Meteorology · Air quality · Technical guides
Ozone and NO₂ in research: how to measure gaseous pollutants with an air quality station, calibrate the electrochemical sensor and use the weather station
A teaching guide to measuring O₃, NO₂, CO and SO₂ with a compact air quality station: Brazil's Conama 506/2024 standards and averaging periods, ppb ↔ µg/m³ conversion with pressure and temperature (worked example), electrochemical sensor vs. reference method, NO₂ interference on ozone, photochemistry and total oxidant Ox, mixing layer and pollution rose, humidity artifacts, collocation against US EPA targets, siting, quality control and Brazilian studies.

Measuring ozone and nitrogen dioxide is no longer the exclusive domain of official networks. Today, environmental engineering, public health, geography, atmospheric chemistry and data science groups at Brazilian public universities install compact air quality stations with electrochemical sensors on campuses, at schools, along traffic corridors, in industrial districts and in mid-sized cities that have never had a reference station.
The promise is real: spatial density, real-time data and a much lower cost. So is the risk: an electrochemical ozone sensor that confuses O₃ with NO₂, a baseline that “walks” with humidity, or a ppb-to-µg/m³ conversion done at the wrong pressure can produce an entire paper built on an artifact.
This guide is for professors, graduate students and technicians who want to measure gaseous pollutants (O₃, NO₂, CO and SO₂) with an air quality station, calibrate it in the field and interpret the data together with the weather station. We have already covered PM2.5 and PM10 particulate matter, which has its own physics and corrections. The focus now is on gases — and on why, for them, meteorology is not context: it is part of the equation.
The four gases and what Brazilian law requires
Conama Resolution 506/2024 replaced Resolution 491/2018 and organized Brazil's national standards in stages: interim standards PI-1 to PI-4 and a final standard (PF), aligned with the 2021 WHO guideline values. PI-2 has been in force since 1 January 2025. For gases, the values most used in research are:
| Pollutant | Averaging period | PI-2 (in force) | PF (final target) |
|---|---|---|---|
| Ozone (O₃) | daily maximum 8-h moving average | 130 µg/m³ | 100 µg/m³ |
| Nitrogen dioxide (NO₂) | daily maximum hourly average | 240 µg/m³ | 200 µg/m³ |
| Sulfur dioxide (SO₂) | 24 h | 50 µg/m³ | — (PI-4: 20 µg/m³) |
| Carbon monoxide (CO) | maximum 8-h moving average | 9 ppm (PF already adopted) | 9 ppm |
Two teaching points matter here. First, the averaging period is part of the standard: comparing a 1-minute reading with an 8-hour limit is a conceptual error, not a detail. Second, the law is written in µg/m³, while almost every gas sensor reports ppb or ppm. The bridge between the two units depends on temperature and pressure — and that is where the weather station comes in for the first time.
From ppb to µg/m³ (and why pressure matters)
The conversion comes from the ideal gas law:
concentration (µg/m³) = concentration (ppb) × M / Vm
where M is the molar mass of the gas (O₃ = 48.00 g/mol; NO₂ = 46.01; SO₂ = 64.07; CO = 28.01) and Vm is the molar volume, 24.45 L/mol at 25 °C and 1013.25 hPa. Under those conditions:
- 130 µg/m³ of O₃ ≈ 66 ppb; the PF of 100 µg/m³ ≈ 51 ppb;
- 240 µg/m³ of NO₂ ≈ 128 ppb; 200 µg/m³ ≈ 106 ppb;
- 50 µg/m³ of SO₂ ≈ 19 ppb;
- 9 ppm of CO ≈ 10.3 mg/m³.
Now a numerical field example. A sensor reads 60 ppb of O₃ in a highland city at 920 hPa and 20 °C. The local molar volume is Vm = 22.414 × (293.15/273.15) × (1013.25/920) ≈ 26.5 L/mol, which gives about 109 µg/m³ at local conditions. At 25 °C and 1 atm, the same 60 ppb becomes about 118 µg/m³. That is almost an 8 % difference — enough to change the count of exceedances. So record pressure and temperature alongside the gas and state in your methods which reference condition you used, checking the one adopted by your state environmental agency. We cover pressure measurement in atmospheric pressure at the weather station.
Reference method vs. electrochemical sensor
Official networks use analyzers with specific principles: UV absorption photometry for O₃, chemiluminescence for NO₂, UV fluorescence for SO₂ and non-dispersive infrared for CO. They are bench instruments in climate-controlled shelters with traceable calibration.
Compact stations generally use amperometric electrochemical cells: the gas diffuses through a membrane, reacts at a working electrode and produces a current proportional to concentration. The technology is cheap, low-power and offers good resolution — but it has three weaknesses every researcher must know:
- Cross-sensitivity. Many electrochemical ozone sensors also respond to NO₂, because both are oxidants. Near an avenue, with 40 ppb of O₃ and 50 ppb of NO₂, an uncorrected “oxidant” sensor may read something close to the sum if its NO₂ sensitivity is similar to its O₃ sensitivity. That is why serious stations measure NO₂ on a separate channel and correct O₃ by subtraction or modeling.
- Baseline dependent on temperature and humidity. The “zero” current changes with temperature, and rapid humidity changes produce transients. Datasheets mention “temperature compensation”, but factory compensation does not replace field calibration in the climate where the sensor will work.
- Drift and service life. Sensitivity decreases over time. The datasheets of the instruments in this guide state a service life of 2 to 3 years for the gas sensors, and the literature shows relevant drift within weeks to months.
Mead et al. (2013) showed that dense networks of electrochemical sensors can resolve street-to-street variation in NO and NO₂, provided data processing is careful. Spinelle et al. (2015) field-tested several O₃ and NO₂ sensors and concluded that calibration models including temperature, humidity and the interfering gas perform far better than a simple straight line.
Read the datasheet like a researcher
Before buying, compare range, resolution and accuracy with the standard you want to assess:
- Accuracy expressed as % of full scale can be misleading. An ozone sensor with a 0–10 ppm range and ±6 % of full scale accuracy allows an error of ±600 ppb — almost ten times the 8-hour standard. That type of sensor exists for indoor environments, HVAC or industrial safety, not for outdoor air quality.
- For ambient O₃ and NO₂, look for ranges in the hundreds of ppb and resolution of a few ppb. The HS-EMQA air quality monitoring station, for example, states a 0–500 ppb range and 3 ppb resolution for O₃, NO₂ and SO₂.
- For SO₂, typical urban levels range from a few ppb to tens of ppb. Ask the manufacturer for the detection limit — not just the range.
The instrument: a compact multi-parameter station with gas sensors
The main instrument in this guide is the OSTARA air quality monitoring station. According to the product page, it combines:
- Plug-and-play gas sensors with temperature compensation and an estimated service life of 3 years: CO, H₂S, NH₃, NO₂, O₂, O₃, SO₂, VOC and odors. The datasheet lists a standard range of 5 ppm for O₃ and NO₂, 10 ppm for CO and 50 ppm for SO₂, with a value in parentheses (0.001 ppm for O₃, CO and SO₂; 0.01 ppm for NO₂) that should be confirmed with the manufacturer as the reading step and detection limit of the chosen version;
- Particulate matter PM1, PM2.5 and PM10 (0–1000 µg/m³);
- Integrated meteorology: temperature (±0.1 °C), relative humidity (±1.5 %RH) and pressure (0.1 mbar accuracy at 25 °C) inside the enclosure, plus an interface for an external ultrasonic anemometer (0.12–40 m/s, ±1° in direction);
- GNSS and calculated indices (dew point, wind chill, European and French air quality indices);
- 2G/3G/4G LTE communication (FTP/SMTP), Wi-Fi with a built-in web interface, the Inoview online platform and Modbus integration with a water quality probe;
- IP66 glass-fiber-reinforced polyester enclosure, IK10 impact resistance, operation from −20 °C to +55 °C, autonomous solar power or mains power.
What matters to the researcher is the combination: gas, temperature, humidity, pressure and wind in the same record and on the same clock. That is exactly the set of variables you need to correct the sensor, convert units and interpret the concentration.
Meteorology inside the concentration
Radiation and temperature: the ozone factory
Tropospheric ozone is not emitted: it forms from nitrogen oxides and volatile organic compounds in the presence of sunlight. The basic cycle is simple:
- NO₂ + light (wavelength below ~420 nm) → NO + O
- O + O₂ → O₃
- NO + O₃ → NO₂ + O₂
The first two reactions produce ozone; the third consumes it. This explains two patterns found in any data series. Ozone peaks in the early afternoon, following solar radiation, and is higher on hot, sunny days. And near large NO sources (avenues), ozone is often lower than in downwind neighborhoods, because fresh NO consumes it.
The 2024 Environmental Quality Report of the State of São Paulo illustrates the role of weather: in 2023, the state 8-hour ozone standard (130 µg/m³) was exceeded on 57 days in the São Paulo Metropolitan Region, with the highest concentrations in spring and summer, associated with high-temperature, high-radiation days.
For research, this means: measure global solar radiation next to ozone (see pyranometer at the weather station) and also work with total oxidant Ox = O₃ + NO₂. Because NO converts O₃ into NO₂ without destroying oxidant, Ox varies less between nearby sites and separates local chemistry from regional ozone.
Mixing layer, inversions and wind: the fate of primary pollutants
CO and NO₂ are mostly primary (or formed very close to the source). Their level depends on how much air is available to dilute them. On cold nights and winter early mornings, with a temperature inversion and a shallow mixing layer, concentrations rise; with sun and wind, the layer grows and dilutes them. That is why urban NO₂ usually peaks during the morning rush hour and has higher averages in winter.
Wind is the most underrated diagnostic tool. By crossing concentration with wind direction and speed you build a pollution rose (mean concentration by direction sector) and identify where the pollutant comes from: the highway to the east, the factory to the south, the fire to the northwest. Calm periods mark accumulation episodes. For this, wind direction must be measured at the same site and with good resolution — see wind measurement at the weather station.
Humidity: the artifact that mimics pollution
In electrochemical sensors, abrupt changes in relative humidity — the end of a rain shower, dawn dew, a passing front — can produce false peaks or dips in concentration. If your “pollution episode” coincides with a humidity jump and does not appear at the neighboring site, be suspicious. Store humidity with the gas data and use it both as a calibration model variable and as a quality control criterion. On humidity measurement, see air temperature and humidity at the weather station.
Field calibration: collocation with the reference station
No compact station should enter a thesis without a collocation period next to a reference analyzer — ideally an official network station (CETESB, INEA, state agencies) or a university laboratory.
How to do it:
- Install the station a few meters from the reference analyzer's air inlet, at practically the same height.
- Collect at least several weeks — the US EPA base testing protocol for ozone sensors calls for campaigns of at least 30 days with three identical units. If possible, include high-ozone days and inversion days.
- Work with paired hourly averages and discard hours with insufficient data coverage.
- Fit a calibration model. Start with simple linear regression (reference vs. sensor) and move to multiple linear regression with temperature, humidity and the interfering gas (NO₂ for O₃). Non-parametric models (k-nearest neighbors, random forests) can perform better (Sahu et al., 2021), but require training data covering the range of meteorological conditions in the deployment period.
- Collocate again at the end of the campaign. Mijling et al. (2018) obtained R² of 0.3–0.7 for NO₂ sensors calibrated with simple regression; adding temperature and humidity raised R² to 0.6–0.9 — and all sensors showed significant drift within two months. Data between calibrations can be corrected by interpolating the coefficients over time.
Reference performance targets (US EPA, base testing, 1-h averages):
| Metric | Ozone | Nitrogen dioxide |
|---|---|---|
| R² | ≥ 0.80 | ≥ 0.70 |
| Slope | 1.0 ± 0.2 | 1.0 ± 0.35 |
| Intercept | −5 to +5 ppb | −5 to +5 ppb |
| RMSE | ≤ 5 ppb | ≤ 5 ppb |
These targets were created for supplemental and informational, non-regulatory monitoring. Use them as a yardstick to report your data quality, and state clearly that the compact station complements — not replaces — the official network.
In Brazil, this path is already being followed: the QUALARIA project calibrated low-cost sensors next to CETESB's Cerqueira César station, inside the USP School of Public Health, before distributing them across the São Paulo Metropolitan Region; at Unioeste, Roncaglio (2023) compared a prototype with commercial and reference stations and showed that simple linear models fail to capture sensor nuances, while random forests performed better.
Where to install the station
- Define the question before the site. Population exposure? Influence of a road? Regional ozone? Each question calls for a different location (sidewalk, schoolyard, low rooftop, open area downwind of the city).
- Height and free airflow. The air inlet must be unobstructed, away from walls, exhaust fans, kitchen chimneys, parking lots and dense vegetation that blocks the wind.
- Enclosure shading and ventilation. Electrochemical sensors suffer from high internal temperature. Prefer sites where the enclosure is not exposed to direct sun all day without ventilation, respecting the operating range on the datasheet.
- Metadata. Photograph all four sides, record coordinates, height, distance to the nearest road and curb, and land use. Without this, the data are not comparable.
- Same clock. Set time to UTC (or document the time zone) and check that the weather station and the air quality station are synchronized. A one-hour offset destroys a rush-hour peak analysis.
If the station is far from mains power, size the panel and battery for the worst month and use cellular transmission with local storage; we cover this in weather station telemetry.
Data quality control
- Warm-up period: discard the first hours (or the period stated on the datasheet) after switching on or replacing a sensor.
- Physical limits: persistent negative values, saturation at the top of the range and minute-to-minute jumps with no counterpart at a neighboring site should be flagged.
- Chemical consistency: high O₃ at 3 a.m. next to an avenue is suspicious; NO₂ and CO should rise together during traffic episodes; Ox should vary smoothly.
- Meteorological consistency: cross-check with radiation (O₃), with wind and mixing-layer height (primary pollutants) and with humidity (artifacts).
- Regulatory averages: compute averages with a minimum coverage rule (for example, 75 % of hours) and apply the right period — maximum 8-h moving average for O₃ and CO, maximum hourly value for NO₂, 24 h for SO₂.
- Version the calibration: keep raw data, coefficients and corrected data in separate columns, with the date of each calibration.
How to choose
- I want a network of sites with gases, particles and meteorology in one solar-powered unit: a compact multi-parameter station with an anemometer interface — the OSTARA.
- I need a ppb range for O₃, NO₂ and SO₂ with cellular transmission: the HS-EMQA station.
- I want a lightweight monitor with cloud and SD card for many sites: the TSI BlueSky air quality station, with electrochemical sensors for CO, O₃, NO₂ and SO₂ and NDIR for CO₂.
- I already have gas sensors and need quality meteorology: add an ultrasonic anemometer, a pyranometer and a weather station data logger.
Related products
- OSTARA air quality monitoring station: the main instrument in this guide — gases, particles, temperature, humidity, pressure and a wind interface.
- HS-EMQA air quality monitoring station: O₃, NO₂ and SO₂ in the ppb range, CO, PM and VOC, with GPRS.
- TSI BlueSky air quality station (ref. 8145): lightweight monitor with cloud, SD card and electrochemical gas sensors.
- 2-axis ultrasonic anemometer (ref. HD52.3D): direction and speed for the pollution rose.
- Spectrally flat class B pyranometer (ref. LPPYRA02): solar radiation, the driver of ozone.
- Air pressure transmitter with SDI-12 output (ref. SP1A): pressure for the ppb ↔ µg/m³ conversion.
- Relative humidity and temperature sensor with SDI-12 output (ref. SRH1A): calibration model variables.
- All-in-one compact weather station (ref. HDMCS-200): complete meteorology in a single body.
- Weather station data logger with cellular module (ref. HD33MT.4): acquisition and telemetry of meteorological variables.
Checklist before using the data in your thesis
- Does the averaging period of each indicator match the Conama 506/2024 standard (8 h for O₃ and CO, 1 h for NO₂, 24 h for SO₂)?
- Did the ppb ↔ µg/m³ conversion use pressure and temperature stated in the methods?
- Was there collocation with a reference before and after the campaign, with metrics (R², slope, intercept, RMSE) reported?
- Was ozone corrected for NO₂ interference?
- Did temperature and humidity enter the calibration model?
- Are an anemometer and solar radiation measured at the same site and on the same clock?
- Were extreme episodes checked against humidity, wind and neighboring sites?
- Are raw data, coefficients and corrected data archived separately?
References
- Brazil. National Environment Council. Conama Resolution No. 506 of 5 July 2024. Establishes national air quality standards.
- Rio de Janeiro State Environmental Institute (INEA-RJ). SIGQAR Portal — Air quality standards (table of Conama Resolution 506/2024).
- São Paulo State. SEMIL. Relatório de Qualidade Ambiental 2024 — Meio Ambiente Paulista. São Paulo, 2024.
- U.S. EPA. Performance Testing Protocols, Metrics, and Target Values for Ozone Air Sensors. EPA/600/R-20/279, 2021.
- U.S. EPA. NO2, CO, and SO2 Supplement to the 2021 Report on Performance Testing Protocols, Metrics, and Target Values for Ozone Air Sensors. 2024.
- Mead, M. I. et al. The use of electrochemical sensors for monitoring urban air quality in low-cost, high-density networks. Atmospheric Environment, v. 70, p. 186–203, 2013. DOI: 10.1016/j.atmosenv.2012.11.060.
- Spinelle, L.; Gerboles, M.; Villani, M. G. et al. Field calibration of a cluster of low-cost available sensors for air quality monitoring. Part A: Ozone and nitrogen dioxide. Sensors and Actuators B: Chemical, v. 215, p. 249–257, 2015. DOI: 10.1016/j.snb.2015.03.031.
- Mijling, B.; Jiang, Q.; de Jonge, D.; Bocconi, S. Field calibration of electrochemical NO₂ sensors in a citizen science context. Atmospheric Measurement Techniques, v. 11, p. 1297–1312, 2018. DOI: 10.5194/amt-11-1297-2018.
- Sahu, R. et al. Robust statistical calibration and characterization of portable low-cost air quality monitoring sensors to quantify real-time O₃ and NO₂ concentrations in diverse environments. Atmospheric Measurement Techniques, v. 14, p. 37–52, 2021. DOI: 10.5194/amt-14-37-2021.
- Roncaglio, M. M. Estação de baixo custo para monitoramento da qualidade do ar. Master's thesis (Computer Science) — Western Paraná State University (Unioeste), Cascavel, 2023.
- QUALARIA Project. Sensores em calibração: QUALARIA avança para garantir dados confiáveis na RMSP. MeteoIA.
- Hensistemas product page: OSTARA air quality monitoring station.
Instruments for this application

nke InstrumentationOSTARA
OSTARA Air Quality Monitoring Station

HenSistemasHS-EMQA
HS-EMQA Air Quality Monitoring Station (PM2.5, PM10, CO, SO2, NO2, O3, TVOC, Temperature, Humidity)

DeltaOhm - GHM GroupHD52.3D
HD52.3D Series – 2-Axis Ultrasonic Anemometer

DeltaOhm - GHM GroupLPPYRA02
LPPYRA02 Series Spectrally Flat Class B (First Class) Pyranometer

DeltaOhm - GHM GroupHDMCS-200
HDMCS-200 All-in-One Meteo Compact Station

DeltaOhm - GHM GroupHD33MT.4





