DC Voltage and Current

EasyLog EL-USB-4 Current Data Logger with USB (4-20mA DC)

Reference
EL-USB-4

This standalone data logger records more than 32,000 readings over a 4-20mA DC measurement range. It is supplied with a cap featuring a pair of screw terminals and measurement leads terminating in crocodile clips.

Easily set up the logger and view downloaded data by plugging the unit into a PC’s USB port and using the free EasyLog software provided. Data can then be graphed, printed and exported to other applications for detailed analysis. Supplied with a ½ AA battery and wall mount clip.

Price on request

No sign-up. You review the list and send it when you are ready.

EL-USB-4

Torn between two models?

Ask on WhatsApp

Overview

Specifications

  • Measurement range: 4 to 20mA DC
  • Internal resolution: 0.05mA DC
  • Accuracy: ±1%
  • Input impedance: 110 ohms
  • Logging rate: user selectable between 1 second and 12 hours
  • Operating temperature range: -35 to +80°C
  • Battery life: 3 years (at 25°C and 2 second logging rate)
  • Readings: 32,510
  • Dimensions: 98 x 26.8 x 26.8 mm

Application

The EL-USB-4 is suitable for a wide variety of applications, including:

  • Outside environmental data

Related products