS14IRS2E
HS14IRS2E Infrared Road Temperature Sensor

DeltaOhm - GHM GroupHD33MT.4
HD33MT.4 Data Logger for Weather Station

DeltaOhm - GHM GroupHD2013.2
HD2013.2 – Rain Detector

HenSistemasHS14EMD
HS14EMD Professional Ultrasonic Weather Station

HenSistemasHS-VTF14306BE
HS-VTF14306BE Visibility Detector

DeltaOhm - GHM GroupLPPYRA02