HenSistemasHS14F6000-P
Electrical Energy (kWh and kW)
The HS146000E handheld three-phase power quality analyzer with CT offers the best capability in power quality analysis: it helps locate, predict, prevent and troubleshoot power quality problems in three-phase and single-phase power distribution systems.
It also offers a patented energy loss algorithm, unified power measurement, and measuring and counting of energy losses due to harmonics and unbalance issues, allowing the user to pinpoint the origin of energy losses in the system.
Price on request
No sign-up. You review the list and send it when you are ready.
Torn between two models?
Ask on WhatsAppSaves this product and the next ones you view in this browser, up to eight, for 30 days. You can disable it under “History” in the footer.
History is enabled in this browser. History
| Property | Value |
|---|---|
| Electrical parameters — voltage | rms, ava, pk+, pk-, rms-1/2, CF |
| Electrical parameters — frequency | Freq |
| Electrical parameters — current | rms, ava, pk+, pk-, rms-1/2, CF |
| Electrical parameters — power and energy | P, S, Q, PF, DPF, W |
| Electrical parameters — compilation | THD, DC, 1-50 Harm, 1-50 InHarm, 1-35 HiHarm, 1-50 SubHarm |
| Electrical parameters — harmonic voltage | THD, DC, 1-50 Harm, 0-49 InHarm, 1-35 HiHarm, 1-50 SubHarm, KF |
| Electrical parameters — harmonic current | THD, DC, 1-50 Harm |
| Electrical parameters — harmonic power | Ia, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutes |
| Electrical parameters — fluctuation and flicker | PST, PLT, Fluct, Fluct Max |
| Electrical parameters — unbalance (Unbal) | V pos, A pos, V neg, A neg, A zero, V zero, Unbal |
| Electrical parameters — event log | Voltage swell, voltage sag, DIP, inrush current, voltage and current distortion out of limit, odd harmonic content out of limit, voltage and current unbalance out of limit, frequency out of limit, PST out of limit, PLT out of limit, long-term voltage interruption, voltage fluctuation deviation |
| P, Q, S — measurement types | P: calculated every 10 cycles; S: calculated from the RMS value of voltage and current; Q: calculated from apparent power and active power |
| P, Q, S — display | Table charts, trend chart |
| P, Q, S — measuring range/resolution | According to the voltage and current range |
| P, Q, S — measurement accuracy | ±0.5% |
| RMS current (Arms) — measurement mode | Calculated as the root mean square over 10 cycles |
| RMS current (Arms) — display mode | Current RMS value of each channel |
| RMS current (Arms) — measuring range/resolution | Current: according to the current clamps. Options: 5A/50A/100A/500A; flexible current clamps: 1200A/3000A/6000A |
| RMS current (Arms) — accuracy | 0.1% + accuracy of the current clamps |
| Frequency — measurement mode | Calculated every 10 cycles (50Hz) or (60Hz) |
| Frequency — display mode | Measurement over 10 cycles |
| Nominal frequency/resolution | 50.000Hz/0.001Hz or 60.000Hz/0.001Hz |
| Frequency — measuring range | 42.5-57.5Hz or 52.5-67.5Hz |
| Frequency — measurement accuracy | ±0.001Hz |
| Half-wave RMS current/voltage — measurement mode | Calculated every 2 cycles; in each cycle, 1/2 cycle made up of one waveform calculation |
| Half-wave RMS current/voltage — measuring range/resolution | Voltage: 120V/0.01V, 230V/0.01V, 400V/0.01V, 1000V/0.01V; current: according to the current clamps |
| Half-wave RMS current/voltage — measurement accuracy | ±0.1% |
| RMS voltage (Vrms) — measurement circuit | 1P2W / 2P3W / 3P3W / 3P4W |
| RMS voltage (Vrms) — base frequency of the measurement circuit | 50Hz |
| RMS voltage (Vrms) — input channels | Voltage: 4 phases; current: 4 phases |
| RMS voltage (Vrms) — measuring range | Voltage: standard 120V, 230V, 400V and 1000V, maximum instantaneous voltage 1000V; current: according to the current clamps (only current clamps with voltage signal output are supported) |
| Power factor — measurement mode | Ratio between average power and apparent power |
| Power factor — display mode | Real-time data |
| Power factor — measuring range/resolution | -1.000-1.000/0.001 |
| Power factor — measurement accuracy | ±1% |
| Harmonics (Vfund, Afund, harmonic power) — measurement mode | Complies with IEC61000-4-7; the analysis time window is ten cycles |
| Harmonics (Vfund, Afund, harmonic power) — indicator points | 5120 points |
| Harmonics (Vfund, Afund, harmonic power) — display mode | Waveform, trend charts, histograms |
| Harmonics (Vfund, Afund, harmonic power) — number of measurements | 1-50 times |
| Harmonics (Vfund, Afund, harmonic power) — measurement accuracy | Vfund >1%: error <1%; Vfund <1%: error <0.05% of nominal voltage; Afund >3%: error <1%; Afund <3%: error <0.05% of current range |
| InHarm voltage, InHarm current — measurement mode | Complies with IEC61000-4-7; the analysis time window is ten cycles |
| InHarm voltage, InHarm current — indicator points | 5120 points |
| InHarm voltage, InHarm current — display mode | Waveform, trend charts, histograms |
| InHarm voltage, InHarm current — measurement numbers | 1-16 groups |
| InHarm voltage, InHarm current — measurement accuracy | Vfund >1%: error <1%; Vfund <1%: error <0.05% of nominal voltage; Afund >3%: error <1%; Afund <3%: error <0.05% of current range |
| HiHarm voltage, HiHarm current — measurement mode | Complies with IEC61000-4-7; the analysis time window is ten cycles |
| HiHarm voltage, HiHarm current — indicator points | 5120 points every 10 cycles |
| HiHarm voltage, HiHarm current — display mode | Waveform, trend charts, histograms |
| HiHarm voltage, HiHarm current — measurement numbers | 1-35 groups |
| HiHarm voltage, HiHarm current — measurement accuracy | Vfund >1%: error <1%; Vfund <1%: error <0.05% of nominal voltage; Afund >3%: error <1%; Afund <3%: error <0.05% of current range |
| Voltage SubHarm, current SubHarm — measurement mode | Complies with IEC61000-4-7; the analysis time window is ten cycles |
| Voltage SubHarm, current SubHarm — indicator points | 5120 points every 10 cycles |
| Voltage SubHarm, current SubHarm — display mode | Waveform, trend charts, histograms |
| Voltage SubHarm, current SubHarm — measurement numbers | 1-50 groups |
| Voltage SubHarm, current SubHarm — measurement accuracy | Vfund >1%: error <1%; Vfund <1%: error <0.05% of nominal voltage; Afund >3%: error <1%; Afund <3%: error <0.05% of current range |
| Voltage/current unbalance (pos, neg) — measurement mode | 3P3W or 3P4W, calculated from the fundamental wave components of the three phases |
| Voltage/current unbalance (pos, neg) — display mode | Waveform, trend charts, histograms |
| Voltage/current unbalance (pos, neg) — measurement accuracy | Voltage unbalance: ±0.2%; current unbalance: ±0.5% |
| Voltage fluctuation — measurement mode | Calculated from the half-wave root mean square |
| Voltage fluctuation — display mode | Waveform, trend charts |
| Voltage fluctuation — measurement accuracy | ±1% |
| IEC flicker — measurement | Short-term P (Pst), long-term P (Plt) |
| IEC flicker — measurement mode | According to IEC61000-4-15, calculates Pst (10 min) and Plt (2 hours) |
| IEC flicker — display mode | Waveform, trend charts |
| IEC flicker — measuring range | 0-20 |
| IEC flicker — measurement accuracy | ±5% |
| Surge current — measurement mode | Recorded when the half-wave RMS current exceeds the set value and the hold time is 10ms-1min |
| Surge current — display mode | Maximum surge current and surge current waveform |
| Surge current — measurement accuracy | 0.10% |
| Voltage swell — criterion | When the half-wave RMS voltage is higher than the set value and the hold time is 10ms-1min, it is judged as a swell |
| Voltage sag — criterion | When the half-wave RMS voltage is lower than the set value and the hold time is 10ms-1min, it is judged as a sag |
| Voltage swell, voltage sag, DIP — measurement accuracy | 0.10% |
| Instrument size | 263mm x 168mm x 65mm |
| Weight | 2 kg |
| Power supply — input voltage | 110V-240V |
| Power supply — adapter output | 15V, 3A |
| Battery | Rechargeable nickel-metal hydride, 4500mAh |
| Battery working time | 4h |
| Battery charging time | 5h (ambient temperature 25°C) |
| Power saving | Adjustable LCD backlight brightness; adjustable standby time |
| Display — size | 112.8 x 84.6mm |
| Display — colors | 260,000 colors |
| Display — resolution | 640 x 480 |
| Display — brightness | Max 350 cd/m2 (typ.), adjustable brightness |
| Display — contrast | 500:1 (typ.) |
| Display — viewing angle | 70/70/50/70 (typ.) (CR ≥10) (left/right/up/down) |
| Storage — type | TF card (built-in) |
| Storage — size | 8G |
| Standard — measurement method | IEC 61000-4-30 |
| Standard — measurement performance | IEC 61000-4-30, level A |
| Standard — flicker | IEC 61000-4-15 |
| Standard — harmonics | IEC 61000-4-7 |
| Safety — standard | GB 4793.1-2007/IEC 61010-1:2001: “Safety requirements for electrical equipment for measurement, control and laboratory use”, part 1: general requirements. Safety level: CAT III 1000 V/ CAT IV 600 V |
| Safety — maximum phase input voltage | CAT III 1000V/CAT IV 600V |
| Environmental conditions — operation | 0°C to +45°C, humidity below 90rh% |
| Environmental conditions — storage | -20°C to +50°C, humidity below 95rh% (non-condensing) |