AC Voltage and Current

FU2200A Multifunction Electric Power Meter with Data Logger

Reference
FU2200A

Made by GFUVE, the FU2200A is a three-phase multifunction power and energy meter with Ethernet and a built-in data logger, offering excellent value for monitoring power and energy management systems. It can serve as a data-gathering device in intelligent power distribution or plant automation systems.

Every monitored value is available through a standard digital RS485 port running the Modbus RTU protocol.

What it measures

  • Energy

Price on request

No sign-up. You review the list and send it when you are ready.

FU2200A

Torn between two models?

Ask on WhatsApp
  • Power supply (AC/DC) AC85-400V / DC85-330V
  • Energy computation Forward and reverse active energy; reverse reactive energy
  • Measuring range 0-400V, 0-6A, 45-65Hz, -1 ~ 0 ~ 1
  • Maximum demand Ia, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutes
  • Display Blue backlit LCD, 5 digits and 4 operation keys
  • Memory 2M onboard, expandable to 16M; logging interval 1min to 60min (default: 15min)

Overview

PC software and a data logger function come with the meter, and the end user can set the logging interval anywhere from 1min to 60min. Data can be read on a PC or shared over the Internet LAN, and the meter also measures harmonics.

Highlights

  • True-RMS measurement of all parameters
  • ANSI and IEC 0.2 accuracy class
  • Power quality analysis
  • 4 quadrant energy
  • 2MB onboard memory, expandable to 16M
  • Data logging
  • High-speed RS485, plus an optional Ethernet port
  • Optional measurement of individual harmonics from the 2nd to the 63rd
  • TOU with 4 tariffs, 6 seasons and 6 schedules
  • Three years warranty
  • PC management software and web browsing of data

Typical uses

  • Metering of distribution feeders, transformers, generators, capacitor banks and motors
  • Medium and low voltage systems
  • Commercial, industrial and utility sites
  • Power quality analysis
  • Data logging
  • Monitoring systems

Electrical parameters

  • Power supply (AC/DC): AC85-400V / DC85-330V; consumption <4VA
  • Measured quantities: phase-to-neutral voltage (Ph-N), phase-to-phase voltage (Ph-Ph), current, frequency, PF, active power (W), reactive power (Q), apparent power (S), and optional 2nd to 63rd harmonics
  • Harmonics: total harmonic ratio of phase voltage and of current; 2nd to 63rd harmonic ratio of phase voltage and of current
  • Maximum and minimum values: voltage, current, frequency, active, reactive and apparent power, demandP, demandQ, demandS
  • Energy computation: forward and reverse active energy, reverse reactive energy
  • Measuring range: 0-400V, 0-6A, 45-65Hz, -1 ~ 0 ~ 1
  • Accuracy: voltage, current and active power 0.5%RD±0.05%FS; reactive power 1.5%RD +0.05%FS; apparent power 0.5%RD +0.1%FS; power factor 0.5%RD; frequency 0.05%RD; active energy 0.5%
  • Maximum demand: Ia, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutes
  • Display: blue backlit LCD with 5 digits and 4 operation keys
  • Communication: RS-485 interface port with 32 (128) networking; Modbus-TCP/IP and SNMP protocols; Ethernet 10/100M port (RJ45)
  • Memory: 2M onboard, expandable to 16M. The end user sets the logging interval from 1min to 60min, with 15min as the default. Data is read on a PC, and the software lets you choose which data to display and store.
  • Programmable: measuring system 3P4W/3P3W etc.; transformation ratio PT 1-10000 and CT 1-10000
  • Energy pulse: active and reactive energy pulse output with selectable pulse parameters; range 0.1-10000kWh/kvarh; dry contact output (1Ax100V)
  • Connection modes: 3P4W, 3P4W BAL, 3P3W, 3P3W BAL, 1P3W, 1P2W
  • Baud rate: 1200-57600, standard 38400

Mechanical and environmental data

  • Dimensions (L x W x H): 96 x 96 x 12.8 mm
  • Panel mounting; cutout 92x92mm; installation depth 51mm
  • Temperature: -5 to +50 °C
  • Humidity: 20%-95%RH, non-condensing
  • Warranty: three years

Accuracy, resolution and ranges by quantity

Each line gives, in order, accuracy, resolution, measuring range and the range shown on the display.

  • Voltage: 0.20%; 0.01V; 0-400V; 0.5-500kV
  • Current: 0.20%; 0.01mA; 0-6.5A; 5mA-50000A
  • Active power: 0.50%; 0.2W; 0-2400W/phase; -9999MW to +9999MW
  • Reactive power: 2%; 0.2var; 0-2400var/phase; -9999Mvar to +9999Mvar
  • Apparent power: 0.50%; 0.2VA; 0-2400VA/phase; 0-9999MVA
  • Active demand: 0.50%; 0.2W; 0-2400W/phase; -9999MW to +9999MW
  • Reactive demand: 2%; 0.2var; 0-2400var/phase; -9999Mvar to +9999Mvar
  • Apparent demand: 0.50%; 0.2VA; 0-2400VA/phase; 0 to 9999MVA
  • Power factor: 0.005; 0.0001; -2; -2
  • Frequency: 0.01Hz; 0.01Hz; 45.000-65.000Hz; 45.000-65.000Hz
  • Active energy: 0.5% or 0.2% (option); 0.001kWh; 0-999999.999kWh; 0-99999999.9kWh
  • Reactive energy: 2%; 0.001kvarh; 0-999999.999kvarh; 0-99999999.9kvarh
  • Apparent energy: 0.50%; 0.001VAh; 0-999999.999kVAh; 0-99999999.9kVAh
  • Phase angle: 0.1°; 0.01°; 0-359.99°; 0-359.99°
  • Unbalance: 2%; 0.01%; 0-300.00%; 0-300.00%
  • PT ratio: resolution 1; displayed 1-10000
  • CT ratio: resolution 1; displayed 1-10000
  • Address code: resolution 1; displayed 1-253