The HS-28M-N01 is an air quality meter developed to detect PM2.5, PM10, temperature, humidity, air pressure, light, TVOC, O2, carbon dioxide (CO2), carbon monoxide (CO), formaldehyde (CH2O) and other air quality parameters. The transmitter uses imported sensors and computing chips, with high accuracy, high resolution and good stability.
It is widely used in building heating, ventilation and cooling (HVAC) systems, smart homes, schools, hospitals, stations, airports and other sites.
Price on request
No sign-up. You review the list and send it when you are ready.
Torn between two models?
Ask on WhatsAppSaves this product and the next ones you view in this browser, up to eight, for 30 days. You can disable it under “History” in the footer.
History is enabled in this browser. History
The device combines several measuring elements in a single meter with a digital output signal (RS485).
| Property | Value |
|---|---|
| DC power supply (standard) | 10-30V DC |
| Maximum power consumption | 0.5W (24V DC supply) |
| Detection parameters | Temperature, humidity, PM2.5, PM10, air pressure, light, TVOC, CO2, formaldehyde, O3, CO, CH4, O2, SO2, NO2, H2, H2S, NH3 |
| Working environment | Temperature -10 ℃ to 55 ℃; humidity 0 ~ 95% RH, non-condensing |
| Signal output | RS485 (standard Modbus-RTU protocol) |
| Product material | ABS |
| Installation method | Wall or ceiling mounting |
| PM2.5 — measuring range | 0~1000ug/m3 |
| PM10 — measuring range | 0~1000ug/m3 |
| PM10 — resolution | 1ug/m3 |
| PM10 — accuracy | ±10% |
| PM10 — preheat time | ≤2min |
| Temperature — measuring range | -40℃~+120℃ |
| Temperature — resolution | 0.1℃ |
| Temperature — accuracy | ±0.5℃ |
| Humidity — measuring range | 0%RH-100%RH |
| Humidity — resolution | 0.1%RH |
| Humidity — accuracy | ±3%RH |
| Atmospheric pressure — measuring range | 0~120kPa |
| Atmospheric pressure — resolution | 0.1kPa |
| Atmospheric pressure — accuracy | ±0.15kPa (at 25℃ and 75kPa) |
| Illumination — measuring range | 0~200,000Lux |
| Illumination — resolution | 1Lux |
| Illumination — accuracy | ±7% (25℃) |
| TVOC — measuring range | 0~60,000ppb |
| TVOC — resolution | 1ppb |
| TVOC — accuracy | ±8%FS±125ppb |
| Carbon dioxide (CO2) — measuring range | 0~5000ppm |
| Carbon dioxide (CO2) — resolution | 1ppm |
| Carbon dioxide (CO2) — accuracy | ±(40ppm+ 3%F·S) |
| Carbon dioxide (CO2) — preheat time | 2min (available), 10min (maximum accuracy) |
| Formaldehyde (CH2O) — measuring range | 0~5ppm |
| Formaldehyde (CH2O) — resolution | 0.01ppm |
| Formaldehyde (CH2O) — accuracy | ±5%FS |
| Formaldehyde (CH2O) — preheat time | ≥5 minutes |
| Ozone (O3) — measuring range | 0~10ppm |
| Ozone (O3) — resolution | 0.01ppm |
| Ozone (O3) — accuracy | ±6%FS |
| Ozone (O3) — preheat time | ≥5 minutes |
| Oxygen (O2) — measuring range | 0~25%Vol |
| Oxygen (O2) — resolution | 0.1%Vol |
| Oxygen (O2) — accuracy | ±3%FS |
| Oxygen (O2) — preheat time | ≥5 minutes |
| Hydrogen sulfide (H2S) — measuring range | 0~100ppm |
| Hydrogen sulfide (H2S) — resolution | 1ppm |
| Hydrogen sulfide (H2S) — accuracy | ±3%FS |
| Hydrogen sulfide (H2S) — preheat time | ≥5 minutes |
| Methane (CH4) — measuring range | 0~100%LEL |
| Methane (CH4) — resolution | 1%LEL |
| Methane (CH4) — accuracy | ±5%FS |
| Methane (CH4) — preheat time | ≥5 minutes |
| Carbon monoxide (CO) — measuring range | 0~1000ppm |
| Carbon monoxide (CO) — resolution | 1ppm |
| Carbon monoxide (CO) — accuracy | ±3%FS |
| Carbon monoxide (CO) — preheat time | ≥5 minutes |
| Nitrogen dioxide (NO2) — measuring range | 0~20ppm |
| Nitrogen dioxide (NO2) — resolution | 0.1ppm |
| Nitrogen dioxide (NO2) — accuracy | ±3%FS |
| Nitrogen dioxide (NO2) — preheat time | ≥5 minutes |
| Sulfur dioxide (SO2) — measuring range | 0~20ppm |
| Sulfur dioxide (SO2) — resolution | 0.1ppm |
| Sulfur dioxide (SO2) — accuracy | ±3%FS |
| Sulfur dioxide (SO2) — preheat time | ≥5 minutes |
| Hydrogen (H2) — measuring range | 0~1000ppm |
| Hydrogen (H2) — resolution | 1ppm |
| Hydrogen (H2) — accuracy | ±3%FS |
| Hydrogen (H2) — preheat time | ≥5 minutes |
| Ammonia (NH3) — measuring range | 0~100ppm |
| Ammonia (NH3) — resolution | 1ppm |
| Ammonia (NH3) — accuracy | ±2%FS |
| Ammonia (NH3) — preheat time | ≥5 minutes |