Light, Solar Radiation and PAR

LightScout UV Radiation Sensor (UVA and UVB, 250–400 nm) for WatchDog Stations

Reference
3676I

Fixed-mount external sensor from Spectrum Technologies that continuously logs ultraviolet radiation between 250 and 400 nm (UVA and UVB) in µmol m⁻² s⁻¹. It connects to WatchDog weather stations and data loggers and to the portable LightScout External Light Sensor Reader.

What it measures

  • Light Intensity

Price on request

No sign-up. You review the list and send it when you are ready.

3676I

Torn between two models?

Ask on WhatsApp (opens in a new tab)
  • Manufacturer Spectrum Technologies
  • Spectral range 250 to 400 nm (UVA and UVB)
  • Measuring range 0 to 200 µmol m⁻² s⁻¹
  • Accuracy ±5%
  • Excitation voltage 3.0 to 5.0 VDC
  • Sensor output 0 to 2.0 V

Overview

Continuous ultraviolet measurement, in the field or in the greenhouse

The Spectrum Technologies LightScout UV radiation sensor is designed to stay installed and log ultraviolet radiation over weeks and whole seasons, not just spot readings. It covers 250 to 400 nm, including the UVA and UVB bands, and reports photon flux density (µmol m⁻² s⁻¹), the same quantity used for photosynthetically active radiation (PAR). That makes it easy to compare UV and PAR in the same dataset.

Connected to a WatchDog station or logger, the sensor becomes part of the station's record: every reading is stored alongside temperature, humidity, rainfall and the other site variables.

Where it helps

  • Plant physiology research: relate UV dose to pigmentation, photochemical stress, plant health and fruit and leaf quality.
  • Greenhouses: compare UV inside and outside the cover to see how much plastic films, glass and shade screens let through, and track how the material degrades over time.
  • Growth chambers and rooms: check the UV delivered by lamps and fixtures.
  • Agrometeorology and teaching: add UV radiation to the data series of an experimental station.

Why choose this sensor

  • Automatic logging: no repeated manual readings, just a continuous series.
  • Direct WatchDog integration: plugs into the external port of the station or logger and is programmed with SpecWare software.
  • UV light hours: SpecWare calculates UV light hours under "Reports".
  • Dual use: with the mounting bracket removed, the same sensor can be read on the portable LightScout External Light Sensor Reader in "UV A&B" mode.
  • Linear analog output: 0 to 2.0 V, converted directly to µmol m⁻² s⁻¹.

Technical specifications

Feature Value
Manufacturer Spectrum Technologies
Spectral range 250 to 400 nm (UVA and UVB)
Measuring range 0 to 200 µmol m⁻² s⁻¹
Accuracy ±5%
Excitation voltage 3.0 to 5.0 VDC
Sensor output 0 to 2.0 V
Conversion µmol m⁻² s⁻¹ = V × 100
Data cable 6 ft (about 1.8 m)
Mounting 1" to 1¼" mast or pipe, U-bolt included
Manufacturer warranty 1 year against defects in materials and workmanship

Compatibility

  • WatchDog 3000 and 2000 Series weather stations
  • WatchDog 1000 Series micro stations
  • Portable LightScout External Light Sensor Reader

Installation and use

  1. Pick a spot that represents the light the plants receive, above or within the canopy, within reach of the station's external port.
  2. Fix the sensor to a 1" to 1¼" mast or pipe with the U-bolt.
  3. Use the adjustment screws to center the bubble in the level indicator.
  4. Make sure no other sensor or structure shades it.
  5. Plug the data cable into the external port of the WatchDog station or logger.
  6. In SpecWare, set the port to log UV light. See the SpecWare manual for launch and readout steps.
  7. Inspect the sensor often to keep it level and clear of obstructions.

To use it with the portable reader, loosen the thumbscrews, remove the mounting bracket (keep the parts), plug the sensor into the reader and select "UV A&B".

What's included

  • LightScout UV radiation sensor
  • 6 ft (about 1.8 m) data cable
  • Mounting bracket with level indicator and U-bolt

FAQ

How is this different from the handheld LightScout UV meter?
This is a fixed-mount external sensor for continuous logging on WatchDog stations and loggers. The handheld meter has its own display and is meant for instant field readings.

Why µmol m⁻² s⁻¹ instead of W/m²?
Plant photobiological responses depend on the number of photons absorbed. Measuring in µmol m⁻² s⁻¹ puts UV in the same unit as PAR. Converting to W/m² depends on the source spectrum and is not provided by the manufacturer.

Does it need a battery?
No. The sensor takes its excitation voltage (3.0 to 5.0 VDC) from the device it is connected to.

Can I use it with another brand of data logger?
The sensor has a 0 to 2.0 V analog output and 3.0 to 5.0 VDC excitation, but the manufacturer only documents use with WatchDog and the LightScout reader. Contact our team before integrating it into another system to confirm the connector and wiring.

Need help building a station that measures UV, PAR and solar radiation? Contact the HEN Sistemas team and request a quote.