Kits and Solutions

Aranet Ammonia-Resistant Wireless Temperature and Relative Humidity Probe

Reference
TDSPT4
Brand
Aranet

Battery-powered wireless sensors that deliver highly accurate temperature and relative humidity readings in harsh environments, above all where ammonia levels run high, such as cattle and poultry farming.

The ammonia-resistant Aranet T/RH probe works with Aranet Cloud.

Price on request

No sign-up. You review the list and send it when you are ready.

TDSPT4

Torn between two models?

Ask on WhatsApp
  • Compatibility Aranet base stations only
  • Compatible base stations Aranet PRO
  • Measurements Temperature and relative humidity in chemically aggressive environments
  • Measuring range T: -40 °C to 60 °C; RH: 0-100 %
  • Resolution T: 0.1 °C; RH: 0.1 %
  • Accuracy T: ±0.3 °C (0 to +60 °C); RH: ±2 % (at +50 °C, 0 to 80 % RH)

Overview

Applications

  • Livestock
  • Poultry farms
  • Pharmacy

Specifications

The sensors work only with Aranet base stations.

  • Measurements: temperature and relative humidity in chemically aggressive environments
  • Measuring range: T: -40 °C to 60 °C; RH: 0-100 %
  • Resolution: T: 0.1 °C; RH: 0.1 %
  • Accuracy¹: T: ±0.3 °C²; RH: ±2 %³
  • Hysteresis: T: N/A; RH: ±1 %
  • Long-term drift: T: 0.05 °C/year; RH: 0.5 %/year⁴
  • Line-of-sight range: up to 3 km
  • Operating environment: indoor and outdoor use
  • Supported ISM bands: EU868, NA915
  • Transmitter power: 14 dBm
  • Data transmission interval⁵: 1, 2, 5, 10 minutes
  • Data protection: XXTEA encryption
  • Compatible base stations: Aranet PRO
  • Ingress protection: IP67
  • Maximum operating temperature range: -40 °C to 60 °C
  • Battery life: up to 10 years
  • Dimensions: Ø 35 x 130 mm
  • Weight⁶: 100 g
  • Housing material: ASA plastic
  • In the box: 1 AA alkaline battery, wire
  • Power supply: 1 AA battery
  • Compliance: CE, IC, FCC
  • Part number by region: TDSPT409 (EU), TDSPT4U9 (NA), TDSPT4R9 (RU)

Notes

  • ¹ At the time of sale, 99 % of sensors read within these typical limits at steady state. When working out the total measurement error, take hysteresis and long-term drift into account as well.
  • ² Temperature accuracy applies over 0 … +60 °C.
  • ³ Humidity accuracy applies at +50 °C over 0 … 80 % RH.
  • ⁴ The relative humidity drift figure comes from laboratory conditions: +23 °C and 30 % to 70 % relative humidity. Long exposure above +50 °C may increase long-term drift.
  • ⁵ Because of regulatory requirements, the 1 minute data transmission interval is not available in Russia.
  • ⁶ Weight includes a Fujitsu LR6G07 Premium AA alkaline battery.

Catalog

Aranet product line

Related products

What do you need to measure?

Tell HenSistemas about your application.